7 Scanner Projector Adjustment
•This procedure explains how to configure the projector. This should be made one time after
installation. It may be necessary to do this procedure after a long pause (several weeks) or if the
scanning results shows “strange” behavior.
•Before starting the configuration, make sure the projector is on, connected and that the computer is
correctly configured. To help during the procedure, place a white paper or use the Calibration Plate
(white side) in front of the projector (inside the scanner). All commands use the remote control. For
ease of understanding, the buttons were numbered on the picture below; these numbers are noted in
the text.
•Note: Once started, the whole procedure must be done until the end.
I Factory Default
•If necessary, turn the projector on, using the “Power” button (1)
•Press the “Menu” button (2) of the remote control
•Press ▼(5) to get to the «Set Up» Menu
•Press ► (6) to enter the «Set Up» Menu
•Press ▼ (5) until you reach «Factory Default»
•Press ►(6) to enter this function
•Press ►(6) to get on «OK»
•Press the “Enter” button (7)
II Picture Menu
•Press the “Menu” button (2)
•Press ▼(5) once to get to the «Picture» menu.
•Press ►(6) to enter the «Picture» menu
•Press ▼(5) to select «Digital NR» (Noise Reduction)
•Press ►(6)
•Select «Off»
•Press ◄ (4) to come back to the main menu.
III Input Menu
•Press ▲ (3) to come to the menu «Input”
•Press ► (6) to go to «Source List» , then ►(6) again
•Select «PC» and press the “Enter” button (7)
D10x_Setup_Guide_20111202 Page 7 of 8 January 10, 2012