can only be stopped after working for at least 3 minutes; the compressor can only be re-
started 3 minutes after it stops;
3. If works under low temperature, the dehumidifier may judge the system
temperature automatically and defrost automatically; when defrosting, the indicator
of defrosting is light, the fan works and compressor stops working.
4. The system has auto memory. When all the mode setting has been finished, if there is
sudden power cut during operation, or the power jack slips out, the system may store
the current status before the power is cut and enter the operation mode before power cut
automatically after power is supplied;
5. Range for humidity is 20%-90%;
6. Auto detection of temperature/humidity failure:
a. When the system detects that temperature sensor exceeds the limited range, the system
enters mode of temperature sensor failure. Under this mode, LCD displays temperature
failure code “E1”, the system works in circle of dehumidification for 30 minutes and
defrosting for 15 minutes;
b. When the system detects that humidity sensor exceeds the limited range, the system
enters mode of humidity sensor failure. Under this mode, LCD displays humidity
failure code “E2” and the system enters continuous dehumidification.
c. After temperature/humidity sensor failure is eliminated, the system works normally.
7. Water Tank Full State: No matter machine is on or off, when the water tank is full, as
long as the signal of water is full for constantly for 3seconds, the system enter the
model of “water is full and stop the machine”, under this mode, the light of water tank
is full flashing, the compressor and fan stopped work and the buzzer buzzes constantly
for 20 times
Notices:
1. If the set humidity is higher than the actual humidity, the dehumidifier stops working;
2. During dehumidification, after the compressor starts working, the fan and compressor
can only be stopped after working for at least 3 minutes; the compressor can only be re-
started 3 minutes after it stops;
3. If works under low temperature, the dehumidifier may judge the system
temperature automatically and defrost automatically; when defrosting, the indicator of
defrosting is light, the fan works and compressor stops working.
4. The system has auto memory. When all the mode setting has been finished, if there is
sudden power cut during operation, or the power jack slips out, the system may store the
current status before the power is cut and enter the operation mode before power cut
automatically after power is supplied;
5. Range for humidity is 30%-90%;
6. If the dehumidifier is going to be spared for a long time, please unload the power cord
or cut the power.
7. Auto detection of temperature/humidity failure:
d. When the system detects that temperature sensor exceeds the limited range, the system
enters mode of temperature sensor failure. Under this mode, LCD displays temperature
failure code “E1”, the system works in circle of dehumidification for 30 minutes and