InfiRay DTC300 Manuale utente

DTC300
Dual-spectrum Accurate Temperature Measurement Camera
Quick Start Guide V1.0.0
IRay Technology Co., Ltd.

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 1 -
©IRay Technology Co., Ltd. 2018 Reserve all the right. All in this manual including texts, pictures,
diagrams and other contents belong to IRay Technology Co.,Ltd (Hereinafter referred to as “Our
company”or “IRay Photoelectric”). Without the written permission, no one shall copy, photocopy,
translate or disseminate all or part of this manual.
This manual is used as a guide. The photos, graphics, diagrams and illustrations provided in the manual
are only used to explain, which may be different from the specific product. Please refer to the real object.
We try our best to make sure the contents in this manual are accurate. We do not provide any
representations or warranties in this manual.
If you need the latest version of this manual, please contact us. IRay Photoelectric recommends that you
use this manual under the guidance of professionals.
Version History
Version
Date
Description
V1.0.0
2020-3-26
Initial version

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 2 -
Content
1. Overview................................................................................................................ - 3 -
2. Product Performance.............................................................................................. - 4 -
3. Installation Guide................................................................................................... - 6 -
3.1 Product and Accessory List ......................................................................................................................- 6 -
3.2 Mounting and Connecting Thermal Camera.............................................................................................- 6 -
3.3 Site Layout Solution.................................................................................................................................- 8 -
3.4 Site Installation and Layout Considerations.............................................................................................- 9 -
4 . Quick Start of Client ........................................................................................... - 10 -
5. Trouble Shooting...................................................................................................- 11 -
6. Maintenance..........................................................................................................- 11 -
6.1 Notice .....................................................................................................................................................- 11 -
6.2 Cleaning and Maintenance .....................................................................................................................- 12 -
6.3 Safety Codes...........................................................................................................................................- 12 -
7. After Sales Service............................................................................................... - 13 -
8. Company Information.......................................................................................... - 13 -

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 3 -
1. Overview
DTC300 is a dual-spectrum accurate temperature measurement camera, which is developed for the
body temperature screening and has the characteristics of non-touch, high sensitivity and flexible
installation etc. It can be used for quick temperature detection, and trigger the alarm system when the
pedestrian who has abnormal body temperature passes through the orderly channel in public place
(such as hospital, enterprise, school, community, mall and supermarkt etc.), with its integrated high
precise infrared temperature measurement camera and accurate face recognization technology. It
roles as a quick tool and provides accurate body temperature data during the period of fighting with
epidemic.
Figure 1 Product photo

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 4 -
2. Product Performance
Table 1 Parameters of Product
Model
DTC300
Detector Parameters
Detector type
VOx Uncooled Infrared FPA Detector
Resolution
384×288
Pixel pitch
17μm
Response spectrum
8~14μm
Lens Parameters
Focal length
9.7mm
Focus type
Athermal
FOV(Horizon×Vertical)
37.2°×28.3°
IFOV
1.7mrad
Visible Light Parameters
Resolution
1920×1080
Focal length
4.4mm
FOV
90°
Temperature Measurement Function
Measuring range
0~60℃
Measuring accuracy(1)
±0.5℃@target temperature 33℃~42℃ (without BBS)
±0.3℃@target temperature 33℃~42℃ (with BBS)
Effective measuring distance
1~3m
Interface
Power supply
USB ×2(5V DC)
Communication interface
USB
Communication protocol
UVC(USB Video Class)
Physical Parameters
Dimension
110mm×75mm×56mm
Environment Adaptation

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 5 -
Operating temperature
-10℃~50℃
Storage temperature
-20℃~+65℃
Humidity
5~95%,no condensation
Software Function
Face recognition
Support intelligent face recognition
Secondary development
Provide Windows SDK and development manual
Note:
(1) .Please refer to GB/T 19665-2005 for the test conditions without BBS ;
The environment temperature should be 16℃~32℃ for the accurate temperature measurement with BBS.(Room
temperature without mutation)

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 6 -
3. Installation Guide
3.1 Product and Accessory List
Before installation, please make sure that the equipment in the package is intact and all parts are
available.
Other accessories:
Computer performance: CPU higher than Intel i5-9500T/ at least 8G memory/ 64-bit win10
system(version higher than V201709) / Support Gigabit Ethernet/ Graphic card supports
GPU and Vulkan/ Include at least 3 USB interfaces;
Display: 1920 ×1080 resolution;
Standard package
DTC camera ×1
Type-C cable ×1
module connection cable ×1
High precise blackbody ×1
Tripod ×2
Extension shaft ×4

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 7 -
3.2 Mounting and Connecting Thermal Camera
As shown in figure 2, there is a 1/4-20UNC hole at the bottom of camera, which is used to mount
camera to a adapter bracket or quick shoe.
Figure 2 Bottom diagram of DTC camera
Take the thermal camera mounted on a tripod as an example. Please find the specific installing steps
as following.
Install the quick shoe at the bottom of camera with a 1/4 screw, and install the camera on the
PTZ of tripod, locking the screw at side. As shown in figure 3.
Figure 3 Installing diagram
Plug Type-C data cable to the left interface, and then plug the module cable to the right
connector. As shown in figure 4.
Figure 4 Connecting diagram of camera

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 8 -
Plug the three USB interfaces at the other end to the computer which has installed DTS PC client.
As shown in figure 5.
Figure 5 Connecting diagram of PC
After powering on computer, the camera startup automatically with the sound of shutter working.
Please wait for 40 minutes before performing measuring to ensure the measurement accuracy.
3.3 Site Layout Solution
1)、Reference layout
Refer to Figure 6 for the layout plan in a wide space area. The external reference blackbody is
placed directly in front of the infrared camera and made it observable in the imaging field of
view. Pedestrians need to be guided and make sure all of them can be observed with the thermal
imaging camera.
Figure 6Arrangement of infrared human body thermal imaging camera

DTC300 Accurate Dual-spectrum Temperature Measurement Camera V1.0.0
责任 进取 敏行 合作
400-998-3088 www.iraytek.com
IRay sensing® All Insight
- 9 -
Installation direction and height of camera
The installation distance and height of the camera should be arranged according to the actual
situation, the recommended distance is 2m, and the installation height should ensure that all of the
observed pedestrians can appear in the field of view.
Reference blackbody layout
As shown in Figure 7, adjust the direction and position of the infrared human body thermal
imaging camera and the reference black body so that the reference black body appears in the 2/3
central area of the camera market and shall not be shielded by pedestrians.
Figure 7 Infrared imaging on PC
Environmental requirements
The infrared temperature measuring camera is arranged in an environment where the
temperature is relatively constant and there is no direct sunlight, to avoid temperature measurement
errors caused by the temperature changing environment affecting the human skin surface temperature.
According to the above installation requirements, the following installation methods can be used to
install equipment in halls and aisles.
3.4 Site Installation and Layout Considerations
1)、Avoid placing it at the entrance with airflow disturbance
Avoid the temperature rise and fall caused by the air surface disturbance of the skin of the
person being tested, which will affect the false alarm or miss alarm of the infrared temperature
measuring camera.
参考黑体
出现区域
人
People
Reference blackbody
appearance area
Altri manuali per DTC300
1
Indice
Altri manuali InfiRay Macchina fotografica digitale