Introduction
10 Infoblox Installation Guide
System, Environmental, and Power Specifications
System specifications describe the physical characteristics of each appliance. Environmental specifications
describe the temperature and moisture limits it can withstand. Power specifications describe the electrical range
within which the appliance circuitry can operate.
System Specifications
•Form Factor: 2-U rack-mountable appliance
•Dimensions: 3.44” H x 17.54” W x 27.5” D (8.75 cm H x 44.55 cm W x 69.85 cm D)
•Weight: Approximately 61.00 pounds (27.66 kg)
•Ethernet Ports: MGMT, HA, LAN1, LAN2 – auto-sensing 10Base-T/100Base-T/1000Base-T
•Serial Port: DB-9 (9600/8n1, Xon/Xoff)
•USB Ports: Two USBs 2.0/1.1 compliant
•LCD Panel: LCD (liquid crystal display) with input buttons
Environmental Specifications
•Operating Temperature: 41 to 95 degrees F (5 to 35 degrees C)
•Storage Temperature: -13 to 158 degrees F (-25 to 70 degrees C)
•Operating relative Humidity: 10% to 90% (non-condensing)
Electrical Power Specifications
•DC Power Supply: 48v 750W GRND TERM, RING, VIN 12-10 AWG #10
—Nominal Input Voltage: 48VDC
—Nominal Input Current: 9.6A
—Maximum Power Draw: 460W
LAN2 Port A 10/100/1000-Mbps gigabit Ethernet port that is used for scan interface connections
to managed networks. You can enable the LAN2 port and define its use through the GUI
after the initial setup. For related information, see Configuring Scan Interfaces on page
40 of the Network Automation Administrator’s Guide, Release 6.9.
USB Ports Reserved for future use.
Power Supplies Each of the two redundant power supplies has a power outlet for connecting the
appliance to a standard AC power source.
Power Supply LEDs Green = Normal
Off = System is off or power supply has failed.
UID LED Turns blue to indicate the system is currently being interacted with in the rack. Turned on
by pressing the UID button on the front panel. See Table 1.
Component Description