Innes DMB400 Manuale utente

User Manual
DMB400
4.10.11 001A
1

Legal Notice
User Manual DMB400 4.10.11 (001A_en)
© 2017 Innes SA
Rights and Responsibilities
All rights reserved. No part of this manual may be reproduced in any form or by any means whatsoever without the written permission of the publisher. The products
and services mentioned in this document may be trademarks and/or trademarks of their respective owners. The publisher and the author do not pretend to these
brands.
Although every precaution has been taken in the preparation of this document, the publisher and the author assumes no responsibility for errors or omissions, or for
damages resulting from the use of the information contained in this document or the use of programs and source code who can accompany it. Under no circumstances
can the publisher and the author be held responsible for any loss of profits or any other commercial prejudice caused or that would have been caused directly or
indirectly by this document.
Product information
The conception and specifications of the product may change without prior notice, and this applies to hardware, embedded software and this guide. Consumable items
accessories may slightly differ than herein described as INNES is depending on the evolutions of its suppliers. This document contains confidential information; it can’t be
disclosed to any third parties without prior written authorization of INNES.
Safety instructions
Please read carefully the following instructions before switching the product on: - WARNING! Correct fitting and installation is of the utmost importance. Incorrect fitting
and/or installation may result in personal injury or loss. INNES disclaims all liability, of whatever kind, if the product is assembled, fitted and/or installed in an incorrect
manner. - Do not use the product near a water supply. - Do not pour anything on the product, like flammable liquids or material. - Do not expose the product to direct
sun, near a heating source or a dust nor vibrations. - Do not obstruct holes, to be sure that air flows freely around the product. - Switch off the product during a storm. -
Do not open the product in any circumstances.
Guarantee terms
INNES products are eligible for a warranty to cover genuine manufacturing defect for 3 years. Product failure occurring as the result of factors that do not constitute
genuine manufacturing defect are not covered under the terms of the warranty and any repairs of this nature would be chargeable. For example: Inappropriate
maintenance action, a non-authorized modification, a not specified environment utilization (see ‘Safety instructions’), or if the product has been damaged after an
impact, a fall, a bad manipulation or a storm consequence, an insufficient protection against heat, moisture or frost. This warranty is not transferrable. In addition, any
repairs carried out by non-authorized personnel will invalidate the warranty.
WEEE Directive
This symbol means that your end of life equipment must not be disposed of with household waste but must be deposited at a collection point for waste electrical and
electronic equipment or to your reseller. This will benefit the environment. In this context, a system for collecting and recycling has been implemented by the European
Union
2

1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
Table of Contents
Introduction
Getting started with the device
LEDs behaviour
Connectors pin-out
Technical specifications
Troubleshooting
Conformities
Contacts
3

1.1 Introduction
This manual explains how to setup your device DMB400.
Recommendations and warnings
This device is designed to be used inside a building.
This device is intended to work with the supplied power supply unit. This power supply unit must be connected to a mains socket conforming to standard NF C 15-100. If
the AC power cable is damaged, it must be replaced. It is possible to order a replacement mains unit by sending a request to the email address [email protected].
This device is a Class A device. In a residential environment this device may cause radio interference. In this case, the user is asked to take appropriate measures.
Content of the package
Item Feature
Device DMB400 with Gekkota OS embedded
Power Supply Unit 12V Power Supply unit with cable of 1.2m
Label PSN (Product Serial Number) on the packaging and on the device
4

1.2 Getting started with the device
Front face
1 Antennas
2 Power supply connector
3 Audio connector
4 USB2 3.0 connector
5 RS232 DTE connector
6 HDMI output connector
Rear face
7 Antennas
8 Power supply Red Led
9 Status Green Led
10 LAN RJ45 connector
11 Infrared connector
12 HDMI input connector
13 USB1 2.0 connector
Device fixture
VGA
100
200
4,5 mm
7,5 mm
Device dimensions
ANT 3 ANT 4
HDMI1 OUT
RS232 DTE
AUDIO
DC IN USB2
DMB400
1
2
3
4
5
6
1
HDMI IN
ANT 1 ANT 2
IR
LAN USB1
STATUS
POWER
7
8
9
10
11
12
13
7
5

39 mm
190 mm
100 mm
200 mm
134 mm
ANT 3 ANT 4
HDMI OUT
RS232 DTE
AUDIO
DC IN USB2
DMB400
HDMI IN
ANT 1 ANT 2
IR
LAN USB1
STATUS
POWER
Labeling
The model of the device, its power supply characteristics, its serial number (PSN) as well as its MAC address are written on a label stuck on the case. Additional tags may
be present in case of built-in options.
☛ The serial number of the device can be requested in case of technical support.
6

Device start-up step
Testcard
The device is configured at the factory to start on the test pattern. The chart displays important information to assist in configuration:
Disable the testcard by using the WebUI.
Step 1 (T0=0s)
Device start-up initialisation
Step 2 (T~23s)
Device start-up finalisation
This phase duration is depending on some variable values
(like NTP), some network access duration or some data
checking (check-disk)
Step 3 (T~44s)
Nominal mode
During this step, the device has to play the content.
When firmware upgrade process occured, in
case DNS valid & NTP server inactive, it takes
~2min50s.
>
7

1.3 LEDs behaviour
LED POWER behaviour (power on device)
State Information
Red OK: Power supplied
Off Error : Power supply issue ¹
LED LAN behaviour (power on device)
State Information
Off There is no network traffic on the Ethernet connector
Blinking The blinking frequency is indicating the data rate on Ethernet connector
LED STATUS behaviour depending on device start-up steps
• Step 1 : Device start-up initialisation
State Information
Green: continuous OK
Always Off Error : Power supply issue ¹
• Step 2 : Device start-up finalisation
State Information
Off OK. This step duration can be from several seconds to several minutes.
Green blinking: 1 second duration flash and periodicity every 2 seconds Error: Boot issue ¹
• Step 3 : Nominal mode
State Information
Green blinking: 1 very short flash
(150 ms) and periodicity every 4
seconds
OK
Green blinking: 2 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: Fail Soft Mode Level 1
De fréquents redémarrages de l'appareil ont été constatés (par exemple, 4 redémarrages en 10 minutes).
Un message est affiché à l'écran «Mode dégradé: attente d'un nouveau contenu».
L'instabilité a été causée probablement par un média de votre contenu qui n'est pas encore supporté par l'appareil. En
conséquence, pour prévenir de futur redémarrages inutiles, le contenu a été invalidé. Le message indique qu'une nouvelle
publication est requise pour jouer à nouveau le contenu. ²
Green blinking: 3 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: Fail Soft Mode Level 2
De fréquents redémarrages de l'appareil ont été constatés (par exemple, 4 redémarrages en 10 minutes).
Un message est affiché à l'écran «Mode dégradé: attente d'un nouveau contenu».
Le contenu a été effacé et des valeurs de préférences utilisateur ont été restaurées. Le message indique qu'une nouvelle
publication est requise pour jouer à nouveau un contenu. ²
Green blinking: 4 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: Check disk
The device has detected memory corruption on content storage. The media storage is being repaired. This repair step is
called Check-Disk and its duration can be several minutes. During this step, a message “checking the file system of data
partition in progress” is displayed on screen. ³
Green blinking: 5 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: errors on system partition
The user has to connect to device WebUI, go to Maintenance > Tools menu, and press button Format or Repair to solve the
problem. ³
Green blinking: 6 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: a firmware update is pending
During this phase, no content is played on the device, do not switch OFF the device.
Green blinking: 7 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Erro: write problem on the storage
For an unknown reason, your storage space isn't usable any more. ³
Off Error. ¹
¹ If the problem persists despite an appropriate power-supply, contact INNES technical support.
² If the problem persists, it is advised to find out the media not supported yet by the system and remove it from content.
³ If the problem persists after a partition repair, contact INNES technical support.
8

1.4 Connectors pin-out
Power supply connector (12VDC-1.2A)
+
AUDIO
DC IN
DMB400
Lan connector
Ethernet RJ-45. 10/100/1000 BaseT. It is recommended to use shielded cables.
IR
LAN
STATUS
Stereo jack 3.5mm L+R audio cable connector
It is recommended to use cables whose length is less than 3 meters.
GND
R
L
AUDIO
DC IN
DMB400
Video output connector (HDMI 2.0)
This connector is used to connect a screen or video projector.
1 2 345
678 9
ANT 4
HDMI1 OUT
RS232 DTE
RS232 DTE connector
It is recommended to use cables whose length is less than 3 meters.
1 2 345
678 9
RXD TXD GND
CTS
RTS
ANT 4
HDMI1 OUT
RS232 DTE
Connector pin-out
N° Function
1 CD
2 RXD
3 TXD
4 DTR
5 GND
6 DSR
7 RTS
8 CTS
9 -
9

Video input connector (HDMI 1.4)
HDMI IN
ANT 2
IR USB1
GPIO1/IR Jack connector 3.5mm
321
HDMI IN
ANT 2
IR USB1
N# Function
1 3.3V
2 GPIO1/IR
3 GND
Electrical features
Vin min Vin max VOH min VOL max VIH min VIL max
GPIO1 -0.5V 3.6V 2.9V 0.4V 2.0V 0.8V
⚠
• The 3.3V pin must not serve has power supply, but rather of a reference voltage.
• It is not recommended to hotplug/unplug GPIO1 connector, it could provoke a failure of device.
• During boot, the GPIO1 is configured in input during some seconds. And then after the system startup, the GPIO1 is operational.
• The GPIO has a weak pull-up.
Principle schematics for several use cases
3 wires input configuration :
3.3V
GPIO_in
DMB400
switch
Input
Output configuration :
3.3V
GPIO_out
DMB400
Logic gate, transistor or opto-coupler