496332 Issue 1 3 of 22
of the seven circuit attributes, (Attributes do not apply to P.A., Technical
Alarm or 24 hour circuits).
The main control panel is provided with outputs suitable for connection to a
printer or a completely programmed mimic diagram system. The system will
accept a plug-in digital communicator (fast format only) or a direct-line
interface, which can also be used to connect the Series 9500 to “Red Care”
or “ABC” (Alarms by Carrier).
Technical Specification
Zones 0-320.
Display 32 Character “Supertwist” LCD.
Expansion By line interface modules of up to 5 circuits
per LIM.
BS 4737 Full Specification.
Log 450+ events ( Date andTime ).
Panel Siren No.
Internal Siren 9040 4 max.
Dimensions Panel h x w x d 290 x 400 x 10mm.
Dimensions Keypad h x w x d 180 x 110 x 40mm.
Weight Panel 4.6 Kg, Keypad 500g.
Battery 6 Ah.
Communicator
Output Plug-on STU/ 9058/9056 by using the 9578.
Signalling Conversion Interface.
Plug-on Interface 9576, 9576-01.
Outputs Bell relay contacts,
Strobe relay contacts.
Quiescent Current Ratings
12 Volt Power Quiescent: Panel 165mA, Keypad 50mA.
12 Volt AUX Output Not available unless detector power.
requirement less than 150 mA.
9500 Control Panel 165mA.
9558 Communicator 10mA.
9525 Remote Keypad 50mA.
9505 Standard LIM 10mA.
9506 Bare LIM 10mA.
9510 End Of Line LIM 10mA.
9508 Shunt LIM 10mA.
9509 Controller 12mA.
9500 Technical Specification