Innovative Dehumidifier IW-25-4 Manuale utente

1
!
Installation and Operation Manual
IW-25-4 Dehumidifier
In-Wall'Solution' ' ' ' ' ' ' ' ' ' ' ' ' ' On-Wall'Solution'
Please Read and Save These Instructions
AlorAir Solutions, Inc
Innovative!Dehumidifier!Systems,!LLC.!
' 6260'Ocean'Highway'17'West'Ocean'lsle'Beach,'28469!
910-579-DEHU' '
910-579-3348'
www.HumidityHappens.com!

2
Table of Contents
Safety'Notes...................................................................................................................................' 2'
Identification.................................................................................................................................'.' 3'
Electrical'Supply.............................................................................................................................' 3'
Principle'of'Operation....................................................................................................................' 3'
Dehumidifier'Diagram....................................................................................................................' 4'
Dimension'Diagram.........................................................................................................................' 5'
Dehumidifier'Installation'General' ' ' ' ' ' ' ' ' ' ' ' ' ' 6'
' In-Wall'Solution'Only' ' ' ' ' ' ' ' ' ' ' ' ' ' ' 8'
'On-Wall'Solution'Only' ' ' ' ' ' ' ' ' ' ' ' ' ' ' 9' '
Optional'Condensate'Pump'Installation'' ' ' ' ' ' ' ' ' ' ' ' 11' '
Operating'Instructions....................................................................................................................'12'
Maintenance...................................................................................................................................' 13'
Wiring'Schematic.............................................................................................................................'13'
Troubleshooting...............................................................................................................................'14'
Warranty'Information......................................................................................................................' 15
Safety Notes
l The!IW-25-4!Dehumidifier'must'always'be'connected'using'a'grounded'electrical'connection'as'
required'for'all'electrical'appliances.'The'warranty'is'voided'and'all'responsibility'for'the'operation'is'
born'by'the'owner'if'non-grounded'wiring'is'utilized.'
l The'IW-25-4'Dehumidifier'must'only'be'installed,'maintained'and'serviced'by'a'qualified'technician.''
Follow'all'state'and'local'plumbing'and'electric'codes.'
l The!IW-25-4!Dehumidifier'is'intended'only'for'operation'when'the'unit'is'wall'mounted'or'in'wall'and'
level.'Any'other'orientation'could'cause'water'to'contact'electrical'components.' ' ' '
l If'any'water'may'have'spread'throughout'the'unit,'the'unit'should'be'opened'and'allowed'to'dry'
thoroughly'before'reconnecting'to'electric'and'restarting.'
l For'proper'operation,'no'obstruction'should'be'located'within'36”'of'the'discharge'of'the'unit' ' '
l Do'not'insert'any'objects'or'fingers'into'the'inlet'or'discharge.'If'service'is'required,'call'a'qualified'
technician.'All'work'on'unit'should'be'done'with'the'unit'“off”'and'unplugged'or'the'breaker'turned'
“off.”'
l Do'not'use'water'to'clean'the'unit'exterior.'Only'use'a'damp'cloth'to'clean'the'exterior'and'always'
unplug'or'disconnect'the'power'of'unit'first.'

3
l The'drain'hose'must'be'installed'to'ensure'the'proper'flow'of'condensate'water'to'a'drain'source.'
!
Identification:!
For'future'reference,'write'down'the'model,'serial'number,'date'of'purchase'so'you'can'identify'
your'unit'when'seeking'assistance'in'the'future.'The'data'label'on'the'side'of'your'unit'has'key'
characteristics'of'your'specific'unit.'
Model'Number' ' ' ' ' ' IW-25-4'
Serial'Number'_____________________________'
Date'of'Purchase' _____________________________'
'
For'additional'questions'concerning'the'operation'of'your'dehumidifier,'please:'
'
q Contact'your'installing'contractor' '
q Please'call'Innovative'Dehumidifier'systems,'LLC.'Support'Team'at'910-579-3348'
'
Electrical!Supply:'
Power'Supply:'120'V,'60'Hz'AC,'Single'Phase''
Outlet'Requirement:'3-Prong,'GFCI'
Circuit'Protector:'15'Amp'Time'Delay'Fuse'or'Circuit'Breaker'
WARNING:' ' 120'Volts'AC'may'cause'serious'injury'from'electric'shock.'
To'ensure'safety:'
1. Disconnect'electrical'power'before'servicing'
2. Only'plug'unit'into'grounded'electrical'circuit'
3. Do'not'use'extension'cord'
4. Do'not'use'plug'adapter'
!
Principle!of!Operation!
The'IW-25-4'Dehumidifier'utilizes'its'integral'humidistat'to'monitor'the'conditioned'space.'When'the'
relative'humidity'goes'above'the'selected'set'point,'the'dehumidifier'will'energize.'Air'is'drawn'across'an'
evaporator'coil,'which'is'cooler'than'the'dew'point'of'air.'This'means'moisture'will'condense'out'of'the'
air.'The'air'is'then'reheated'through'the'condenser'coil'and'distributed'back'into'the'room.' '
'

4
IW-25-4 Dehumidifier Diagram
Front!View!
+
Back View
Back!cover!
Air!Discharge!
!!!!Front!Cover!Screws'
'
!
Power!cord!routing!
options!
Chassis!
!
Front!cover!
Rear!top!cover'
Drain!line!routing!
options!
Filter!replacement!
reminder
Security!Screw!
Mounting!Holes!
(On-Wall!Solution)!
Keyhole!Mounting!Holes!
(On-Wall!Solution)!
Air!Intake!
In-Wall!Solution!
On-Wall!Solution!

5
Dimension Diagram
In-Wall'Solution'
!
On-Wall'Solution'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'

6
'
Dehumidifier Installation
Step!1.'Cut'the'two'zip'ties,'remove'the'three'screws'from'the'shipping'bracket,'then'remove'the'
shipping'bracket.'Fasten'mounting'tabs'(4)'with'screws'provided'to'the'chassis'(In-Wall!Only)'
'
'
CAUTION:!'
Location'of'Electric'Control'Box,'Water'Collect'Tray' '
Step!2.!Connect'power'to'unit'using'either'included'10’'power'cord'or'the'unit'can'be'hardwired.' '
WARNING!'
SHUT!OFF!BREAKER!/!POWER!/Make!sure!power!cord!is!unplugged!BEFORE!Wiring!Unit.!
There'are'two'reserved'power'cord'holes,'one'on'the'back'and'
one'on'the'bottom'of'the'unit.'Remove'appropriate'knock'out'as'
needed.'Complete'electrical'connections:'
•'White'to'White'(L)' ' '
•'Green'to'Green'(GRN)' ' '
•'Black'to'Black'(N)' ' '
Attach!mounting!
tabs!to!chassis!for!
in-wall!mounting!
only!
!

7
'
After'complete'electrical'connections,'slide'electrical'connection'inside'unit,'fasten'the'strain'
relief'to'the'power'cord'and'then'snap'it'on'the'selected'power'cord'holes.'All!state!and!local!
electrical!codes!must!be!adhered!to!for!proper!unit!operation!and!warranty!compliance.!
'
Step!3.!The'drain'hose'can'be'routed'through'the'back,'side,'or'bottom'of'the'unit.'Remove'the'
appropriate'knock-out'or'plug'for'your'application.' '
Pipe!Connection!(No!Pump):!
Step!4.!Slide'the'grommet'over'the'drain'hose'and'snap'into'place'at'the'selected'drain'location.'
Use'hex'nut'screwdriver'to'apply'hose'clamp'to'the'drain'hose.'

8
IN-WALL!ONLY!–!SEE!PAGE!9!for!Balance!of!ON-WALL!Installation!Instructions! !
!
NOTE:!If'mounting'unit'to'drywall,'position'mounting'template'so'that'1'of'the'keyhole'mounting'
locations'is'on'a'stud.!
Step!5.'Select'mounting'location'between'two'studs.'
Step!6.'Using'the'mounting'template'on'the'front'cover'box,'mark'install'location'on'wall.'
Step!7.!Cut'hole.'(Rough'Opening'Dimensions:'28.0”'x'14.5”'5.75”)'
Step!8.'Lift'the'unit'and'place'it'near'the'wall'opening'to'route'electrical'wires'and'drain'hose'
through'appropriate'knockouts.'
Step!9.!Once'electrical'and'drain'hose'are'routed'through'the'unit,'set'the'unit'into'the'wall.'
'
'
'
'
'
'
Step!10.!The'chassis'of'the'units'slips'in'the'wall'from'the'front'and'is'secured'by'the'four'
mounting'tabs'with'screws'(not'provided).' ' Ensure!the!unit!is!level!and!the!bottom!of!the!unit!
is!supported!before!screwing!through!the!drywall!and!into!the!studs.!
Step!11.!Connect'the'drain'line'to'the'drain'source'making'sure'to'have'adequate'slope'on'the'
drain'hose.'
Step!12.!Turn'breaker/power'back'on.'
Step!13.'Set'the'digital'controller'to'desired'RH.'See'Operating'Instructions'(Page'12)'
Step!14.'Install'diffuser'cover'by'aligning'the'lower'tabs'first,'then'setting'the'cover'back'against'
the'wall.'Insert'the'included'four'tamper-resistant'screws'to'secure'the'diffuser'cover.'
'
!
!
!
!
!
!

9
!
!
!
ON-WALL!ONLY!(SEE!PAGE!8!for!IN-WALL!Specific!Instructions)!
!
Step!5:'Install'2'screws'on'the'wall'(Select'appropriate'hardware'based'on'
application).'Leave'screw'head'3/16”'out'from'the'wall'surface'to'allow'the'unit'to'
be'slipped'over'the'screws'into'the'teardrop'shaped'hanger'holes'on'the'rear'of'
the'dehumidifier.' '
'
Step!6:!Hanging'the'unit'on'the'wall'
Position'keyhole'mounting'slots'over'screws'in'wall.'Allow'unit'to'drop'onto'screws.'

10
!
!
!
!
Step!7:'Secure'the'unit'with'the'2'safety'mounting'screws.'
'
Step!8.!Turn'breaker/power'back'on.'
Step!9.'Set'the'digital'controller'to'desired'RH.'See'Operating'Instructions'(Page'12)'
Step!10.'Install'diffuser'cover'by'aligning'the'lower'tabs'first,'then'setting'the'cover'back'against'
the'wall.'Insert'the'included'four'tamper-resistant'screws'(2'tamper-resistant'screws'on'the'left'
and'right'sides'and'2'tamper-resistant'screws'on'the'bottom)'to'secure'the'diffuser'cover.'
'
!
!
!
!
Altri manuali per IW-25-4
1
Indice
Altri manuali Innovative Dehumidifier Deumidificatore