4 pH Public
2. INSTALLATION
2.1. Mechanical and hydraulic installation
During installation ensure that the mains cable is disconnected from
the power supply.
Acids are very corrosive and can harm you eyes, skin and airways.
When working with pH correctors necessary caution and preventive
measures should be taken. Always wear safety googles, gloves and
clothing.
Acid container. We strongly recommend to place the acid container outside the
filter shed. If it is not possible, ensure the adequate ventilation is provided and
place the container as far from metallic and electronic equipment as possible and
NEVER underneath the pump or other device.
Control device. Install the device on the wall in an easy to access location using
the bracket provided. Before attaching the bracket to the pump, use the bracket to
mark in the wall the location of the holes you will need to make for the screws.
Wireless pump. Install the pump on the wall in an easy to access location using
the bracket provided. Before attaching the bracket to the pump, use the bracket to
mark in the wall the location of the holes you will need to make for the screws.
Choose a location close to the injection point.
Injection. Install the clamp saddle provided in the return pipe after all other
equipment (pump, filter, heater, chlorinator etc.). It should be the last element on
the return line. Install the injection one way valve on the clamp saddle. Use Teflon
tape to seal the thread. Connect the injection rigid tubbing to the valve.
Connect the other end of the injection tube to the injection connection (upper side)
of the pump.
Suction. Connect the suction tube to the suction connection (down side) of the
pump. Use a length of tube long enough to reach from the acid container to the
pump (max. 1,5 meters).
Probe. Install pH probe preferably after the filter. If there is a salt water
chlorinator, the probe must be installed before the cell and as far as possible from
it. Try to choose a point in the circuit that never gets empty of water, because the
probe deteriorates very quickly when dry.
2.2. Electrical installation
Power supply
Connect the 230 VAC power supply cable plug (3) into a mains power point
provided with a protective earthing conductor (PE)