Connector Wiring
Start Switch (Pin 9)
This input is from a momentary contact closure that supplies +12 volts to start
the flash sequence.
FRAA - Flash Red ONLY After Amber (Pin 10)
This grounded input from the door switch will cause the red lights to flash after the start switch
is activated and the amber lights are flashing.
FR - Flash Red When Door is Opened (Pin 11)
This grounded input from the door switch will cause the red lights to flash anytime the door is
opened (non-sequential operation).
Stop Arm (Pin 3)
This output supplies +12 volt power to actuate the stop arm device(s) when the red lights
operate. If the load is more than 3 amps a relay circuit should be used (see Wiring Diagrams).
Four lamp applications require different wiring (see Figure 3).
Ground (Pin 12)
Logic and power ground for the flasher/controller unit. This must be a good quality ground
connection.
Left Amber Lights (Pin 1)
This output provides the +12 volt power to flash the left front and left rear
Amber lights at a rate of 75 flashes per minute at a 50% duty cycle.
Override Switch (Pin 8)
An override switch may be used to function as a backup device as well as a means to
immediately start the red lights flashing, bypassing the door switch and start button. The +12
volt power must be adequately fused. The override switch requires two contacts, one for Pin 8
and the second for Pin 11.
Right Amber Lights (Pin 5)
This output provides the +12 volt power to flash the right front and right rear amber lights at a
rate of 75 flashes per minute at a 50% duty cycle.
Left Red Lights (Pin 2)
This output provides the +12 volt power to flash the left front and left rear red lights at a rate of
75 flashes per minute at a 50% duty cycle.
Master Switch (Pin 6, 7)
This is the input for the 12 volt power, and must be adequately fused.
Right Red Lights (Pin 4)
This output provides the +12 volt power to flash the right front and right rear red lights at a rate
of 75 flashes per minute at a 50% duty cycle.
InPOWER LLC
3555 Africa Road
Galena, Ohio 43021
Tel 740-548-0965 Fax 740-548-2302
www.InPowerDirect.com
InPower wants to ensure total customer
satisfaction. Please download a product
evaluation form at www.InPowerDirect.com/
customer_evaluation.htm or call us toll free
at 866-548-0965 to be sent a form by mail.
Warranty
InPOWER LLC warrants its products to be free from defects in material and workmanship
under normal use, care and maintenance for a period of two (2) years from the date of
shipment. Please see www.inpowerdirect.com/warranty.htm for specifics or call 866-548-0965
for a copy of our warranty policy.