Optional “Timed” Dispense:
This function is appropriate when the cup/teapot
being lled is always the same size/capacity.
To change boiler from “on-demand” default
setting to “Timed” dispense:
• Switch o on front of unit.
• Unplug from mains power supply and
wait 10 seconds.
• Plug boiler back in and at the same time,
press & hold the dispense button for
5 seconds.
• Boiler will either start to ll with water or
the dispense button will begin to ash
(depending on water level in tank).
• Place vessel on drip-tray.
• Press & hold the dispense button to ll
vessel to the required level. Release button
to stop dispense (NOTE: This can be
repeated as many times as necessary,
to get the level correct).
• Once level in vessel is correct, press
the ON/OFF button (below display) to
save the measured dispense amount
(this saves the setting and puts the
boiler into standby mode).
• To continue, switch boiler back on by
pressing the ON/OFF button again.
• The boiler will now dispense the measured
amount into the cup/teapot, each time the
button is pressed.
Top-up Feature:
• At the end of the timed dispense cycle,
the “CAUTION” message will continue to
ash for a further 5 seconds. During this
5-second window, the water level in the
cup or teapot can be topped-up by simply
pressing & holding the dispense button.
NOTE: Once the “CAUTION” message stops
ashing, the top-up facility ends and the
boiler reverts back to timed dispense mode.
Regular Daily Use
Switch boiler on and wait for the screen to
turn white and show “READY” message and
dispense button to turn red. The water will
then be at the correct temperature. (the unit
will not dispense until the water has reached
temperature and button is illuminated).
Dispense water by pressing illuminated
push-button.
Filter Counter (optional if a filter
or softener has been fitted):
If an external lter/softener is tted to the unit
there is an optional lter-counter installed in
the software. This counter measures the water
passing through the boiler and reminds the
customer (via the display screen) to change the
lter when required. Note: This counter is set
to ‘Off’ as standard.
To enable lter-counter, proceed as follows:
• Turn machine o on front panel.
• Press & hold “on/o” button
(for approximately 12 seconds) until red
screen shows “PR” in centre of screen,
then release button. Temperature setting
is displayed.
• Press & hold button (long push) for
approximately 5 seconds until screen
changes to show “empty lter symbol”
(default lter setting).
• Press button (short push) to scroll between
the dierent lter settings;
SOFT (13001 litres)
MEDIUM (9001 litres)
HARD (6001 litres)
EMPTY FILTER SYMBOL (No Filter counter).
• With the required lter setting selected,
Press & hold button (long push) for 4 seconds
to save.
• Press & hold button (long push) for
approximately 6 seconds until display
goes blank.
• Turn machine back on again.
5