insys icom i-modul 336 LL Manuale utente

INSYS Modem 336 LL
4D/2D AC/DC
Manual


Copyright © March 14 INSYS MICROELECTRONICS GmbH
Any duplication of this manual is prohibited. All rights on this documentation and
the devices are with INSYS MICROELECTRONICS GmbH Regensburg.
Trademarks
The use of a trademark not shown below is not an indication that it is freely availa-
ble for use.
MNP is a registered trademark of Microcom Inc.
IBM PC, AT, XT are registered trademarks of International Business Machine Cor-
poration.
INSYS®, e-Mobility LSG® and e-Mobility PLC® are registered trademarks of INSYS
MICROELECTRONICS GmbH.
Windows™ is a registered trademark of Microsoft Corporation.
Linux is a registered trademark of Linus Torvalds.
Publisher:
INSYS MICROELECTRONICS GmbH
Hermann-Köhl-Str. 22
D-93049 Regensburg, Germany
Phone: +49 941 58692 0
Fax: +49 941 58692 45
Internet: http://www.insys-icom.com
Date: Mar-14
Item: 31-22-03.131
Version: 1.0
Language: DE

Content
4Mar-14
1Safety.......................................................................................................6
2Scope of Delivery.....................................................................................8
3Usage According to the Regulations........................................................9
4Technical Data .......................................................................................10
4.1 Physical Features.................................................................................................10
4.2 Technological Features ........................................................................................11
4.3 Certifications........................................................................................................11
5Display and Control Elements ................................................................12
5.1 Meaning of the Displays ......................................................................................13
5.2 Function of the Control Elements ........................................................................13
6Connections...........................................................................................14
6.1 Front Panel Connections......................................................................................14
6.2 Terminal Connections on the Top ........................................................................15
6.3 Terminal Connections on the Bottom ..................................................................16
6.4 Pin Assignment of the Serial Interface.................................................................17
6.5 Pin Assignment RJ45-Socket ..............................................................................17
7Function Overview .................................................................................18
8Meaning of the Symbols and the Formatting in this Manual..................20
9Installation .............................................................................................21
10 Initial Operation......................................................................................25
11 Operating Principle ................................................................................30
11.1 Operation with the Terminal Program..................................................................30
12 Functions ...............................................................................................32
12.1 Automatic Baud Rate Detection ..........................................................................32
12.1.1 Serial Connection ................................................................................... 32
12.1.2 Phone connection .................................................................................. 33
12.2 Bit Direct Mode ...................................................................................................33
12.3 Data Flow Control (Handshake) ...........................................................................34
12.3.1 Hardware data flow control (RTS/CTS) .................................................. 34
12.3.2 Software data flow control (XON/XOFF) ................................................ 34
12.4 Data Compression ...............................................................................................35
12.5 Data Buffer for Serial Data Transmission .............................................................36
12.6 Error correction....................................................................................................37
12.7 IO Tunneling and Connection Safeguard .............................................................38
12.8 Set Two-Wire or Four-Wire Operation .................................................................39
12.9 Adjusting the Transmission Level ........................................................................39
12.10 Set the Operating Modes Answer or Originate ....................................................40

Contents
Mar-14 5
12.11 Digital inputs .......................................................................................................41
12.12 Switch Outputs....................................................................................................41
12.13 Switching on the Remote Configuration..............................................................42
12.14 Remote Configuration of the INSYS Modem 336 LL 4D/2D AC/DC.....................43
12.15 Reset of the Device..............................................................................................44
13 Maintenance ..........................................................................................45
14 Diagnosis and Testing of the Path..........................................................47
14.1 Line Optimization.................................................................................................47
14.2 Error Sources.......................................................................................................47
15 Waste Disposal ......................................................................................48
15.1 Repurchasing of Legacy Systems........................................................................48
16 Declaration of Conformity ......................................................................49
17 AT Command Reference ........................................................................50
17.1 AT Messages .......................................................................................................66
18 S Registers.............................................................................................69
18.1 Overview S Registers...........................................................................................69
18.2 Description S Registers .......................................................................................70
19 Tables and Diagrams..............................................................................79
19.1 List of Tables .......................................................................................................79
19.2 List of Diagrams ..................................................................................................79
20 Index......................................................................................................80

Safety
INSYS Modem 336 LL
6
1Safety
Danger!
Extremely dangerous operating voltage!
Risk of death through electric shock hazard!
Prior to any technical or mechanical work at the INSYS
Modem 336 LL 4D/2D AC/DC, switch the power off and
secure the INSYS Modem 336 LL 4D/2D AC/DC against
being switched on again.
Danger!
Moisture und liquids from the environment may seep
into the interior of the device.
Risk of death through shock hazard on touch!
The INSYS Modem 336 LL 4D/2D AC/DC may not be used
in wet or damp environments, or in or very close to wa-
ter. Install the device at a dry location, protected from
water spray. Switch the power supply off before you do
any work on a device which may have been in contact
with moisture.
Danger!
Overvoltage.
Fire hazard!
The INSYS Modem 336 LL 4D/2D AC/DC must be secured
with a suitable fuse against overvoltage. A INSYS Modem
336 LL 4D/2D AC/DC with UL certification must be pro-
tected by a UL-certified fuse.
Gefahr!
Over-current.
Fire hazard!
The product must be protected against currents exceed-
ing 1.6 A with a suitable fuse. Use an overcurrent protec-
tion device with high interrupting rating (1500 A).

INSYS Modem 336 LL
Safety
7
Warning!
Short circuits and damage due to improper repairs and
opening of maintenance areas.
Fire, breakdown and risk of injury!
Only trained personnel are allowed to open the INSYS
Modem 336 LL 4D/2D AC/DC and to repair it.
Note
Damage of the device due to overvoltage!
Voltage peaks from the power supply may damage the
device.
Install suitable overvoltage protection.
Note
Damage due to chemicals!
Ketones and chlorinated hydrocarbons dissolve the plas-
tic housing and damage the surface of the device.
Never let the device come into contact with ketones (e.g.
acetone) or chlorinated hydrocarbons, such as dichloro-
methane.

Scope of Delivery
INSYS Modem 336 LL
8
2Scope of Delivery
The scope of delivery for the INSYS Modem 336 LL 4D/2D AC/DC includes all accessories
listed below. Please check if all accessories are included in the box. If a part is missing or
damaged, please contact your distributor.
INSYS Modem 336 LL 4D/2D AC/DC
Cable:
1 serial cable with 9-pn Sub-D plug for the connection to the PC
1 manual

INSYS Modem 336 LL
Usage According to the Regulations
9
3Usage According to the Regulations
The INSYS Modem 336 LL 4D/2D AC/DC may only be used for the purposes specified in
the function overview. In addition, it may be used for the following purposes:
Usage and mounting in an industrial cabinet.
Switching and data transmission functions in machines according to the
machine directive 2006/42/EC.
Usage as data transmission device for a PLC.
The INSYS Modem 336 LL 4D/2D AC/DC must not be used for the following purposes and
used or operated under the following conditions:
Controlling or switching of machines and systems which do not comply
with the directive 2006/42/EC.
Usage, controlling, switching and data transmission in machines or
systems which are operated in explosive atmospheres.
Controlling, switching and data transmission of machines, which may
involve risks to life and limb due to their functions or when a breakdown
occurs.

Technical Data
INSYS Modem 336 LL
10
4Technical Data
4.1 Physical Features
Danger!
Extremely dangerous operating voltage!
Risk of death through electric shock hazard!
Prior to any technical or mechanical work at the INSYS
Modem 336 LL 4D/2D AC/DC, switch the power off and
secure the INSYS Modem 336 LL 4D/2D AC/DC against
being switched on again.
Danger!
Overvoltage.
Fire hazard!
The modem must be secured with a suitable fuse against
overvoltage.
An easily accessible isolation device that disconnects all lines must be installed prior to
commissioning of the device to be able to isolate it completely from power supply.
All specified data was measured with a nominal input voltage, at full load, and an ambi-
ent temperature of 25 °C. The threshold value tolerances are subject to typical fluctua-
tions.
Altri manuali per i-modul 336 LL
2
Indice
Altri manuali insys icom Modem

insys icom
insys icom Pocket ISDN Manuale utente

insys icom
insys icom i-modul 336 LL Manuale utente

insys icom
insys icom GPRS 5.1 Manuale utente

insys icom
insys icom i-modul 144/56k Manuale utente

insys icom
insys icom MRX Manuale utente

insys icom
insys icom GSM 4.3 compact Manuale utente

insys icom
insys icom MIRO Manuale utente

insys icom
insys icom 56k Manuale utente

insys icom
insys icom i-modul 336 LL Manuale utente

insys icom
insys icom ADSL 1.0 Series Manuale utente