INSYS 56k Small INT 2.0 Istruzioni per il montaggio

Manual
INSYS Modem 56k
Small INT 2.0
Nov-07


Copyright © November 07 INSYS MICROELECTRONICS GmbH
Any duplication of this manual is prohibited. All rights on this documentation and the
devices are with INSYS MICROELECTRONICS GmbH Regensburg.
Restrictions of guarantee
This handbook contains a concise description. The compilation of the text has been made
with the utmost care. Despite all efforts, there may be deviations compared with the ac-
tual functions. No guarantee can therefore be given for the accuracy of the contents. We
can neither take over a legal responsibility nor any liability for incorrect information and
their consequences. Suggestions for improvements and comments are gladly accepted.
Trademarks
The use of a trademark not shown below is not an indication that it is freely available for
use.
MNP is a registered trademark of Microcom Inc.
IBM PC, AT, XT are registered trademarks of International Business Machine Corporation.
INSYS ® is a registered trademark of INSYS MICROELECTRONICS GmbH.
Windows™ is a registered trademark of Microsoft Corporation.
Publisher:
INSYS MICROELECTRONICS GmbH
Waffnergasse 8
D-93047 Regensburg, Germany
Phone: +49 (0)941/56 00 61
Fax: +49 (0)941/56 34 71
Internet: http://www.insys-tec.de
Subject to technical changes as well as correction.
Date: Nov-07
Item: 31-22-03.051
Version: 2.0
Language: EN

Contents
4Nov-07
1Safety .................................................................................................................. 6
2Scope of Delivery ................................................................................................ 8
3Usage According to the Regulations .................................................................. 9
4Technical Data................................................................................................... 10
4.1 Physical Features ..............................................................................................................10
4.2 Technological Features.....................................................................................................10
5Display and Control Elements........................................................................... 11
5.1 Meaning of the Displays...................................................................................................11
6Connections....................................................................................................... 12
6.1 Front Panel Connections...................................................................................................12
6.2 Terminal Connections on the Top ....................................................................................12
6.3 Pin Assignment of the Serial Interface.............................................................................13
6.4 RJ12 Phone connection.....................................................................................................14
7Function Overview............................................................................................ 15
8Meaning of the Symbols and the Formatting in this Manual.......................... 17
9Mounting .......................................................................................................... 18
10 Initial Operation................................................................................................ 22
11 Operating Principle........................................................................................... 24
11.1 Operation with the Terminal Program.............................................................................24
11.2 Operation with HSComm Modem....................................................................................25
11.3 User Interface of the Software HSComm Modem ...........................................................26
12 Functions........................................................................................................... 29
12.1 Select country-spezific presets.........................................................................................29
12.2 Automatic Baud Rate Detection.......................................................................................30
12.2.1 Serial Connection ............................................................................................................ 30
12.2.2 Phone connection ........................................................................................................... 31
12.3 Data Buffer for Serial Data Transmission.........................................................................31
12.4 Bit Direct Mode .................................................................................................................32
12.5 Data Flow Control (Handshake) .......................................................................................32
12.5.1 Hardware data flow control (RTS/CTS)...................................................................... 32
12.5.2 Software data flow control (XON/XOFF) .................................................................. 33
12.6 Error correction .................................................................................................................34
12.7 Data Compression.............................................................................................................34
12.8 Selective Call Acceptance .................................................................................................35
12.9 Sending messages via data connection, SMS or Fax .......................................................37
12.10 Manual Sending of Messages...........................................................................................39
12.11 Switching on the Remote Configuration .........................................................................39
12.12 Remote Configuration of the INSYS Modem 56k Small INT 2.0......................................40
12.13 Access Control and Security Callback...............................................................................41

Contents
Nov-07 5
12.14 Idle Connection Control with Data Transmit Control......................................................43
12.15 Priority Circuit for a Phone Connected in Series to the INSYS Modem 56k Small INT 2.0..
...........................................................................................................................44
12.16 Reset ...........................................................................................................................46
13 Maintenance ..................................................................................................... 48
14 Waste Disposal.................................................................................................. 50
14.1 Repurchasing of legacy systems.......................................................................................50
15 AT Command Reference ................................................................................... 51
15.1 AT Messages......................................................................................................................76
16 Country Codes................................................................................................... 79
17 S Registry........................................................................................................... 83
17.1 Overview S Registry..........................................................................................................83
17.2 Description S Registry.......................................................................................................85
18 SMS Provider / Service Center: ......................................................................... 94
18.1 SMS as Fax.........................................................................................................................94
18.2 SMS as E-Mail....................................................................................................................94
19 Tables and Diagrams......................................................................................... 95
19.1 List of Tables .....................................................................................................................95
19.2 List of Diagrams ................................................................................................................95

Safety INSYS Modem 56k Small INT 2.0
6
1Safety
Danger!
Moisture und liquids from the environment may seep
into the interior of the device.
Risk of death through shock hazard when touching it!
The INSYS Modem 56k Small INT 2.0 may not be used in
wet or damp environments, or in or very close to water.
Install the device at a dry location, protected from water
spray. Switch the power supply off before you do any
work on a device which may have been in contact with
moisture.
Danger!
Overvoltage.
Fire hazard!
The modem must be secured with a suitable fuse against
overvoltage.
Warning!
Short circuits and damage due to improper repairs and
opening of maintenance areas.
Fire, breakdown and risk of injury!
Only trained personnel are allowed to open the INSYS
Modem 56k Small INT 2.0 and to repair it.
Note
Damage of the device due to overvoltage!
Voltage peaks from the power supply may damage the
device.
Install suitable overvoltage protection.

INSYS Modem 56k Small INT 2.0 Safety
7
Note
Damage due to chemicals!
Ketones and chlorinated hydrocarbons dissolve the plas-
tic housing and damage the surface of the device.
Never let the device come into contact with ketones (e.g.
acetone) or chlorinated hydrocarbons, such as dichloro-
methane.

Scope of Delivery INSYS Modem 56k Small INT 2.0
8
2Scope of Delivery
The scope of delivery for the INSYS Modem 56k Small INT 2.0 includes all accessories
listed below. Please check if all accessories are included in the box. If a part is missing or
damaged, please contact your distributor.
¾INSYS Modem 56k Small INT 2.0
¾Cable:
•1 phone cord (TAE-N to RJ12)
•1 serial cable with 9-pin sub-D plug for the connection to the PC
¾1 manual

INSYS Modem 56k Small INT 2.0 Usage According to the Regulations
9
3Usage According to the Regulations
The INSYS Modem 56k Small INT 2.0 may only be used for the purposes specified in the
function overview. In addition, it may be used for the following purposes:
•Usage and mounting in an industrial cabinet.
•Switching and data transmission functions in machines according to the
machine directive 2006/42/EG.
•Usage as data transmission device for a PLC.
The INSYS Modem 56k Small INT 2.0 may not be used for the following purposes and
used or operated under the following conditions:
•Controlling or switching of machines and systems which do not comply
with the directive 2006/42/EG.
•Usage, controlling, switching and data transmission in machines or sys-
tems which are operated in explosive atmospheres.
•Controlling, switching and data transmission of machines, which may in-
volve risks to life and limb due to their functions or when a breakdown oc-
curs.

Technical Data INSYS Modem 56k Small INT 2.0
10
4Technical Data
4.1 Physical Features
Danger!
Overvoltage.
Fire hazard!
The modem must be secured with a suitable fuse against
overvoltage.
All specified data was measured with a nominal input voltage, at full load, and an ambi-
ent temperature of 25 °C. The threshold value tolerances are subject to typical fluctua-
tions.
Physical Feature Value
Operating voltage 10..32 V DC voltage
Power input sleep 2.4 W
Power input connection 2.6 W
Weight 100 g
Dimensions (Width x Depth x Height) 23 mm x 110 mm x 75 mm
Temperature range 0 °C – 55 °C
Maximum allowed humidity 95 % non-condensing
Table 1: Physical Features
4.2 Technological Features
Technological Feature Description
Protection Class Housing IP40
Terminals IP20
Supported data compression standards MNP 2/3, MNP 5, V.42 bis; V.44, MNP 10,
MNP 10 EC
Fax-Classes Fax Class 1/2
Modulation types V.32bis, V.32, V.23, V.22, V22 bis, V21,
V.34+, V.34, V.42, (bei 56k-Version zusätz-
lich V.90 und V.92)Bell Norm 103/212
Error correction standards MNP4, LAPM
Tabelle 1: Technological Features
Altri manuali per 56k Small INT 2.0
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali INSYS Modem

INSYS
INSYS GSM 4.3 easy Manuale utente

INSYS
INSYS 56k Small INT 2.0 Manuale utente

INSYS
INSYS MoRoS Manuale utente

INSYS
INSYS i-modul 336 LL Manuale utente

INSYS
INSYS GSM 4.3 I4 Manuale utente

INSYS
INSYS 56k small EU 2.1 Manuale utente

INSYS
INSYS ADSL 1.1 Manuale utente

INSYS
INSYS Modem 336 LL 2D/4D 5.x Originate / Answer Manuale utente

INSYS
INSYS 336 4.1 Manuale utente

INSYS
INSYS MoRoS Manuale utente



















