Intec Force 1 Manuale utente

Instruction Manual
3771 Monarch Street • Frederick, CO 80530 • www.inteccorp.com
Local: (303) 833-6644 • Fax: (303) 833-6650 • Toll Free: (800) 666-1611

THE FORCE
/
1
Table of Contents
CONTENTS
Machine Information ......................................................................2
Contacting Intec ..............................................................................3
Introduction ....................................................................................4
Overview ........................................................................................5
How The System Works Together ..............................................10
Safety First ....................................................................................11
Set-Up & Operation ......................................................................12
Operational Guidelines ................................................................16
Sidewalls & Insulation Material....................................................18
Generators and Extension Cords ................................................20
Maintenance ..................................................................................21
Troubleshooting ............................................................................29
Mechanical Drawings....................................................................33
Electrical Drawings........................................................................39
Claims, Damage or Loss ..............................................................44
Returns ..........................................................................................46
Replacement Parts ........................................................................47
Warranty ........................................................................................48
Insulation Terms And Values ......................................................49
1

MACHINE INFORMATION
2

Rev 05/10
Phone support:
Available Monday - Friday, excluding holidays. In the United States and
Canada, call (800) 666-1611, 7:00 A.M. to 5:00 P.M. Mountain Time. Ask for
technical support and one of our technicians will be glad to help you.
On-site/o-site repair support:
Available Monday to Friday, excluding holidays. In the United States and
Canada, call (800) 666-1611, 7:00 A.M. to 5:00 P.M. Mountain time. For the
latest repair/service centers across the United States visit our web site,
www.inteccorp.com and go to service centers. All service centers are
independently owned and operated and are not part of Intec. Consult the
nearest service center for the hours of operation and lead time for repair.
Website support:
Visit our web site 24/7 at www.inteccorp.com and go to the specific
model your wanting information on, then go to the technical bulletins
section. The technical section of the web site is constantly being updated
with new information and technical documents. If you cannot find what
you are looking for please contact us Monday - Friday, excluding holidays,
in the United States and Canada, call (800) 666-1611, 7:00 A.M. to 5:00 P.M.
Mountain Time. Ask for technical support and one of our technicians will
be glad to help you.
Contact Information:
3771 Monarch Street
Frederick, CO 80530
Ph: 1-303-833-6644
1-800-666-1611
Fax: 1-303-833-6650
E-mail: [email protected]
3
THE FORCE
/
1
Contacting Intec

THE FORCE
/
1
Insulation Blowing Machine
INTRODUCTION
4
Your FORCE/1 insulation blowing machine, the product of years of
laboratory and field testing, offers both the contractor and the
homeowner exceptional performance, total reliability, and ease of use.
It is designed and built to blow-in more than 500 pounds of material
per hour. No other machine in its class can match the performance of
the FORCE/1.
Because no insulation actually goes
through the blower, the FORCE/1 is a
virtual workhorse, requiring only minimal
maintenance and almost no
downtime. The direct drive
feature also means there are no
chains for you to adjust or
replace, ever.
By following the instructions in
this manual, setting up and
operating the FORCE/1 on your
jobsite will be uncomplicated, quick, safe, and easy. Once your work
is finished, end-of-the-day clean up is equally efficient.
Exceptional performance. Total reliability. Ease of use. Those are the
reasons why the FORCE/1 was your best choice.
Rex Deitesfield
President

5
THE FORCE
/
1
Overview
Height 41''
Width 32 - 1⁄4"
Weight 177 lbs.
Hopper Capacity 25 lbs.
Hose Size 2- 1⁄2"
Blower 104 CFM, 2.5 PSI (AVG) 8 amps
Agitator Motor 3⁄4hp - 9.5 amps, 115 VAC
Gearbox Custom, direct drive
Airlock 6- 1⁄2" x 7-1⁄4" opening, steel, 6-vane,
cast urethane seals
Electric 115V/20 amp 50/60Hz
220V/10 amp 50/60Hz (optional)
Agitator 3-vane
Wheels 6"
Warranty One year limited;
90 days limited on electric,
blower and airlock system
Specications are subject to change without notice.

OVERVIEW
6
THE FORCE
/
1
Overview
Three subsystems make up your FORCE/1:
THE AGITATOR AND AIRLOCK.
Your FORCE/1 runs on a 3⁄4
horsepower motor driving an enclosed gearbox. The airlock positions
the material for proper distribution by the blower.
THE BLOWER MOTOR.
Your FORCE/1 is equipped with a
104 CFM two-stage blower motor to push the material through the hose
and into the attic with optimum pressure and output. The blower is
connected to the air intake port of the airlock by a metal sleeve.
ELECTRICAL COMPONENTS.
Your FORCE/1 requires a
dedicated 20 amp grounded power supply. Less amperage will likely
trip circuit breakers. Always disconnect
the power source before beginning any
maintenance. And as with all electrical
systems, never attempt to operate your
FORCE/1 with either the operator or the
machine standing in water.
THE PARTS
(see next page for drawings)
A. Hopper: upper component of the FORCE/1 where insulation
is loaded.
B. Base: lower component of the FORCE/1 houses power
components, blower and airlock.
C. Slide gate: increases or decreases the amount of material
entering the airlock.
D. Electrical: on/off function of both the blower and agitator
motors.

THE FORCE
/
1
Overview
OVERVIEW
7
OVERVIEW
Example only see page 43 for specific electrical systems.

8
THE FORCE
/
1
Overview
OVERVIEW

9
Remote Switch
THE FORCE
/
1
Overview
OVERVIEW
Remote Cord
Power Cord
Agitator Switch
Blower Switch
Agitator