i200, i250, i200P, i250P General Information 4
1. General Information
1.1 Items Shipped With Water Heater
The following items are shipped with the water heater; upper
mounting bracket (1), condensate drain (2), communication
cable (3), Operation and Installation manual (4).
Note: Items 5 through 7 are spare parts shipped with the
unit. Two buss fuses, 10 Amp (5), electrode seal (6),
and O-rings (7).
IQ-103
To avoid productdamage,personal injury,or
evenpossibledeath,carefullyread,understand,
andfollowalltheinstructionsin theInstallation
andOperationmanuals before installingthis
product.Improperinstallation,adjustment,alteration,or
maintenance cancauseinjury,lossoflife,and/orproperty
damage. This water heater shouldbeinstalledand
servicedbyaqualied technician.Thelackofproper
servicecanresult in adangerouscondition.
Thismanualcontainssafetyinformation,installation
instructions, andmaintenanceprocedures.Itmustbeleft
withthehomeowneror placednear thewaterheaterin
a noncombustibleplace.Thecustomer shouldretainthis
manual forfuture reference.
WARNING
Ifthe informationintheseinstructionsisnot followed
exactly,afireorexplosioncouldresultcausing
propertydamage,personalinjury,ordeath.
—Donotstoreorusegasolineor otherflammable
vaporsandliquidsinthevicinity ofthisorany
otherappliance.
WHATTODOIFYOUSMELLGAS
•
Donottrytolight anyappliance.
•
Donottouchanyelectricalswitch;donot use
anyphoneinyourbuilding.
•
Immediatelycallyour gassupplierfroma
neighbor’sphone. Follow the gassupplier’s
instructions.
•
Ifyoucannotreachyourgassupplier,callthe
firedepartment.
—Installationandservicemustbeperformedby
aqualifiedinstaller,serviceagency,orthegas
supplier.
FACTORYPRESETFORUSEWITH
NATURALGAS
Direct-VentAutomaticInstantaneousWaterHeater
(Chauffe-eauautomatiqueinstantanéàventilationdirecte)
FORINDOORINSTALLATIONONLY
(POURINSTALLATIONÀL'INTÉRIEURSEULEMENT)
120Volt,60Hz,5Amps
TypeofGas
(Typedegaz)
:
................
InputRating
(EntrerleClassement)
:Btu/hrMaximum...
Btu/hrMinimum...
MaximumInletGasPressure:............
MinimumInletGasPressure:............
MinimumInletGasPressure(foradjustments):..
MaximumWaterPressure:.............
MinimumWaterPressure:.............
RecoveryRating:..................
..................
ThermalEffi
ciency/:
EnergyFactor:
NOxEmissions:
........
(PursuanttoSouthCoastAirQualityManagementDistrictRule1146.2)
(Moinsde20ppm)
(Jusqu'à98%/0.94)(Jusqu'à98%/0.94)
(Moinsde20ppm)
(Dégagementsminimums)
(Desnon-combustibles) (D'uneconstruction
combustible)
(conformémentaurèglement1146.2du"SouthCoastAirQualityManagementDistrict)
Topofheater
MinimumClearances
From
Non-Combustibles
FromCombustible
Construction
(Dessusduchauffe-eau)
Backofheater
(Arrièreduchauffe-eau)
Frontofheater
(Avantduchauffe-eau)
Bottomofcabinet
(Côtécanalisation)
Side(Côté)
5/8in(15.8mm)
6in(15.2cm)
6in(15.2cm)
2in(50.8mm)
12in(30.4cm)
5/8in(15.8mm)
6in(15.2cm)
2in(50.8mm)
1/2in(12.7mm)
12in(30.4cm)
IntellihotGreenTechnologiesInc.
2900W.MainSt.
Galesburg,IL61401
Phone:(877)835-1705
Email:info@intellihot.com
Web:www.intellihot.com
FactoryPreset
NaturalGas
(Réglageenusinepourgaznaturel)
199,000
20,000
13.0W.C.(3.20kPa)
8.0W.C.(2.00kPa)
8.0W.C.(2.00kPa)
150psi(1034kPa)
15psi(103kPa)
265GPH(1003LPH)
Upto98%/0.94
Lessthan20ppm
FieldConversion*to
PropaneGas
(Conversion*surplaceaugazpropane)
199,000
20,000
10.5W.C.(2.62kPa)
3.0W.C.(0.76kPa)
11.0W.C.(2.74kPa)
150psi(1034kPa)
15psi(103kPa)
265GPH(1003LPH)
Upto98%/0.94
Lessthan20ppm
CheckBoxif
Convertedto
PropaneGas
*RefertoInstallationandOperation
manualforconversionprocedure.
(Seréféreraumanueld'installationet
defonctionnementpourlaprocédurede
conversion.)
PRÉRÉGLAGESD'USINEPOURUTILISATIONAVEC
GAZNATUREL
(Pressiondegazd'arrivéemaximum)
(Pressiond'eaumaximum)
(Pressiond'eauminimum)
(Caractéristiquederecouvrement)
(Efficacitéthermique/Facteurénergétique)
(ÉmissionsdeNOx)
(Pressiondegazd'arrivéeminimum)
(Pressiondegazd'arrivéeminimum(pourajustements))
Cocherlacasesiconvertiaugazpropane
ETLSTICKER
SerialNumber:
IGT-LBL-0005-01
(Numérodesérie)
(CollantETL)
Operation and
Installation
Manual
Model: i200,i250
i200p, i250p
ThisproductcomplieswithANSIZ21.10.3 (2011)/CSA
4.3 GasWaterHeater. Foruse as potablewater heating.
TheEnergyStarratingapplies onlytothei200model.
—Nepasentreposerniutiliserd’essenceou
nid’autresvapeursouliquides inflammables
àproximitédecetappareiloudetout autre
appareil.
QUEFAIRESIVOUSSENTEZUNEODEURDEGAZ
•
Nepastenterd’allumer d’appareil.
•
Net
ouchez àaucuninterrupteur;nepasvous
servirdestéléphonessetrouvantdans
lebâtiment.
•
Appelezimmédiatementvotrefournisseurde gaz
depuisunvoisin.Suivezl
esinstructions
dufournisseur.
•
Sivousnepouvezrejoindrelefournisseur,
appelezleservice desincendies.
—L’installationet l’entretien doiventêtreassurés
paruninstallateurouunserviced’entretien
qualifiéouparlefournisseurdegaz.
AVERTISSEMENT
Assurez-vousdebiensuivrelesinstructionsdonnées
danscettenoticepourréduireauminimumle
risqued’incendieoud’explosionoupour évitertout
dommagematériel,touteblessureoulamort.
1
2
3
56
7
SPARES
4
WARNING
Condensate drain line (2) is shipped from the factory with
a loop held together with plastic ties. Do not remove the
ties and/or straighten the loop. This loop forms an air
block (trap) which prevents carbon monoxide from exiting
the water heater through the drain line. Improper
installation of the drain line can result in excessive levels of
carbon monoxide, which can lead to severe personal injury
or death.
1.2 Contact Information
Call us first if you have any questions about this product. We
can help you with questions about installation or operation,
or if there are damaged or missing parts when you unpack
this unit from the shipping box.
Stamp or write your dealer contact information here for future
reference.
Due to our policy of continuous product improvement and
technology, the design and/or technical specifications are
subject to change without notice.
Serial Number: ___________________________________
Date of Installation: ___ / ___ / ______
1.3 Serial Number Plate Locations
Rating plate contains serial number for the unit. Please
provide this serial number when calling for service or
warranty.
Rating and safety information inside.
(Caractéristiqueset renseignements de sécurité à l'intérieur)
FACTORY PRESET FOR USE WITH
NATURAL GAS
Direct-Vent Automatic Instantaneous Water Heater
(Chauffe-eauautomatique instantané à ventilation directe)
FOR INDOOR INSTALLATIONONLY
(POURINSTALLATION À L'INTÉRIEUR SEULEMENT)
120 Volt,60 Hz, 5 Amps
Type of Gas
(Typede gaz)
:
. . . . . . . . . . . . . . . .
Input Rating
(Entrerle Classement)
: Btu/hr Maximum . . .
Btu/hr Minimum . . .
Maximum Inlet Gas Pressure: . . . . . . . . . . . .
Minimum Inlet Gas Pressure: . . . . . . . . . . . .
Minimum Inlet Gas Pressure (for adjustments): . .
Maximum Water Pressure: . . . . . . . . . . . . .
Minimum Water Pressure: . . . . . . . . . . . . .
Recovery Rating: . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
Thermal Effi
ciency / :
Energy Factor:
NOx Emissions:
. . . . . . . .
(Pursuantto South Coast Air Quality Management District Rule 1146.2)
(Moinsde 20 ppm)
(Jusqu'à98 % / 0.94) (Jusqu'à 98 % / 0.94)
(Moinsde 20 ppm)
(Dégagementsminimums)
(Desnon-combustibles) (D'une construction
combustible)
(conformémentau règlement 1146.2 du "South Coast Air Quality Management District)
Topof heater
Minimum Clearances
From
Non-Combustibles
FromCombustible
Construction
(Dessusdu chauffe-eau)
Backof heater
(Arrièredu chauffe-eau)
Frontof heater
(Avantduchauffe-eau)
Bottomof cabinet
(Côtécanalisation)
Side(Côté)
5/8in (15.8 mm)
6in (15.2 cm)
6in (15.2 cm)
2in (50.8 mm)
12in (30.4 cm)
5/8in (15.8 mm)
6in (15.2 cm)
2in (50.8 mm)
1/2in (12.7 mm)
12in (30.4 cm)
Intellihot Green TechnologiesInc.
2900 W. Main St.
Galesburg, IL 61401
Phone: (877) 835- 1705
Web: www.intellihot.com
Factory Preset
Natural Gas
(Réglageen usine pour gaz naturel)
199,000
20,000
13.0 W.C. (3.20 kPa)
8.0 W.C.(2.00 kPa)
8.0 W.C.(2.00 kPa)
150 psi (1034 kPa)
15 psi (103 kPa)
265 GPH (1003 LPH)
Up to 98% / 0.94
Less than 20 ppm
Field Conversion* to
Propane Gas
(Conversion*sur place au gaz propane)
199,000
20,000
10.5 W.C. (2.62 kPa)
3.0 W.C. (0.76 kPa)
11.0 W.C. (2.74 kPa)
150 psi (1034 kPa)
15 psi (103 kPa)
265 GPH (1003 LPH)
Up to 98% / 0.94
Less than 20 ppm
Check Box if
Convertedto
PropaneGas
*Referto Installation and Operation
manualfor conversion procedure.
(Seréférer au manuel d'installation et
defonctionnement pour la procédure de
conversion.)
PRÉRÉGLAGESD'USINE POUR UTILISATION AVEC
GAZ NATUREL
(Pressionde gaz d'arrivée maximum)
(Pressiond'eau maximum)
(Pressiond'eau minimum)
(Caractéristiquede recouvrement)
(Efficacitéthermique / Facteur énergétique)
(Émissionsde NOx)
(Pressionde gaz d'arrivée minimum)
(Pressionde gaz d'arrivée minimum (pour ajustements))
Cocherla case si converti au gaz propane
ETL STICKER
Serial Number:
IGT-LBL-0005-01
(Numérode série)