Inter-m EVAMATRIX RM-VA1000 Manuale utente

Operation Manual
PUSH
EVAMATRIX System Remote Mic Station
RM-VA1000

EVAMATRIX SYSTEM REMOTE MIC STATION
Welcome
Welcome
A personal welcome to you from the management and employees of Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value,
and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
ATTENTION : RISQUE DE CHOC ELECTRIQUE
NE PAS QUVRIR
WARNING
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.
*Do not install this equipment in a confined space such as a book case or similar unit.
*Warning : To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases,
should not be placed on this apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
*
To completely disconnect this apparatus from the AC mains, disconnect the power supply cord plug from the AC receptacle.
*
The mains plug of the power supply cord shall remain readily accessible.
CAUTION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOTE
*This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
This symbol is intended to alert the user to the
presence of uninsulated “dangerous voltage” within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.
This symbol is intended to alert the user to the
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.
Caution: To prevent electric shock do not use this (polarized) plug with
an extension cord, receptacle or other outlet unless the
blades can be fully inserted to prevent blade exposure.
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre insérées à fond sans en laisser aucune partie à
découvert.
Pour deconnecter completement l’appareil du reseau
d’alimentation. deconnecter le cordon d’alimentation de la
prise murale.
La prise du reseau d’alimentation doit demeurer aisement
accessible.

EVAMATRIX SYSTEM REMOTE MIC STATION
1
RM-VA1000
Contents
Contents
Unpacking .......................................................................................................................................2
Installation
Environment....................................................................................................................................2
Important Safety Instructions.............................................................................................................2
Features ...........................................................................................................................................3
Contents and Accessories .............................................................................................................3
Front Panel ......................................................................................................................................4
Rear Panel .......................................................................................................................................6
How To Set Up The Device And Precautions .............................................................................8
Applications ..................................................................................................................................17
Block Diagram ..............................................................................................................................18
Specifications ................................................................................................................................19
Service
Procedures....................................................................................................................................21
Schematic.....................................................................................................................................21
Parts List .......................................................................................................................................21
Variations and Options...............................................................................................................21
Warranty .......................................................................................................................................21

EVAMATRIX SYSTEM REMOTE MIC STATION
2RM-VA1000
Installation
Unpacking
Unpacking
Although your RM-VA1000 is neither complicated nor difficult to operate, we recommend you take a few
minutes to read this brief manual and familiarize yourself with the important information regarding product
features, setup and operation.
As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
S3125A

EVAMATRIX SYSTEM REMOTE MIC STATION
3
RM-VA1000
Features
Contents and Accessories
Contents and Accessories
1. DC Adapter x 1EA
2. Gooseneck Microphone × 1EA
3. User Manual × 1EA
4. Emergency Broadcasting Label X 1EA
5. Emergency Broadcasting Rear Cover X 1EA
6. 2P Euro Terminal X 1EA
7. AC Cord X 1EA
Features
- PAGING BROADCAST THROUGH NETWORK
RM-VA1000 can connect to our EVAMATRIX System to broadcast paging.
It operates in VA Mode (emergency broadcasting) or PA Mode (normal broadcasting) depending on the menu
settings.
- GOOSENECK MICROPHONE
You can use the gooseneck microphone to broadcast paging in each area.
- 0~9 KEY, ALL, TALK, CHIME KEY
You can select the broadcasting area simply by using the 0 ~ 9 key and the All button. In addition, you can set
the operation of the Talk Key and the Chime Key.
- 2.43 INCH OLED DISPLAY
You can check and set the status of the device through the display.
- OUTPUT LEVEL METER
You can check the output level through the level meter.
- MONITOR SPEAKER
You can check the current output in real time through the monitor speakers.
- INPUT/OUTPUT ADJUSTMENT VOLUME
You can adjust the MIC input gain and monitor speaker output, chime, and AUX volume.
- DC 24 V POWER INPUT
Since there is a DC 24 V power input terminal, you can input the power using the adapter.

EVAMATRIX SYSTEM REMOTE MIC STATION
4RM-VA1000
Front Panel
Front Panel
1. MIC INPUT TERMINAL
This is the terminal to connect the gooseneck microphone.
2. OLED DISPLAY
The organic light-emitting diode (OLED) displays the current status and settings of the device.
3. INPUT SHORTCUT KEY
- When operating in VA Mode
1: Selects Alarm Message emergency broadcast.
2: Selects Alert Message Alarm Message emergency broadcast.
3: Selects Mic Talk Alarm Message emergency broadcast.
4: Stops the buzzer beep sound.
- When operating in PA Mode
1 ~ 5: Input shortcut keys
4. 0 ~ 9 / * / # KEY
They are used to input a number and password.
1
2
3
4
8
9
7
6
5
+3dB

EVAMATRIX SYSTEM REMOTE MIC STATION
5
RM-VA1000
5. TALK KEY
It starts broadcasting after selecting a broadcast area.
6. MENU / PRESET / PREV / NEXT / CHIME / ALL KEY
1) MENU / PREV: They are used to go to MENU and the standby screen.
2) PREV / NEXT: When 8 or more numbers are registered in the number input screen, they are used as
scroll keys.
3) CHIME: It operates the CHIME to notify the start or end of the broadcast.
※It doesn’t work in VA Mode. For more information about Chime Set, refer to 7. SET menu.
4) ALL: This key is used to select all the broadcasting areas.
5) PRESET: It doesn’t work in VA Mode.
7. LED INDICATOR
You can check the output level through the level meter.
8. POWER AND COMMUNICATION LED INDICATOR
It is the LED that shows the power status and communication status. The Power LED is on when power is
supplied, and the communication LED displays the network operation status.
COM1 : LINK/ACT (Flashes when the Ethernet link is up and activity is detected.)
COM2 : GIGA SPEED (Lights up when Ethernet is connected at gigabit speed.)
9. MONITOR / AUX / CHIME VOLUME
This volume controls the MONITOR/AUX/CHIME output.

EVAMATRIX SYSTEM REMOTE MIC STATION
6RM-VA1000
Rear Panel
Rear Panel
1. DC 24V INPUT TERMINAL
This is a DC 24 V power supply terminal. You can input power by using the adaptor.
2. RESET SWITCH
Press more than 10 seconds to reset the device to the factory settings.
3. NETWORK CONNECTING TERMINAL
It is a terminal to connect the device to the network. You can control the broadcasting by using integration
software.
※For more information on how to set up, refer to the integration software manual. Download the manual
at home page. (www.inter-m.net)
12
34 5
GIGA SPEED
LINK/ACT
<100 Base-T> <1G Base-T>
PIN NO
Function
PIN NO
Function
1 TXN 1 MX(0)+
2 TXP 2 MX(0)-
3 RXN 3 MX(1)+
4 NA 4 MX(1)-
5 NA 5 MX(2)+
6 RXP 6 MX(2)-
7 NA 7 MX(3)+
8 NA 8 MX(3)-

EVAMATRIX SYSTEM REMOTE MIC STATION
7
RM-VA1000
※Communication Cable Standards
4. AUX INPUT TERMINAL
You can use this terminal to use the AUX IN jack to input an external sound source and broadcast through
RM-VA1000.
5. MIC GAIN ADJUSTMENT VOLUME
This is the volume that adjusts the input GAIN of the microphone.
UTP
18 18
[ TOP VIEW ]
DIRECT
[ CABLE COLOR ORDER ]
[ FRONT VIEW ]
8.Brown
7.W/Brown
6.Green
5.W/Blue
4.Blue
3
.W
/
G
r
een
3.W/Green
2.Orange
1.W/Orange

EVAMATRIX SYSTEM REMOTE MIC STATION
8RM-VA1000
How To Set Up The Device And Precautions
How To Set Up The Device And Precautions
1. BOOT SCREEN: AFTER THE POWER IS SUPPLIED, AN APPROPRIATE DESCRIPTION IS DISPLAYED ON THE
BOOT SCREEN
- INITIAL SCREEN
1) A “Welcome” message is displayed on the OLED screen when powering up and initializing the
operating system (OS).
2) When the app starts after OS initialization, the message disappears and then reappears after 5 seconds.
3) After displaying the “Welcome” message again, the “Booting …” “Initializing …” message is displayed
on screen.
- STANDBY SCREEN
1) When booting is completed, the standby screen is displayed with the device’s IP information.
※The default IP is 192.168.1.99. You can modify the IP in the device’s web page.
2) To use the RM-VA1000 device, the API Key of the EVAMATRIX integrated management software should
be registered.
※For more information, refer to the software manual.
3) The device and source (RM) should be registered by using the EVAMATRIX integrated management
software.
4) Set the PA Event at the Event & Preset (PA&VA) menu in the EVAMATRIX integrated management
software.
Indice