IPEX PH485REPi Manuale utente

Doc No: PH485REPi-UM-001
USER’S MANUAL
IPEX
(IP Electronix)
15 August 2013
PH485REPi
RS-485 Repeater & Amplifier

www.ipelectronix.com
IPEX (IP Electronix) PH485REPi
: User’s Manual
Page 2 of 8 Doc No. : PH485REPi-UM-001
15 August 2013

www.ipelectronix.com
IPEX (IP Electronix) PH485REPi
: User’s Manual
Page 3 of 8 Doc No. : PH485REPi-UM-001
15 August 2013
Contents
1. INTRODUCTION .......................................................................................................................................4
2. SPECIFICATIONS ......................................................................................................................................4
3. PACKAGE CHECKLIST ...............................................................................................................................5
4. TOP PANEL ..............................................................................................................................................5
5. POWER SUPPLY .......................................................................................................................................5
7. RS-485 CONNECTING METHODS ..............................................................................................................6
8. GUARANTEE ............................................................................................................................................8
9. TECHNICAL SUPPORT...............................................................................................................................8

www.ipelectronix.com
IPEX (IP Electronix) PH485REPi
: User’s Manual
Page 4 of 8 Doc No. : PH485REPi-UM-001
15 August 2013
1Introduction
IPEX PH485REPi™ is a RS-485 Repeater and Amplifier. If it is needed to have RS-485 network with more than
1200m length or to have more than 32 nodes, using a PH485REPi™ helps you to increase the network length up
to 2400m and also to have up to 64 devices connected to it. PH485REPi™ is compatible with RS-485 standard
devices differential Data+ & Data- signals and is fully Plug & Play. It works with a wide range of +10V up to +30V
DC power supply with low (about 40mA) consumption. PH485REPi™ is designed for industrial usage and is
useful for Industrial Automation, Telecommunications, SCADA Systems, and DCS Systems …
Protection against Surge, ESD and EMI is considered in its design and also has 3kV isolation between RS-485
sides. Since RS-485 is a Half-Duplex standard, switching between transmit and receive is done automatically and
no further signal (such as RTS) is required. PH485REPi™ supports Point-to-Point and Point-to-Multi Point Party
Line network topologies.
2Specifications
RS-485 Bidirectional Repeater and Amplifier
Fully Plug & Play
RS-485 Signal: Data+, Data-, GND
Baud Rate Type: Auto Switching Baud Rate
Serial Transmission Speed Up to 230.4 kbps
Maximum Communication Distance: 2400m (8000 feet) – 1200m for each side
Loading: Supported up to 64 Nodes – 32 Nodes for each side
Isolation Protection: 3kV Instantaneous, 500V DC continuous
Power (Green) LED Indicator
Transmit (Blue) and Receive (Yellow) LED Indicator
Power Supply Input Voltage: +10VDC to +30VDC
1 Year Guarantee and 5 Years Support
Operating Temperature: -10°C to +70°C (+14°F to +158°F)

www.ipelectronix.com
IPEX (IP Electronix) PH485REPi
: User’s Manual
Page 5 of 8 Doc No. : PH485REPi-UM-001
15 August 2013
3Package Checklist
Before installing the PH485REPi, verify that the package contains the following items:
1) PH485REPi
2) Installation CD-ROM
3) #2 Phonix 7Pin Green terminals
NOTE: Notify your sales representative if any of the above items is missing or damaged.
4Top Panel
Green LED: It is turned ON, when the power supply connects to +VS and GND correctly.
Yellow LED: It is blinking if there is a data stream from right to left side of the repeater.
Blue LED: It is blinking if there is a data stream from left to right side of the repeater.
5Power Supply
Connect a DC voltage in range of +10V to +30V, between +VS and GND terminals. If the power supply connects
correctly, the Green LED should be ON.
NOTE: It is not required to connect GND signal from one side to GND signal of other side.

www.ipelectronix.com
IPEX (IP Electronix) PH485REPi
: User’s Manual
Page 6 of 8 Doc No. : PH485REPi-UM-001
15 August 2013
7RS-485 Connecting Methods
7.1 RS-485: Point to Point Connection (without Repeater)
7.2 RS-485: Point to Point Connection (with a Repeater)

www.ipelectronix.com
IPEX (IP Electronix) PH485REPi
: User’s Manual
Page 7 of 8 Doc No. : PH485REPi-UM-001
15 August 2013
7.3 RS-485: Multipoint Network (Without Repeater)
7.4 RS-485: Multipoint Network (With a Repeater)

www.ipelectronix.com
IPEX (IP Electronix) PH485REPi
: User’s Manual
Page 8 of 8 Doc No. : PH485REPi-UM-001
15 August 2013
8Guarantee
All products manufactured by IPEXare under warranty regarding defective materials for a period of one year
from the date of delivery to the original purchaser.
9Technical Support
If you have any technical question or need any technical support, please contact us using this Email address:
support@ipelectronix.com.
Indice
Altri manuali IPEX Ripetitore