IPS IPS-600 Manuale utente

Thank you for choosing Full-Inverter heat pump.
This manual provides you necessary information for optimal
use and maintenance, please read it carefully and keep it for
subsequent use.
INSTALLATION AND
USER MANUAL
EN / DE

Summary
1. General information ................................................................................................................ - 1 -
1.1. ontents .............................................................................................................................. - 1 -
1.2. Operating conditions and range ........................................................................................... - 1 -
1.3. Advantages of different modes ............................................................................................. - 2 -
1.4. Kind reminder ....................................................................................................................... - 2 -
2. Operations .............................................................................................................................. - 4 -
2.1. Notice before using .............................................................................................................. - 4 -
2.2. Operation instructions .......................................................................................................... - 4 -
2.3. Daily maintenance and winterizing ....................................................................................... - 7 -
3. Technical specification ............................................................................................................ - 8 -
1. Transportation ......................................................................................................................... - 9 -
2. Installation and maintenance ................................................................................................. - 10 -
2.1. Notice before installation: ................................................................................................ - 10 -
2.2. Installation instruction ......................................................................................................... - 10 -
2.3. Trial after installation .......................................................................................................... - 15 -
2.4. Maintenance and winterizing .............................................................................................. - 16 -
3. Trouble shooting for common faults ...................................................................................... - 16 -
4. Failure code .......................................................................................................................... - 17 -
Appendix 1: Heating priority wiring diagram (Optional) .............................................................. - 18 -
5.
Wifi setting ............................................................................................................................. - 20 -
For users ……………………………………………………………………………….
P.1
-
P.
8
Fo
r installers and professionals
…………
………………………………………
P.
9
-
P.2
5

For users
- 1 -
1. General information
1.1. Contents
After unpacking, please check if you have all the following components.
OR
1.2. Operating conditions and range
Items Range
Operating range Air temp
-7℃~43℃
Temp. setting
heating
18℃~40℃
cooling
12℃~30℃
The heat pump will have ideal performance in the operation range Air 1
℃~
2
℃

For users
- 2 -
1.3. Advantages of different modes
The heat pump has two modes: Smart and Silence. They have different advantages under
different conditions.
1.4. ind reminder
This heat pump has Power-off memory function. When the power is recovered, the heat
pump will restart automatically.
1.4.1. The heat pump can only be used to heat the pool water. It can NEVER be used to
heat other flammable or turbid liquid.
1.4.2. Don’t lift the water union when moving the heat pump since the titanium heat
exchanger inside the heat pump will be damaged.
1.4.3. Don’t put obstacles before the air inlet and outlet of the heat pump.
MODE RECOMMENDATION ADVANTAGES
Smart mode
As standard
Heating capacity: 20% to 100% capacity
Intelligent optimization
Fast heating
Silent mode
Use at night Heating capacity: 20% to 80% capacity

For users
- 3 -
1.4.4. Don’t put anything into inlet or outlet, or the efficiency of the heat pump will be
reduced or even stopped.
1.4.5. Don’t use or store combustible gas or liquid such as thinners, paint and fuel to avoid
fire.
1.4.6. If any abnormal circumstances occurred, e.g.: abnormal noises, smells, smokes and
leakage of electricity, switch off the main power immediately and contact your local
dealer. Don’t try to repair the heat pump by yourselves.
1.4.7. The main power switch should be out of the reach of hildren.
1.4.8. Please cut off the power in the lightning storm weather.

For users
- 4 -
1.4.9. Please note that following codes are not failure.
Description
Codes
No water flow
Anti-Freezing Reminder
Out of the operating range
Insufficient water flow or pump
blocked
Power abnormal
2. Operations
2.1. Notice before using
①
For longer service life, please ensure water pump is on before heat pump is on, and
water pump is off after heat pump is off.
② Ensure no water leakage on piping system, then unlock screen and power on heat
pump.
2.2. Operation instructions

For users
- 5 -
Symbol Designation Function
ON/OFF 1. Power On/Off
2. Wifi setting
Unlock / Mode
1. Press it for 3 seconds to unlock/lock screen.
2. After screen is unlocked, press it to select mode.
Auto (12~40℃) Heating (18~40℃) ooling (12~30℃)
Speed Select Smart/Silence mode
Up / Down Adjust set temperature
Note:
① Screen lock:
a. If no operation in 30 seconds, screen will be locked.
b. When HP is off, screen will be dark and “0%” will be displayed.
c. Press for 3 seconds to lock screen and it will be dark.
② Screen unlock:
a. Press for 3 seconds to unlock screen and it will be lit up.
b. Only after screen is unlocked, any other buttons can be functioned.
Auto
Heating
ooling
Heating capacity percentage
Wifi connection
Water inlet
Water outlet
Water inlet
temperature
Water outlet
temperature
Smart/Silence
mode

For users
- 6 -
1.Power On: Press for 3 seconds to light up screen, then press to power on heat pump.
2.Adjust Set Temperature: When screen is unlocked, press or to display or adjust the set
temperature.
3. Mode Selection: Press to select mode.
a. Auto : adjustable temperature range 12~40℃
b. Heating : adjustable temperature range 18~40℃
c. ooling : adjustable temperature range 12~30℃
4. Smart/Silence mode selection:
①
Smart mode as default will be activated when heat pump is on, and screen shows .
② Press to enter Silence Mode
, and screen shows .
(Suggestion: select Smart mode for initial heating)
5. Defrosting
a. Auto Defrosting: When heat pump is defrosting, will be flashing. After defrosting, will stop
flashing.
b. ompulsory Defrosting: When heat pump is heating, press and together for 5 seconds to
start compulsory defrosting, and will be flashing. After defrosting, will stop flashing.
(Note: ompulsory defrosting intervals should be more than 30 minutes and the compressor should run for
more than 10 minutes.)
6. Temperature display conversion between ℃ and ℉:
Press " " and " " together for 5 seconds to switch between ℃ and ℉.
7. Wifi setting
Please kindly check the last page.

For users
- 7 -
2.3. Daily maintenance and winterizing
2.3.1. Daily Maintenance
Please don’t forget to cut off power supply of the heat pump.
Please clean the evaporator with household detergents or clean water, NEVER use
gasoline, thinners or any similar fuel.
heck bolts, cables and connections regularly.
2.3.2. Winterizing
In winter season when you don’t swim, please cut off power supply and drain water out
of the heat pump. When using the heat pump under 2℃, make sure there is always
water flow.
Important:
Unscrew the water union of inlet pipe
to let the water flow out.
When the water in machine freezes in
winter
season, the titanium heat
exchanger may be damaged.

For users
- 8 -
3. Technical specification
Model IPS-600 IPS-1200
Advised pool volume (m
3
) 130~260
260~520
Operating air temperature (℃) -7~43
Performance Condition: Air 26°C, Water 26°C,
Humidity 80%
Hea
ting capacity (kW)
60.0
110.0
OP at 50% capacity 10.1 10.0
Performance Condition: Air 15°C, Water 26°C,
Humidity 70%
Heating capacity (kW)
40.0 81.0
OP at 50% capacity 6.8 6.8
Performance Condition: Air 35°C, Water 28°C, Humidity 80%
ooling capacity (kW) 26.5 54.0
Sound pressure at 1m dB(A) 54.0~62.0 56.0~65.0
Sound pressure of 50% capacity at 1m
dB(A) 56.0 58.0
Sound pressure at 10m dB(A) 34.0~42.0 36.0~45.0
ompressor D inverter
Heat exchanger Spiral titanium tube in PV
asing Aluminum-alloy
Fan direction Vertical
Power supply 400V/3Ph/50Hz
Rated input power at air 15° (kW) 2.20~8.03
4.69~17.6
Rated input current at air 15° (A) 3.17~11.59
6.77~25.4
Advised water flux (m³/h) 20~25
40~50
Water pipe in-out size (mm) 75
110
Net dimension LxWxH (mm) 1110x1023x1260
2100×1090×1280
Net weight (kg) 230
448
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover,
filtration system running at least 1 hours a day.
Related parameters are subject to adjustment periodically for technical improvement without
further notice. For details please refer to nameplate.