IRIS Touch 200 Manuale utente

200 Range Dialer
Installation Manual
Version 1.0

The information contained is supplied without liability for any errors or
omissions. No part may be reproduced or used except as authorised by contract
or other written permission. The copyright and foregoing restriction on
reproduction and use extend to all media in which the information may be
embedded.
© 2008 Chiron Technology Ltd


Iris Touch 200 Range Dialer Installation Manual i
Contents
1. Introduction ...................................................................................................... 1
1.1. About this manual… .............................................................................. 1
1.2. Overview ................................................................................................ 1
1.3. System specifications ............................................................................ 2
2. Before you start…............................................................................................ 3
2.1. Package contents .................................................................................. 3
2.2. Pre-requisites......................................................................................... 3
3. Alarm dialer interface....................................................................................... 4
4. Installing the IRIS Touch Dialer....................................................................... 4
5. Configuring the IRIS Touch Dialer .................................................................. 7
6. Post installation................................................................................................ 8
7. PIN alarms ....................................................................................................... 8
7.1. Installation .............................................................................................. 9
7.2. Default alarm messages...................................................................... 10
8. Relay outputs ................................................................................................. 10
9. Troubleshooting ............................................................................................. 10
Appendix A – Settings menu................................................................................. 11
Appendix B – Installation photos .......................................................................... 12
Appendix C – Specification ................................................................................... 14

Iris Touch 200 Range Dialer Installation Manualii

Iris Touch 200 Range Dialer Installation Manual
1
1. Introduction
1.1. About this manual…
This manual is designed to help you, the Installer, with the installation process
for the IRIS Touch alarm dialer. We recommend that you read through this
manual, in its entirety, before you visit the customer’s site and begin the
installation.
1.2. Overview
The IRIS range of alarm dialers allow users to migrate intruder alarm systems
away from traditional PSTN communications to IP based and/or wireless
networks, without the need to upgrade or replace the alarm system.
The majority of intruder alarm systems which are configured to make alarm calls
to a central monitoring station use the traditional PSTN analogue network as the
communications path. However, PSTN is becoming increasingly unsuitable as
users move to IP and Voice over IP (VoIP) for their fixed networks or rely purely
on mobile (GSM and GPRS) communications. In addition most PSTN service
providers are migrating to VoIP networks, so in the not too distant future PSTN
lines may be withdrawn.
The IRIS dialer range is unique in offering a quick and cost effective way to
interface any existing alarm system to alternative networks such as GSM,
Ethernet and GPRS. As a result of the flexibility and power of IRIS it has
become the IP transmission system of choice for Monitoring Centres across
Europe.
The IRIS 200 series is intended to be used with alarm panels that do not have
sufficient space inside their enclosures for an IRIS dialer. There are three
dialers in the range:
•IRIS Touch 200 - GSM
•IRIS Touch 220 - Ethernet
•IRIS Touch 240 - Ethernet & GPRS
The IRIS Touch dialer should be located next to the alarm panel and powered
from the panel’s internal battery backed DC supply.

Iris Touch 200 Range Dialer Installation Manual2
1.3. System specifications
Feature Touch 200
GSM
Touch 220
Ethernet
Touch 240
Ethernet &
GPRS
Stylish, tamper proof enclosure
Easy to install and test with touch
screen interface
2-wire (POTS) analogue interface
to standard alarm dialers
Support for SIA (1-3), Contact ID,
Scancom (Fast Format) and
Robofon protocols
Pin inputs for alarm messages
over SMS
444
Relay contact outputs 2 2 2
9-30V DC power from alarm panel
USB port for local configuration
Secure polling (monitoring) over
Ethernet
Secure alarm transmission over
Ethernet
Pin inputs for alarm messages
over Ethernet or GPRS
44
Configuration and diagnostics over
Ethernet
Secure polling (monitoring) over
GPRS
Secure alarm transmission over
GPRS
Configuration and diagnostics
over GPRS
Alarm transmission over GSM

Iris Touch 200 Range Dialer Installation Manual 3
2. Before you start…
2.1. Package contents
In this package you should have the following components:
•Main dialer unit comprising:
•PCB with 3 part plastic enclosure (back, front and slider).
•4 x assembly screws.
•2 x tamper switch springs.
•Power cable (black) for connection to DC supply.
•Ethernet cable (cream) for connection to IP network. (Ethernet /
Ethernet & GPRS only).
•Antenna for GSM/GPRS. (GSM / Ethernet & GPRS only).
•Dialer cable (grey) for connection to dialer output of alarm panel.
•Screws and plugs (3 of each) for wall mounting.
•Sense resistor (18K ohm) for alarm dialer cable fault/tamper detection.
•Installation manual.
2.2. Pre-requisites
For installations using IP (Ethernet) or GPRS you must ensure you have the
following:
•The IP address for the Monitoring Centre.
•Confirmation that the Monitoring Centre is set up and ready for the
account number or name to be used for this IRIS dialer.
•The type of IP address (either automatic or fixed) for the installation
site. If the site has a fixed IP address, you should get this information
from the customer in advance, together with the Gateway Address and
the Subnet Mask for the IRIS dialer.
•An additional long Ethernet cable, in case the installation site requires
one longer than that supplied with the IRIS dialer.
•A SIM card enabled for GPRS with the PIN code clear. (Ethernet &
GPRS only.)
•The GPRS Access Point Name (APN) of the SIM card provider. Some
networks also require a User Name and Password which can also be
obtained from the SIM card provider. (Ethernet & GPRS only.)

Iris Touch 200 Range Dialer Installation Manual4
3. Alarm dialer interface
IRIS dialers carry alarm signals from the alarm panel over IP completely
transparently so when they arrive at the Monitoring Centre it is as though they
had come over a traditional PSTN connection. IRIS dialers support SIA (Levels
1 to 3), Contact ID, Scancom (Fast Format) and Robofon protocols, one of
which virtually all alarm panels will support.
Apart from the following, no reconfiguration of the alarm panel is required for
use with IRIS dialers:
1. If alarm signalling over Ethernet or GPRS is required, change the setting in
the alarm panel for the telephone number to be dialled for alarm signalling.
This number should be changed to the IP address of the Monitoring Centre,
entered as 12 digits. Each of the four IP address numbers separated by a ‘.’
should be entered as a 3 digit number, with leading ‘0’s as required, and
the ‘.’s should be excluded. For example:
IP address 10.1.146.22 is entered as 010001146022.
If the Monitoring Centre requires a backup IP address to be entered, this is
done in the same way.
2. If alarm signalling over GSM is required, add a leading digit ‘7’ to the
normal PSTN telephone number of the Monitoring Centre.
3. If the panel is required to make outgoing calls over IP for upload/download
or remote configuration, then where the telephone number for this would
normally be entered, put in the digit ‘8’ followed by the destination IP
address in 12 digit format, as above.
4. Installing the IRIS Touch Dialer
Use the following procedure to install the IRIS Touch Dialer.
Note: For installations using PIN alarm inputs see the PIN alarms section for
additional information and for wiring to relay outputs see the Relay outputs
section.
Do not apply power to the dialer until indicated.

Iris Touch 200 Range Dialer Installation Manual 5
1. Decide where to run the cables
Decide the best way to run the cables to the PCB. This can be either:
•Behind the unit (through the wall).
•Through the bottom of the back plate of the unit (via the ‘knock outs’).
2. Disassemble the unit
Remove the two case fixing screws [1] and open the unit [2]. Remove the
two PCB fixing screws [3] and remove the PCB.
3. Mount the unit on the wall
Position the back plate on the wall, drill 3 holes, put the cables through the
opening at the base of the plate [4], or via the ‘knockouts’ [5], and secure
the plate to the wall with the 3 screws supplied [6].
4. Plug in the connectors
Connect the relevant cables to the PCB:
•Ethernet cable (cream) [7] (Ethernet / Ethernet & GPRS only)
•Dialer cable (grey) [8]
•Power cable (black) [9]
5. Install the antenna (GSM / Ethernet only)
Position the antenna in the groove in the back plate of the unit [10] and
connect the antenna to the PCB [11].
Note: Alternatively you can use an external antenna if the location of the
internal antenna does not give sufficient signal.
6. Fit the tamper switch springs
The IRIS dialer is protected against tampering (e.g. removal from the wall
or opening of the case) by two tamper switches [12] – one either side of the
PCB. These switches are held by springs that press against the wall and
the top cover.
Before fitting the PCB, make sure the springs that come with the unit are
fitted correctly to the tamper switches.
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali IRIS Sistema di sicurezza
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente