iSolution Xperior 300A Beam Manuale utente

XperiorTM 300A Beam
User Guide
Please read these instructions carefully before use

1

XP-300A Beam
2-
TABLE OF CONTENTS
1. Safety Instruction...................................................................................... 3
2. Installation ................................................................................................. 5
3. Technical Specification ............................................................................ 6
4. Description ................................................................................................ 9
4.1 Description of the fixture..........................................................................................9
4.2 Control Panel...........................................................................................................9
5. Gobo and Lamp....................................................................................... 10
5.1 Inserting/Exchanging rotating gobos .....................................................................10
5.2 Lamp .....................................................................................................................11
6. How To Set The Unit ............................................................................... 13
6.1 Power On Display..................................................................................................13
6.2 Main Function ........................................................................................................13
6.3. Home Position Adjustment ...................................................................................23
6.4. Error Information...................................................................................................26
7. Control By Universal DMX Controller ................................................... 27
7.1 Connection ............................................................................................................27
7.2 Channel Mode Setting ...........................................................................................28
7.3 Address Setting .....................................................................................................29
7.4 DMX 512 Configuration .........................................................................................29
8. Update Software...................................................................................... 35
9. Troubleshooting...................................................................................... 35
10. Maintenance and Cleaning................................................................... 36

XP-300A Beam
3-
1. Safety Instruction
WARNING
Please keep this User Guide for future consultation. If you sell the unit to another user, be
sure that they also receive this instruction manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty.
The dealer will not accept liability for any resulting defects or problems.
yUnpack and check carefully that there is no transportation damage before using the
unit.
yThe unit is for indoor use only. Use only in a dry location.
yDo install and operate by qualified operator.
yDo not allow children to operate the fixture.
yUse safety chain when fixing the unit. Handle the unit by carrying its base instead of
head only.
yThe unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces.
yBe sure that no ventilation slots are blocked, otherwise the unit will be overheated.
yBefore operating, ensure that the voltage and frequency of power supply matches the
power requirements of the unit.
yIt’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
yMaximum ambient temperature TA: 40 . Don’t operate it℃when the temperature is
higher.
yDon’t connect the device to any dimmer pack.
yDuring initial start-up some smoke or smell may arise. This is a normal process and
does not necessarily mean that the device is defective, and it will decrease gradually
within 15 minutes.
yMake sure there are no flammable materials close to the unit while operating to avoid
fire hazard.
yExamine the power wires carefully; replace them immediately if there is any damage.
yUnit’s surface temperature may reach up to 85 . Don’t touch the housing bare℃-handed
Please read carefully the instruction manual, which includes important
information about the installation, usage and maintenance.

XP-300A Beam
4-
during its operation, and allow about 15 minutes for cooling the unit down before
replacing bulb or maintenance as it could be very hot.
yAvoid any inflammable liquids, water or metal objects entering the unit. Once it
happens, cut off the mains power immediately.
yDo not operate in dirty or dusty environment; do clean the fixture regularly.
yDo not touch any wire during operation as there might be a hazard of electric shock.
yAvoid power wires twist other cables.
yThe minimum distance between light output and the illuminated surface must be more
than 2.5 meters.
yDisconnect mains power before fuse/lamp replacement or servicing.
yReplace fuse/lamp only with the same type.
yIn the event of serious operating problem, stop using the unit immediately.
yNever turn on and off the unit time after time.
yThe housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
yDo not open the unit as there are no user serviceable parts inside.
yNever try to repair the unit by yourself. Repairs carried out by unskilled people can lead
to damage or malfunction. Please contact the nearest authorized technical assistance
center if needed.
yDisconnect the mains power if the fixture is has not been used for a long time.
yDo use the original packing materials before transporting it once again.
Caution
yTo prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
yHot lamp explosion hazard. Do not open the unit within 15 minutes after switching off.
yDo replace the bulb once it is damaged, deformed or life-expired.
yDo not look directly at the light while the bulb is on.
yNever touch bulb with bare fingers, as it is very hot after using.
yDo not start on the unit without bulb enclosure or when housing is damaged.
Due to the magnifying type lens, please keep the lens out of contact
with direct sunlight. Direct sunlight can cause heat to build up inside
of the unit, which will seriousl
y
dama
g
e the unit.

XP-300A Beam
5-
Product Items
yUser manual
y2 x Omega clamps
2. Installation
Unpacking the fixture (for flight case pack only)
1.Stop the flight case via the brake sheet above the wheels.
2.Unlock the lock modules (1) and open the cover board.
3.Prop the cover board with lid bracket.
4.Take out the fixture.
5.Unlock the lock module (2) take out omega clamps.
Installation:
1. Bolt each clamp (1) to the Omega holder with screw and lock nut through the hole in the
holder.
2. Fasten the omega holders (2) on the bottom of the base by inserting quick-lock
fasteners (3) into the holes of the base and tighten fully clockwise.
3. Hang the fixture to the support (4) through clamp and fasten the screws (5). Fasten the
safety cable (6) through the bottom of the base and over the support.
Fig.1 Fig.2

XP-300A Beam
6-
Attention:
yAlways ensure that the structure to which you are attaching the unit is secure and is
able to support a weight of 10 times of the unit’s weight without any harming
deformation.
yAlso always use a safety cable that can hold 12 times of the weight of the unit when
installing the fixture.
yMake absolute sure that the unit is firmly fixed in way that no vibrating or slipping would
occur during operation.
yThe equipment must be installed beyond the areas where persons may walk by or be
seated.
yThe rigging has to be operated by or under the guide of a skilled person.
3. Technical Specification
Power supply
- AC 100~240V 50/60Hz
Power Consumption
- 416W (230V)
- 434W (120V)
Fuse
- T 10 A
Lamp
- Philips MSR Gold 300/2 miniFastFit
Battery backup display
- Setting DMX address or other functions without connecting to mains power.
-Battery for LCD display charges automatically when the fixtures connects to the mains
power.
- No need to change battery.
Wireless control (for the unit with wireless receiver built-in only)
- Wirelessly controlled by W-DMX (option).
- Each W-DMX is sending out 512 channels of DMX.
-License free band of 2.45 GHz

XP-300A Beam
7-
Optical system
- High efficiency optical system, delivering extremely powerful output
- High quality dichroic lenses
- Beam angle: 8°
Movement
- Pan: 540°
- Tilt: 270°
- Pan/Tilt moving speed adjustable.
- Automatic Pan/Tilt correction.
- Easy calibration and maintenance by magnetic home positioning.
- Pan/Tilt position lock for transporting protection.
Dimmer/Shutter
- Blackout, 0~100% smooth dimming, independent shutter and various strobe effect.
Color wheel
- Color wheel: 7 dichroic colors + open.
- Rainbow effect in both directions.
- Easy calibration and maintenance by magnetic home positioning.
CMY
- CMY speed adjustable.
- Optional multiple preset colors and macros available.
Gobo wheel
- Gobo size: Ø26.8mm (Ø24mm for image)
- Gobo Wheel: 7 rotating, indexable, easily replaceable gobos + open.
- Easy calibration and maintenance by magnetic home positioning.
- Module design for easy assembly and service.
Prism
- 3 facets prism with rotating effect.
Frost
- Frost effect.
Cool
- Fan cooled
Protocols
- DMX 512

XP-300A Beam
8-
- Date input/output: 3/5 Pin XLR socket
Dimension
- 447 × 369 × 604 mm
Weight
- 21kgs
Photometric diagram
DMX Channels
Mode
CH
Mode 1
18-CH
Mode 2
18-CH
Mode 3
25-CH
1 Pan Shutter Pan
2 Pan Fine Dimmer Pan Fine
3 Tilt Cyan Tilt
4 Tilt Fine Magenta Tilt Fine
5 Pan /Tilt Speed Yellow Pan /Tilt Speed
6 Shutter Color Dimmer
7 Dimmer Gobo Dimmer Fine
8 Color R-Gobo Shutter
9 Cyan R-Gobo Fine Color
10 Magenta Prism Cyan
11 Yellow R-Prism Magenta
12 Preset Color Pan Yellow
13 Gobo Pan Fine CMY Speed
14 R-Gobo Tilt Gobo
15 Prism Tilt Fine R-Gobo
16 R-Prism Pan /Tilt Speed R-Gobo Fine
17 Frost Frost Prism
18 Function Function R-Prism
19 R-Prism Fine

XP-300A Beam
9-
20 Frost
21 P/T Macro
22 P/T Macro Speed
23 Preset Color
24 Color Macro
25 Function
4. Description
4.1 Description of the fixture
The head can be locked for transportation protection-the tilt lock button (4) is pressed and
the pan lock/unlock lever (6) is in lock position. To unlock the head, press the tilt unlock
button (5) and move the pan lock/unlock lever (6) to unlock position.
Caution: The head and arm must be unlocked before operation!
4.2 Control Panel
Front view Rear view
○
1 Monitor (Batter Back-up display):
1.Arm
2.Front panel
3.head
4.Tilt lock button (Black)
5.Tilt unlock button (Gray)
6.Pan lock
7.Handle
8.Base
9.Antenna (for XP-300A BEAM WT only)
Indice
Altri manuali iSolution Attrezzatura di illuminazione

iSolution
iSolution IR-7S Manuale utente

iSolution
iSolution IM-5W Manuale utente

iSolution
iSolution iRock-5S-HID Manuale utente

iSolution
iSolution IM-250SW Manuale utente

iSolution
iSolution Xperior 300SZ Spot Manuale utente

iSolution
iSolution iMove 50S Manuale utente

iSolution
iSolution Lighting Equipment Manuale utente

iSolution
iSolution IMOVE 250W Manuale utente

iSolution
iSolution iMOVE 8W Manuale utente

iSolution
iSolution IR-575S Manuale utente