ITW Simco-ion IQ Power MPS Manuale utente

IQ POWER MPS POWER SUPPLY 5201279 Rev A
IQ PowerTM
Static Neutralizing System
MPS Power Supply
INSTALLATION AND OPERATING INSTRUCTIONS

i
IQ POWER MPS POWER SUPPLY 5201279 Rev A
TABLE OF CONTENTS
1. SAFETY WARNINGS ........................................................................... 1
2. DESCRIPTION .................................................................................. 2
Features .................................................................................................................................3
3. SPECIFICATIONS................................................................................ 4
4. INSTALLATION .................................................................................. 5
Initial Considerations .........................................................................................................11
Mounting the Static Neutralizing Bar ...............................................................................12
Mounting the Power Supply ..............................................................................................13
Electrical Connections .......................................................................................................13
Power Supply Number (Address / Device Number) ..........................................................16
Set Up (with IQ Power Control Station) ............................................................................16
5. OPERATION ..................................................................................... 19
Power Supply Indicators ....................................................................................................19
Power Supply Operators ....................................................................................................19
System Start-up ..................................................................................................................19
Static Bar Operation ...........................................................................................................20
System Operation (with IQ Power Control Station)...........................................................20
6. MAINTENANCE .................................................................................21
Cleaning the Static Bar ......................................................................................................21
7. TROUBLESHOOTING ..........................................................................23
8. PARTS AND ACCESSORIES...................................................................24
9. WARRANTY AND SERVICE ...................................................................25

1
IQ POWER MPS POWER SUPPLY 5201279 Rev A
1. SAFETY WARNINGS
PLEASE READ INSTRUCTIONS COMPLETELY BEFORE STARTING
INSTALLATION.
ALL INSTALLATION AND TROUBLESHOOTING OPERATIONS MUST
BE PERFORMED BY QUALIFIED TECHNICAL PERSONEL.
This instruction manual uses symbols to identify dangerous situations as follows:
NOTE – Statements identified with a NOTE indicate precautions necessary
to avoid potential equipment failure.
CAUTION – Statements identified with a CAUTION indicate potential
safety hazards.
WARNING – Statements identified with a WARNING indicate potential
safety serious injury hazards.
NOTE – This equipment must be correctly installed and properly
maintained. Adhere to the following notes for safe installation and operation:
1. Read instruction manual before installing or operating equipment.
2. Only qualified service personnel are to perform installation and repairs.
3. All equipment must be properly grounded, including the machine frame to which
the equipment is mounted.
4. Turn off or disconnect input power to power supply before connecting or
disconnecting static neutralizing bars to the high voltage power supply.
5. Do not operate system in close proximity to flammable liquids.
CAUTION – This product is intended to be supplied by a Listed AC
Adapter or Power Unit marked “Class 2” or “LPS” and rated output 24V
1.7A, as provided. Negative must be grounded.
CAUTION – Electrical Shock Hazard
Disconnect input power to high voltage power supply before connecting
or disconnecting static neutralizing bar or performing any maintenance to
the system. Avoid touching static neutralizing bar when power supply is
energized.
WARNING – Fire Hazard
Do not install or operate static neutralizing bar in close proximity to any
flammable liquids or solvents.

2
IQ POWER MPS POWER SUPPLY 5201279 Rev A
2. DESCRIPTION
Simco-Ion’s IQ Power MPS Static Neutralizing System consists of a high voltage
power supply, static neutralizing bar, and the following optional devices: control
station, and static sensing bar. The MPS is typically used in conjunction with the
LP bar. The IQ Power LP static bar features a low profile and plug-in style high
voltage connector that is compatible with other power supplies in the IQ Power line.
The IQ Power LP is a speed type static bar. The IQ Power Control Station provides
the ability to both monitor and control real time system performance. The IQ Easy
Static Sensor Bar enhances the Control Station’s ability to both monitor and control
the static eliminating performance of the MPS.
The high voltage power supply module provides microprocessor controlled high
voltage DC output to the static bar. The high voltage causes the ionizing pins on
the static bar to generate positive and negative ions. The electric field from the static
charge on the material being processed attracts opposite polarity ions from the static
bar causing the material to be neutralized. Excess ions will either recombine in air
or dissipate to ground.
The LP static neutralizing bar features current limiting at each individual ion
emitting pin to minimize the risk of hazardous electrical shock if the bar is touched
while in operation. This safety feature does not compromise the IQ Power system’s
ability to neutralize static charges. The emitter pins are made of tungsten to extend
the longevity and sharpness of the points, providing optimal performance of the
static bar.
The IQ Power MPS may be powered independently with an AC adapter or as part of
an IQ Power system from the Control Station. When part of an IQ Power system,
a pre-terminated cable with M12 connectors is used for connection to the Control
Station. These cables provide power and communication for the IQ Power MPS.
For details on these cables, contact Simco-Ion customer service (800) 203-3419
(refer to Section 8, Parts and Accessories).
The Control Station is a convenient hub that provides power and communication
for up to ten IQ Power or IQ Easy devices. The two-way digital communication
provided by the Control Station enables monitoring and logging of system
performance and allows access to enhanced features in the static neutralization
system. These enhanced features include; manual control of ionization balance,
Auto-Tune automatic control of ionization balance, and CLFB (Closed Loop Feed
Back) providing the ultimate in static eliminator control (use of the IQ Easy Static
Sensor Bar is required).
The Control Station may also be configured with a port for an Anybus® CompactCom
module. This module provides interface with a wide variety of standard industrial
computer communication protocols allowing easy integration of the IQ Power static
neutralizing system with existing networks.
Anybus® CompactCom is a registered trademark of HMS Industrial Networks.

3
IQ POWER MPS POWER SUPPLY 5201279 Rev A
Features
• The IQ Power LP static neutralizing bar features a low profile.
• Static bar disconnect plug pre-installed on static bar cable for quick and
easy installation.
• Ionization emitter points current limited to enhance operator safety.
• Ionization emitter points of tungsten to extend operating life of emitter
points.
• Continuous mounting slot on static bar and mounting brackets for easy and
flexible installation.
• Indicators on power supply display status of neutralizing system and
detection of system faults.
• Connection available on power supply for remote sensing, alarm status and
standby control of power supply.
• Optional control station that provides power and a communication hub for
IQ Power static neutralizing systems.
• Optional static sensor bar for gathering web charge data (used in CLFB
mode).

4
IQ POWER MPS POWER SUPPLY 5201279 Rev A
3. SPECIFICATIONS
MPS Miniature Power Supply
Input Power 24 VDC, 1A (max) , negative ground, from AC adapter or Control Station
Output Voltage +/-7.5 kV
Dimensions 6.59”L x 3.09”W x 1.50”H [167.4L x 78.4 W x 38.1H mm] (not including
mounting ears)
Weight 14 oz [390 g]
Operating Temp 43°C [110°F] max
Enclosure Glass-ber-reinforced Polycarbonate
High Voltage Connectors 1 proprietary IQ Power plug-in outlet
LP Low Prole Static Neutralizing Bar
Overall Bar Length 300-3960 mm [11.8-156”]
Prole Dimensions 34W x 19H mm [1.34”W x 0.75”H]
Weight 0.6 g/mm [0.5 oz/in)
Operating Temp 80°C [176°F] max
Humidity 70% RH max, no dewing permissible
Enclosure Glass-ber-reinforced Polycarbonate
HV Cable Length 3m [10’] standard
Emitter Material Tungsten
Emitter Spacing 30 mm [1.18”]
Operating Distance 50-230 mm [2-9”]
Installation Hardware Plastic mounting brackets, metal perforated strips and stainless steel
hardware (screws, washers, nuts).
AC Adapter
Type “Universal”desktop
Input Power 100-240V 50/60 Hz input (IEC 320 inlet)
Part Number 4110732
Output 24V, 1.7A maximum
Dimensions 4.33”L x 2.05”W x 1.26”H [110L x 52W x 32H mm]
Weight 5.3 oz [150 g]
Enclosure Thermoplastic, black

5
IQ POWER MPS POWER SUPPLY 5201279 Rev A
4. INSTALLATION
Figure 1. IQ Power LP Static Bar Installation
Figure 2. IQ Power LP Static Bar Bracket

6
IQ POWER MPS POWER SUPPLY 5201279 Rev A
Figure 3. IQ Power LP High Voltage Connector
Figure 4. IQ Power MPS Dimensions

7
IQ POWER MPS POWER SUPPLY 5201279 Rev A
Figure 5. IQ Power MPS Connections (Bar and Power Supply)

8
IQ POWER MPS POWER SUPPLY 5201279 Rev A
Figure 6.Typical IQ Power MPS to Control Station Cables
Questo manuale è adatto per i seguenti modelli
5
Indice
Altri manuali ITW Alimentazione elettrica

ITW
ITW Simco-Ion S165S Manuale utente

ITW
ITW Simco-Ion D167Q Manuale utente

ITW
ITW Simco-Ion IQ Power HL Manuale utente

ITW
ITW SIMCO ION D Series Manuale utente

ITW
ITW Orbitalum ORBIMAT 165 CA Manuale utente

ITW
ITW SIMCO ION IQ Power BPS-C Manuale utente

ITW
ITW Simco-Ion Chargemaster Pinner Superbar Manuale utente

ITW
ITW Simco-Ion Chargemaster VCM30 Series Manuale utente

ITW
ITW Simco-Ion Dual Phase+ Manuale utente