Page 1of 6
Model No : JA-SPB-N,JA-SPB-L
INSTALLATION INSTRUCTIONS
UNIT TO BE INSTALLED BY AUTHORISED PERSONNEL ONLY
REFER TO THE DATA PLATE FOR GAS TYPE AND PRESSURE DETAILS
Gas point access on the right unit is almost 150mm from the right side x 330mm over floor x
110mm in from the back of the appliance. The gas point connection is a ¾ B.S.P (20mm) into a
regulator.
The installer is to provide and install an isolating gas cock to each device channel for the comfort
of maintaining the control system. N.B. WARNING each product must have a different inlet
wiring.
The installer must set the appliance according to AS/NZS 5601, local authority, gas and any
other relevant statutory regulations.Confirm to install the device in a non-flammable area
beside the unit. Approval from flammable walls sides left and right 350mm, approval from the
approval from theback of unit 150mm, top of 1500mm. The installer must look at local
building guidelines on non-flammable structural substance specifications.
Take out any transportation packaging for this product before installation.
WATER CONNECTION
330mm above the floor x 430mm in from the right side 17mm compression fitting is given for
connection to the water supply. The installer is to provide an isolating stop tap to the device.
Before being done with the setup, look at all gas and water installations for leaks. Direct the
operator in lighting up and use of the machine. NOTE: This appliance must always be placed on
foldable legs as supplied.
You must set the gas pressure as per the info on the data plate when the product is in operation.