JCM Technologies M42 Manuale utente

M42
User Manual

Table of contents
Important safety instructions 3
Safety instructionsfor installation 3
Safety instructionsfor the use 4
Use of the equipment 4
Introduction 5
General description 5
Detailed description 5
Indication LEDs 6
Installation 7
Connections 7
Configuration 9
Optionsselector 9
Starting up 10
Door Positioning 10
Programming 11
Maneuver programming with twomotors with slowspeed 11
Maneuver programming with twomotors without slow speed 12
Maneuver programming with one motor with slow speed 12
Maneuver programming with one motor without slow speed 12
Maneuver programming with absolute encoder (just motor 1) 12
Troubleshooting 13
Indicator light for possible faults, LED ERROR 13
Notes 15
Technical Data 16
Regulatory Data 16
UKDeclaration of conformity 16
EU Declaration of conformity 16
jcmtechnologies
2

Important safety instructions
Safety instructions for installation
Disconnect the power supply whenever you proceed to the installation,
maintenance or repair of the equipment.
•Before installing the panel, remove all unnecessary ropes or chains and disable any equipment such as locks that is not
necessary for the automatic operation.
•Before installing the panel, check that the door is in good mechanical condition, correctly balanced and that it opens and
closes correctly.
•Install the manual unlocking device at a height lower than 1.8m.
•Install any permanent control next to the door away from any moving part and at a minimum height of 1.5m.
•For permanently connected equipment, an easily accessible power disconnection device must be incorporated into the wir-
ing. It is recommended that this be of the emergency switch type.
•If the control panel is supplied without emergency stop button, this will be incorporated in the installation, connecting it to
the STOP terminal.
•For correct use of the security edge, this must never be activated when the door is fully closed. It is wise to install the ends
of run before activating the edge.
•This equipment can only be handled by a specialist fitter, by maintenance staff or by a suitably trained operator.
•To connect the power supply and motor wiring, 2.5 mm2 section terminals must be used.
•Use protective goggles when handling the equipment.
•Fuses must only be handled when the appliance is disconnected from the mains.
•The instructions for using this equipment must remain in the possession of the user.
•European door normative EN 12453 and EN 12445 specify the following minimum protection and door safety levels:
- for single-family dwellings, prevent the door from making contact with any object or limit the force of contact (e.g. safety
band), and in the case of automatic closing, it is necessary to complement this with a presence detector (e.g. photocell).
- for communal and public installations, prevent the door from making contact with any object or limit the force of contact
(e.g. safety band), and complement this with a presence detector (e.g. Photocell).
M42 control panel switches automatically to dead man mode when safety devices are active or
defective. Therefore, all controls work as “hold-to-run” controls.
WARNING: IN ACCORDANCE WITH THE EN 13241-1 AND EN 12453-1 STANDARD
CONCERNING PRESSURE MAINTAINED CONTROL DEVICES:
“The person operating the door must have a direct view of the doorway, must be near the door (5 meters maximum) during
movement of the door and should not find itself in a dangerous position”. Any adjustment of the radio range out of these
recommendations, undertakes the installer in terms of responsibility for injury or damage.
“Releasing of the pressure maintained control device should stop the door movement before it scrolls 5cml”.
jcmtechnologies
3

Safety instructions for the use
•Do not allow children to play with the door controls.
•Keep the remote controls out of the reach of children.
•Watch the door movement and keep people away until the door is fully open or closed.
•Precaution when operating the manual unlocking device, as the door may suddenly fall due to the bad condition of the
springs or door unbalance. Details on how to use the manual unlocking device must be provided by the manufacturer or the
device installer.
•Examine the installation frequently, especially the cables, springs and supports, to detect signs of wear, damage or unbal-
ance. Do not use the door if repair work or adjustments are required, as this may cause damage.
Use of the equipment
Designed for automation of garage doors, in accordance with the general description. Not guaranteed for other uses. The
manufacturer reserves the right to alter equipment specifications without prior notification.
jcmtechnologies
4

Introduction
General description
Single-phase control panel with 2 motors with soft stop for residential and community use. Control by JCM, Elektromaten or
Kostal digital absolute encoder (motor 1 only) or by limit switches.
Detailed description
1- RECEIVER 12- 12/24VDC / TEST OUTPUT
Motion STICK receiver connector 2 outputs
12Vac/dc range: 11,4V to 12,6V
24Vac/dc range: 23,9V to 27,3V
2- MOTOR POWER 13- ELECTROLOCK
Electrolock 12Vdc output
3- EXPANSION CARD 14- FREE VOLTAGE OUTPUTS
TL-CARD-V / RSEC3 Connector Voltage-free outputs (voltage-free relay contacts, sup-
ply them at 110-230Vac or 12 / 24Vac / dc as desired)
4- DOOR POSITION BUTTONS 15- MOTOR 2 CONNECTION
Position open and close door for each motor Connection for motor 2
5- ALTERNATIVE BUTTON 16- MOTOR 1 CONNECTION
Start maneuver Connection for motor 1
6- PROGRAMMING BUTTON 17- POWER SUPPLY
(Maximum time: 6 min) 110V - 230Vac
50Hz - 60Hz
7- OPTION SELECTORS 18- EMERGENCY
(see"Connections") Emergency button connection
8- REMOTE CONNECTOR 19- FUSE
Connection for VERSUS-PROG programmer 6A/250V delayed
9- INPUTS 20- GARAGE LIGHT
Connection for inputs, limit switches or safety con-
tacts / safety edges
Garage light output
10- INPUTS 21- EMERGENCY STOP
Encoder input Emergency stop input
11- INPUTS 22- 12/24Vdc SELECTOR
Connection for inputs, limit switches or safety con-
tacts / safety edges
12Vdc or 24Vdc selector
jcmtechnologies
5

Indication LEDs
LED ON GREEN Led indicates control panel power supply
LED PROG RED Led indicates programming activation
LEDs INPUTS RED Leds indicate input activation
LEDs OUTPUTS GREEN Leds indicate output activation
LEDs MOTOR YELLOW Leds indicate activation of the motor movement button and direction
If Leds flash, they indicate slow speed
LED ERROR RED Led indicates errors (see "Troubleshooting")
jcmtechnologies
6

Installation
Install the control panel vertically on the wall at a height of 1.5m and following the assembly instructions.
Connections
POWERSUPPLYANDMOTORCONNECTIONS OUTPUTS
INPUTS
jcmtechnologies
7

PHOTOCELLCONNECTIONWITHAUTOTEST
ABSOLUTEENCODERCONNECTION
jcmtechnologies
8

Configuration
Options selector
By default all selectors leave the factory set to OFF.
OFF OPTIONSSELECTOR ON
Do not closes automatically 1- AUTOCLOSE Closes automatically
Normal speed in all the manoeuvre 2- SLOW SPEED Slow speed available at the end of
the manoeuvre
Enables the operation by end limit
switches 3- ABSENCODER/LIMITSW Enables the operation by ABS
encoder
Normal opening 4- REVERSE STRIKE Performs a reverse strike 2s before
opening the door
The safety contact performs its
formal function 5- CLOSE BY CSEG
The safety contact operates as a
close button once the vehicle has
passed
One motor (M1) operating 6- TWO MOTORS MODE Both motors operating (M1 and M2)
OFF OPTIONSSELECTOR ON
Start button performs an stop at
opening 7- NO REVERSE AT OPEN Start button opens until total open-
ing
The electrolock is activated 2s
before opening the door + 1s during
the opening
8- ELECTROLOCK The elctrolock is disabled
Test safety contact in opening dis-
abled 9- TEST CSEG OPEN Test safety contact in opening
enabled
Test safety contact in closing dis-
abled 10- TEST CSEG CLOSE Test safety contact in closing
enabled
Adds 3s after inversion in closing 11- ELECTROMEC/HYDR Do not adds time after inversion in
closing
Pushbutton in IN7 performs a start
button 12- OPEN/START Pushbutton in IN7 performs an
open button
jcmtechnologies
9

Starting up
Door Positioning
1PRESS PROGBUTTON 2PRESS MOTOR2 CLOSETO
CLOSEIN DM 3DOOR 2 CLOSES 4PRESS MOTOR1 CLOSETO
CLOSEIN DM
5DOOR 1 CLOSES 6PRESSPROGBUTTON 7LED TURNS OFF 8END DOOR POSITIONING
Considerations:
In step 2, if MOTOR2 CLOSEis pressed and the door opens, reverse themotor 2 wires, and return to step 1.
In step 4, if MOTOR1 CLOSEis pressed and the door opens, reverse themotor 1 wires, and return to step 1.
jcmtechnologies
10
Indice
Altri manuali JCM Technologies Pannello di controllo

JCM Technologies
JCM Technologies EASY-ROLL Manuale utente

JCM Technologies
JCM Technologies F30 Manuale utente

JCM Technologies
JCM Technologies BASIC-PLUS Manuale utente

JCM Technologies
JCM Technologies KEEROLL Manuale utente

JCM Technologies
JCM Technologies ROLL868 DMR Manuale utente

JCM Technologies
JCM Technologies INTEGRA Manuale utente

JCM Technologies
JCM Technologies M8 Manuale utente

JCM Technologies
JCM Technologies KEEROLL Manuale utente