Jung TK IS A 514 A Series Manuale utente

Product Information
DCM Standard indoor stations
TK IS A 514 A ..
TK IS A 514 AD .. (Design)
ALBRECHT JUNG GMBH & CO. KG
Volmestraße 1
58579 Schalksmühle
Phone +49.2355.806-0
Fax +49.2355.806-189
Internet: gb.jung.de

2
Table of content
Information about this manual ............................................................................................... 3
Safety instructions ................................................................................................................. 3
Application / Brief description ................................................................................................ 4
Application ......................................................................................................................... 4
Brief description................................................................................................................. 4
Device overview .................................................................................................................... 5
Indication and operation ........................................................................................................5
Wiring and installation ........................................................................................................... 6
Wiring example..................................................................................................................6
Connecting diagram........................................................................................................... 7
Slide switch........................................................................................................................ 7
Installation of bottom shell ................................................................................................. 8
Connecting wires ............................................................................................................... 8
Adjust the device for 2- or 3-wire operation ....................................................................... 9
Assembling device............................................................................................................. 9
Opening the device...........................................................................................................10
Commissioning.....................................................................................................................11
Device settings.....................................................................................................................11
Storing the device settings................................................................................................11
Factory settings ................................................................................................................11
Function button ....................................................................................................................12
Setting of function button:
Internal call, call diversion, door release function and control function .............................12
Light switching ..................................................................................................................15
Reloading the factory settings ..........................................................................................15
Adjusting the function button with the service device........................................................16
Ring tone selection...............................................................................................................17
Ring tone volume / Ring tone OFF/ON .............................................................................17
Ring tone selection for:
Outdoor station 1, Outdoor station 2, Internal call, Floor bell button .................................18
Operation .............................................................................................................................24
Start communication, door release, switching light ...........................................................24
Explanation of terms and definitions.....................................................................................27
General notes on the wiring in DCM audio systems.............................................................29
Technical data......................................................................................................................30
Cleaning ...............................................................................................................................30
Acceptance of guarantee .....................................................................................................31

3
Information about this manual
On pages 27 and 28 you can read the "terms and definitions" of this manual.
We recommend to read these explanation carefully before you start the adjustment of
the indoor station.
Safety instructions
!Assembly, installation, and commissioning must only be carried out by a qualified
electrician!
For work on systems with 230 V AC mains current the safety requirements of DIN VDE 0100
must be observed.
When installing DCM BUS systems the general safety rules for telecommunication systems
in accordance with VDE 0800 must be observed:
•separate cabling for high and low voltage lines
•minimum distance of 10 cm for joint cabling arrangements,
•use of separators between high and low voltage lines in joint cable ducts,
•use of standard telecommunication cables, e. g. J-Y (St) Y with 0.8 mm² cross section
!Suitable lightning prediction must ensure that a voltage of 32 V DC will not be
exceeded at the DCM BUS wires a and b.
DCM = Door Communication Management

4
Application / Brief description
Application
•acoustical and optical indication of front door and internal calls
•hands-free operation with high audio quality
•door release function
•switching light
•The standard design version enables the installation of frames of the design ranges
AS 500, A 500, Aplus and A creation.
Brief description
•hands-free operation , manually controlled simplex communication can be activated
•internal call with automatically hands-free operation
•door release button
•function button switches lighting (Basic settings)
Alternative assignment: Control function, internal call, automatic door release, call
diversion
•Push-button for taking call or change over between speaking/listening if simplex
communication is activated
•Selection of 13 ring tones
•ring tone differentiation between main door, floor door and internal call
•sub door call: 4 bell buttons of the outdoor station can be assigned to 4 different ring
tones of the indoor station
•ring tone differentiation of 2 outdoor stations
•ring tone volume manually adjustable
•high quality sound and great speaker dynamic
•ring tone mute with optical display
•1 parallel call can be activated
•integrated connection for floor door bell
•optical short-term memory of door calls
•audio privacy function
•automatic call cut-off
•optical status indication if system is occupied (existing communication)
•2- and 3-wire technique
•blue orientation LED (3-wire technique required)
•electret capacitor microphone
•audio- and video indoor stations can be combined in the same installation

5
Device overview
Indication and operation
Ring tone button •Adjustment of ring tone volume
•Initiate setting mode for ring tones
Indication LED on = Ring tone deactivated
Communication
button •Start/end of hands free communication
•Switching and operating the simplex communication
Indication
LED flashes: incoming door call / communication occupied
LED off: no communication
LED on: talking mode
Function
button •Activation of the assigned function
•Initiate the setting mode of the function button
Indication LED on = Call diversion or automatic door release is activated
Door release
button •Activation of door release
(and light, if light switch function is activated)
Indication LED on: for approx. 3 s when door release is activated
Light strip •Blue illuminated vertical light strip
Indication illuminated, if P-wire is connected and slide switch adjusted for
3-wire operation
Li
g
ht stri
p
Ring tone button
Door release button
Communication
button
Function
button
Micro
p
hone
Louds
p
eaker
LEDs

6
Wiring and installation
Wiring example
2-wire technique
Please observe cable length and loop resistance.
No illumination of indoor station in 2 wire installations
possible. Slide switch in position II.
Floor bell button
Floor bell button
Indoor station
Indoor station
Outdoor station
Power supply &
control unit
Door release
relay and
illumination

7
Connecting diagram
2-wire operation
3- wire operation
Slide switch
2- wire operation
3- wire operation
3-wire technique
Please observe cable length and loop resistance.
Slide switch in position III.
Floor bell button
Floor bell button
Indoor station
Indoor station
Outdoor station
Power supply &
control unit
Door release
relay and
illumination

8
Installation of bottom shell
•Recommended installation height: 1.5 m
•For an easier installation and space for the
wires a flush box for wall mounted lamps is
recommended (see. figure below).
•Place the cable entry over the flush box.
•Connect the bottom shell with adequate
screws. Consider the TOP site as shown in
the image!
Therefore you can use the connection holes
(1) and (2) for direct fixing on the wall.
The connection holes (1) can be used to
connect an indoor station with design frame
onto a wall box with hole centre distance of
60 mm.
Connecting wires
Type of cable:
Telecommunication cable J-Y (St) Y with
twisted pairs with a cross section of 0.6 mm
or 0.8 mm.
•Take off the connection block (3).
•Attach the wires to the connection block in
accordance with the terminal description on
the bottom shell (A B E P).
•Place the wires into the guide slot to avoid,
that the wires do not get pinched or
damaged.
•Plug on the connection block in the original
position.
Bottom shell
Flush box for wall mounted lamps
2
2
1
1
3
4
4

9
Adjust the device for 2- or 3-wire
operation
•2-wire operation:
Factory settings: The slide switch is in
position II.
The a and b wire will be connected.
•3- wire operation:
Putt he slide switch in position III
The a, b and P wire will be connected.
Top device (reverse side)
2-wire operation
3- wire operation
Assembling device
Device without design frame (A)
•Put the top device onto the snap
connectors (4) of the bottom shell and
press until you can here a snap-on
sound.
Device with design frame (B)
•Put the design frame onto supporting
frame of the bottom shell.
•Put the top device onto the snap
connectors (4) of the bottom shell and
press until you can here a snap-on
sound.
A
B
Design
frame
4
Combi
label
Slide switch
4
Supporting
frame

10
Opening the device
1. On the bottom side of the indoor station
is a squared slot to unlock and open the
device. Insert a screwdriver (approx.
7mm) with slight pressure straight into
the slot.
2. The device can be pulled at the lower
side out of the shell (1).
3. Remove the top shell from the snap
connector (2).
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Jung Sistema di interfono