K2 UTM01602K Manuale utente

OWNER’S MANUAL
NON-AUTOMATIC UTILITY PUMP
Questions, problems, missing parts? Before returning to the store call K2 Customer
Service 8 a.m. - 6 p.m., EST, Monday-Friday
1-844-242-2475 © 2019 Copyright GP Enterprises Co., Ltd.
Rev. 11/06/19
Model: UTM01602K
UTM02502K

2 For Professional Technical Support call 1-844-242-2475
PERFORMANCE
Model
HP
GPH of Water @ Total Feet Of Lift
Max. Lift
0 ft.
5 ft.
10 ft.
15 ft.
20 ft.
25 ft.
UTM01602K
1/6
1500
1400
1300
1100
750
300
27 ft.
UTM02502K
1/3
2200
2000
1750
1500
1200
800
31 ft.
SAFETY INSTRUCTIONS
1. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion
or fire, resulting in property damage, serious personal injury, and/or death.
2. ALWAYS disconnect the power to the pump before servicing.
3. Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4. Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water
before disconnect the power.
5. Release all pressure and drain all water from the system before servicing any component.
6. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury, and/or property damage.
7. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening
safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension
cord to power this pump is not permitted.
8. Wear safety goggles at all times when working with pumps.
9. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor
cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must
be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this
pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI
outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should
be performed by a qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO
USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 10 Amp fuse or circuit breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.
15. Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping
the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature
failure.
16. Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and
debris. Disconnect the pump from the power supply before inspecting.
17. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all
Occupational Safety and Health Administration (OSHA) guidelines must be followed.
18. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset
itself once the motor cools down and an acceptable temperature has been reached. The pump may start
unexpectedly if it is plugged in.
19. Ensure the electrical power source is adequate for the requirements of the pump.

For Professional Technical Support call 1-844-242-2475 3
20. Before using the pump, check the hose for holes or excess wear, which could cause leaks, and ensure the hose is
not kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of water quickly,
and also check that all hose connections are tight to minimize leaks.
21. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time
when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris
may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump
problems and remedies.
PRE-INSTALLATION
APPLICATION
This submersible utility pump is designed for water removal applications. Pump water only with this pump. It can
drain or remove water from the following: pits, sinks, window wells, basements, swimming pool covers, boats, low
spot in yards, or other flooded areas.
This pump has not been tested or approved for use in swimming pools or in salt-water marine areas. This pump is
not designed to function as a permanently installed sump pump. It is also not engineered to be run continuously as
a “fountain” or “waterfall” pump.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.
Function:
Operating water depth: minimum 1 in.
TOOLS REQUIRED
MATERIALS REQUIRED (NOT INCLUDED)
NOTE:The hose and hose kit are not shown to scale.
SPECIFICATIONS
Power supply
115V, 60 HZ., 10 Amp Circuitminimum
Liquid Temp. Range
32 to 95°F (0- 35°C)
Discharge
1 in. Male NPT or 3/4 in. garden hose thread
Phillips
Screwdriver
Flathead
Screwdriver
Wrench
Safety
Goggles
Garden
Hose
Sump
Pump
Discharge
Hose Kit

4 For Professional Technical Support call 1-844-242-2475
INSTALLATION
CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns,
unplug the pump and allow time for it to cool after periods of extended use.
1. Connecting a 3/4 in. garden hose
Attach a 1 in. female adaptor (B) to the pump discharge.
Attach a garden hose with a 3/4 in. garden hose thread (not included) to the adaptor.
NOTE: Be sure the 3/4 in. garden hose thread connector has a rubber gasket to
minimize water leaks.
NOTE: The larger the inside diameter and the shorter the length of hose, the less
pressure that is lost (or the larger the flow rate).
2. Connecting a 1-1/4 in. hose kit
If you would prefer to use a 1-1/4 in. hose kit (not included) in order to pump water away
more quickly.
Attach the adaptor (B) to the pump (A) discharge.
Securely attach the hose kit (not included) to the adaptor (B).
WARNING: Secure the discharge hose before plugging in the pump. An unsecured
discharge hose may “whip” possibly causing personal injury, and/or property damage.
OPERATION
1. Plugging in the pump
Place the pump on a solid base in flooded area or any place that you
would like to remove water. Plug the pump into a 115 volt GFCI power
outlet
WARNING: Do not handle the pump or pump motor with wet hands or when
standing on a wet or damp surface, or in water.
NOTE: Place upright on a solid base.
NOTE: The pump must be standing in at least 1 in. (25.4 mm) of water before
you start it.
2. Operating the pump
Allow the pump to run and monitor its progress.
Unplug the pump when it has removed water down to
approximately 1/ 4in. (6.4 mm).
Remove the pump and hose from the location when finished
pumping. The hose still has water that can drain back through the
pump. Remove remaining water with a squeegee, mop, sponge,
towel, wet/dry vacuum, etc.
CAUTION: Do not run the pump dry. Operating the pump without water will cause damage to the seals and will cause
the pump to fail, thereby voiding the pump’s warranty.

For Professional Technical Support call 1-844-242-2475 5
NOTE:After starting, the pump will lower the water level to 1/ 4in. (6.4 mm) before losing suction. It will not pick up water
less than1/ 4in. (6.4 mm)deep when running and will not operate successfully if started in only 1/ 4in. (6.4 mm)of water.
AIRLOCK
This pump is a centrifugal utility pump, designed to efficiently remove water.
However, it cannot move air. If airis trapped inside the pump (a condition
called“airlock”), the pump cannot pump water out even thoughthe pump is
completely submerged. This pump has an anti-airlock hole. Air flows out
through the anti-airlock hole, eliminating the airlock so that the pump can operate
properly. If debris blocks the anti-airlock hole, unplug the pump, clean out the
anti-airlock hole, and restart thepump. Alternately, drain the water out of the
garden hose, keep the end of the hose out of the water, and plugin the power
cord, restarting the pump.
CAUTION: This hole is for anti-airlock purposes. Leakage of air or water is
NORMAL.
DO NOT BLOCK THIS HOLE!
CARE AND CLEANING
CAUTION:Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug
the pump and allow time for it to cool after periods of extended use.
Do
Do Not
When the power is disconnected, inspect the pump
suction screen and remove all debris, then plug the
pump back into the grounded (GFCI) outlet.
Do not disassemble the motor housing. This motor has
NO repairable internal parts, and disassembly may
cause leakage or dangerous electrical wiring issues.
Do not lift up the pump by the power cord.
To clean a pump clogged with debris:
Unplug the pump from electrical power.
Unscrew the stainless screws(7), and remove the bottom
plate(6)
Unscrew the stainless screws(5), and remove the volute(4)and
gasket(3)
Use a flathead screwdriver to hold the shaft (1), then turn the
impeller (2) counterclockwise to release the impeller (2).
Remove debris from around the shaft (1) and on/under the
impeller (2).
Reassemble.

6 For Professional Technical Support call 1-844-242-2475
TROUBLESHOOTING
Problem
Possible Cause
Corrective Action
Pump does not start or run
1. The fuse is blown.
2. The breaker is tripped.
3. The plug is disconnected.
4. The plug is corroded.
5. The motor failed.
6. Ice or blockage has locked the
impeller.
1. Replace the fuse.
2. Reset the breaker.
3. Secure the plug.
4. Clean the plug prongs.
5. Replace the pump.
6. Remove the blockage.
Pump cannot pump water out
1. The screen is blocked.
2. The hose is kinked, bent sharply, or
coiled.
3. There is airlock.
4. The hose length is too long.
5. The impeller is loose on the shaft.
6. The impeller is broken.
1. Clean the screen.
2. Straighten the hose.
3. Clean the anti-air lock hole.
4. Use a shorter hose.
5. Reassemble the impeller.
6. Replace the impeller.
WARRANTY
Limited Warranty
WHAT THIS WARRANTY COVERS
When used and maintained in normal use and in accordance with the Owner’s Manual, your K2 product is warranted
against original defects in material and workmanship for at least one year (warranty varies depending on model; see box
for specific warranty information) from the date of purchase (the “Warranty Period”). During the Warranty Period, K2 will
repair or replace at no cost to you, to correct any such defect in products founds upon examination by K2 to be defective
in materials or workmanship.
Your dated receipt of purchase is required to make a warranty claim.
WHAT THIS WARRANTY DOES NOT COVER
This Warranty does not cover:
Use of the product in a non-residential application, improper installation and/or maintenance of the product, damage due
to misuse, acts of God, nature vandalism or other acts beyond control of K2, owner’s acts or omissions, use outside the
country in which the product was initially purchased and resale of the product by the original owner. This warranty does
not cover pick up, delivery, transportation or house calls. However, if you mail your product to an K2 Sales and Service
Center for warranty service, cost of shipping will be paid one way. This warranty does not apply to products purchased
outside of the United States, including its territories and possessions, outside of U.S. Military Exchange and outside of
Canada. This warranty does not cover products purchased from a party that is not an authorized retailer, dealer or
distributor of K2 products.
OTHER IMPORTANT TERMS
This warranty is not transferable and may not be assigned. This Warranty shall be governed and construed under laws
of the state of Michigan. The Warranty Period will not be extended by any replacement or repair performed under this
Warranty. THIS WARRANTY IS THE EXCLUSIVE WARRANTY AND REMEDY PROVIDED BY K2. ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OR MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE, ARE DISCLAIMED. IN NO EVENT WILL AQUAPRO BE LIABLE FOR ANY SPECIAL,
INDRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND OR NATURE TO OWNER OR ANY
PARTY CLAIMING THROUGH OWNER WHETHER BASED IN CONTRACT, NEGLIGENCE, TORT, OR STRICT
PRODUCTS LIABLITY OR ARISING FROM ANY CAUSE WHATSOEVER. Some states do not allow for the exclusion

For Professional Technical Support call 1-844-242-2475 7
of consequential damages, so the above exclusion may not apply to you. This warranty gives you specific rights. You
may also have others that vary from state to state.
Thank you for choosing an K2 product!
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali K2 Pompa dell'acqua
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente