Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615
C SERIES UPS
50 - 300 kVA 1.0 PF 208 Vac 3Ph
Users Guide
UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER
(A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER
INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION;
(B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL,
DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION.
THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK; AND
(C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN
TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED
CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE.
(D) INFORMS YOU THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE.
(E) RESERVES ALL RIGHTS.

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 1
Contents
1.Safety...................................................................................................................................................... 2
1.1 Safety notes .................................................................................................................................. 2
1.2 Symbols used in this guide........................................................................................................ 2
2.Main Features ....................................................................................................................................... 3
2.1 Summary ........................................................................................................................................ 3
3.Installation ............................................................................................................................................. 4
3.1 Unpacking ..................................................................................................................................... 4
3.2 The appearance of the product ................................................................................................. 4
3.4 Installation notes ........................................................................................................................ 12
3.5 External Protective Devices ..................................................................................................... 13
3.6 Power Cables .............................................................................................................................. 13
3.7 Power cable connect ................................................................................................................. 17
3.8 Battery connection .................................................................................................................... 18
3.9 UPS Parallel Installation ............................................................................................................ 19
3.10 LBS installation ........................................................................................................................ 21
4.Operation ............................................................................................................................................. 22
4.1 Operation Modes ........................................................................................................................ 22
4.2 Turn on/off UPS .......................................................................................................................... 24
4.3 Touch Screen LCD Display ...................................................................................................... 28
4.4 Fault and Alarm Information .................................................................................................... 59
4.5 Options......................................................................................................................................... 62
Appendix 1 Specifications ..................................................................................................................... 63
Appendix 2 Problems and Solution ...................................................................................................... 67
Appendix 3 CAN communication port definition ............................................................................... 69
Appendix 4 RS485 communication port definition ............................................................................ 70
Appendix 5 COM communication port definition .............................................................................. 71
Appendix 6 LBS Port Definition ............................................................................................................ 72
Appendix 7 REPO instruction ................................................................................................................ 73

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 2
1.Safety
Important safety instructions - Save these instructions
This UPS contains lethal voltages and high temperature inside. All repairs and service should be
performed by AUTHORIZED AND QUALIFIED PERSONNEL ONLY. There are NO USER
SERVICEABLE PARTS inside the UPS. To reduce the risk of personal injury and equipment
damage, abide by all local safety codes and laws during operation, installation and maintenance.
Safety instructions in this manual act as a supplement to local safety codes and laws. Our company
does not assume any liability or responsibility caused by disobeying local safety codes and laws.
1.1 Safety notes
1. The UPS is attached to an energy source (batteries).
2. The UPS output may carry live voltage even when the UPS is not connected to an AC
supply.
3. To reduce the risk of electric shock, securely ground the UPS.
4. Batteries can present a risk of electrical shock or burn from high short-circuit current.
Observe proper precautions.
5. Only qualified service personnel with knowledge of batteries and the required precautions
should perform servicing.
6. Keep unauthorized personnel away from batteries.
7. Proper disposal of batteries is required. Refer to your local codes for disposal
requirements.
8. Never dispose of batteries in a fire. Batteries may explode when exposed to flame.
9. To reduce the risk of fire or electric shock, install the UPS in a temperature and humidity
controlled, indoor environment, free of conductive contaminants (flammable gas,
excessive dust, etc.).
10. Ambient temperature must not exceed 40°C (104°F).
11. Do not operate near water or in excessive humidity (95% maximum).
12. To reduce the risk of overheating and fire, operate the UPS in a well-ventilated area.
13. Output overcurrent protection and disconnect switch must be provided by others.
1.2 Symbols used in this guide
WARNING!
RISK OF ELECTRIC SHOCK
CAUTION!
Read this information to avoid equipment damage

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 3
2.Main Features
2.1 Summary
This UPS is a threephase in threephase out high frequency online UPS. The UPS helps avoid
power supply problems, such as blackout, over-voltage, under-voltage, sudden voltage drop, high
voltage pulse, voltage fluctuation, surge, inrush current, harmonic distortion (THD), noise
interference, frequency fluctuation, etc.
This UPS can be applied to different applications including computer device, automatic equipment,
communication system and industry equipment.
2.2 Functions and Features
◆3 Phase In / 3 Phase Out high-density UPS system.
◆Digital Control - This UPS is controlled by Digital Signal Processor (DSP)
◆Charging Current is configurable - Via setting tool, the user may set the capacity of the batteries
and charging current as well as maximum charging current. Constant voltage mode, constant
current mode or floating mode can be switched automatically and smoothly.
◆Intelligent Charging Method
The series UPS adopts advanced three-stage charging method
1st stage: high current constant current charging to charge back to 90%
2nd-stage: Constant Voltage
3rd stage: floating mode
◆Large Touch Screan LCD Display of UPS status and operational parameters, such as:
input/output voltage, frequency & load%, battery % and ambient temperature, etc.
◆Intelligent Monitoring Function - Via optional SNMP Card, remotely control and monitor the
UPS.
◆Equip with Maintenance Bypass Switch for easy maintenance purpose.
◆EPO Function - The UPS may be completely shut off when the EPO is pressed. REPO function
(Remote EPO) is also available.

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 4
3.Installation
3.1 Unpacking
If any equipment received has been damaged during shipment, keep the shipping cartons and
packing materials for the carrier or place of purchase and file a claim for shipping damage. If you
discover damage after acceptance, file a claim for concealed damage.
To file a claim for shipping damage or concealed damage: 1) File with the carrier within 15 days of
receipt of the equipment; 2) Send a copy of the damage claim within 15 days to your service
representative.
3.2 The appearance of the product
50kVA&60kVA&80kVA (Full configuration), bottom entry
Front View Side View Rear View
Front View (internal) Front View (Copper bar)
C Series 100kVA&120kVA (Full configuration), bottom entry

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 5
Front View Side View Rear View
100kVA&120kVA (Full configuration), bottom entry
C Series 160/200kVA(Full configuration), top and bottom entry

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 6
Front View (internal) Rear View (internal)
Full configuration, top entry

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 7
Full configuration, bottom entry
Front View (internal) Rear View (internal)
250kVA&300kVA (Standard and Full configuration), top and bottom entry
Front View Side View Rear View

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 8
250kVA(Standard and Full configuration), top and bottom entry
Standard configuration Full configuration
Connect coppper bar Mains-bypass common copper bar

Keatec C Series UPS 50 - 300 kVA 1.0 PF 208 Vac 3Ph Users Guide English 20190615 Page 9
300kVA (Standard and Full configuration), top and bottom entry
Standard configuration Connect copper bar
Connect coppper bar Mains-bypass common copper bar
Indice
Altri manuali Keatec Energy UPS

Keatec Energy
Keatec Energy T SERIES Manuale utente

Keatec Energy
Keatec Energy RTM Series Manuale utente

Keatec Energy
Keatec Energy RT 6KVA Manuale utente

Keatec Energy
Keatec Energy DBL MX-U Series Manuale utente

Keatec Energy
Keatec Energy RTM Series Manuale utente

Keatec Energy
Keatec Energy T SERIES Manuale utente

Keatec Energy
Keatec Energy T 3310E Manuale utente
Manuali UPS popolari di altre marche

Pylontech
Pylontech Victron & Pylontech US5000 Manuale utente

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuale utente

Mecer
Mecer ME-1000-WTU Manuale utente

Mustek
Mustek PowerMust 530(B) Plus Manuale di installazione e funzionamento

Emerson
Emerson Liebert NXL series Manuale utente

MAKELSAN
MAKELSAN BOXER SERIES Manuale utente