With tool open, hold one handle while placing the
other handle on a scale. Monitor the downward pres-
sure required to close handles. Properly adjusted tool
will require 10-15lbs of pressure.
If adjustment is required twist locking screw counter-
clockwise to loosen. Rotate adjustment screw clockwise
to increase, counterclockwise to decrease pressure.
Aer correct pressure is established, tighten locking
screw. Use 4mm hex key. All tools are inspected and
properly adjusted prior to shipment.
Maintenance Tips
Maintain optimum crimp strength:
Warranty:
One year warranty covers only defects in
materials and workmanship. Regularly oil all
pins and joints. Always wear eye protection.