You only need a few minutes to get started withthe
@Znh^\]i 81133A and 81134A Pulse Generator.
This Getting Started Brochure helps you to quickly
understand the operating principles and
set up your first signals.
If you need more detailed information on the
@Znh^\]i 8133A and 81134A Pulse
Generator,check out the Online Help.
Getting Started
with the
@Znh^\]i Pulse Generator
81133A/81134A
F
or
mo
re
ex
a
mp
les
a
nd
re
mo
te
pro
gr
am
m
ing
in
fo
rm
ati
on
,
d
el
iv
ere
d
on
t
he
pr
od
uc
t
CD
.
p
le
as
er
efe
rt
o
th
eU
se
r
Gu
ide
a
nd
th
e
Pro
gr
am
m
in
g
Gu
id
e,

Notice
2
Safety Summary
Copyright
© @Znh^\]i Technologies, Inc. 2019
:Y^i^dc
:Y^i^dc 4.0, April '%19
Printed in Germany
@Znh^\]i Technologies, Deutschland
GmbHHerrenberger Str. 130
71034 Boeblingen, Germany
Technology Licenses
The hardware and/or software described in this
document are furnished under a license and may
be used or copied only in accordance with the
terms of such license.
Warranty
The material contained in this document is provided
“as is,” and is subject to being changed, without
notice, in future editions. Further, to the maximum
extent permitted by applicable law, @Znh^\]i disclaimsall
warranties, either express or implied, with regardto this
manual and any information contained herein,including but
not limited to the implied warranties ofmerchantability and
fitness for a particular purpose. @Znh^\]i shall not be liable
for errors or for incidental
or consequential damages in connection with the
furnishing, use or performance of this document or of
any information contained herein. Should @Znh^\]i and
the user have a separate written agreement with
warranty terms covering the material in this document
that conflict with these terms, the warranty terms in
the separate agreement shall control.
Restricted Rights Legend
If software is for use in the performance of a
U.S. Government prime contract or subcontract,
Software is delivered and licensed as “Commercial
computer software” as defined in DFAR 252.227-7014
(June 1995), or as a “commercial item” as defined
in FAR 2.101(a) or as “Restricted computer software”
as defined in FAR 52.227-19 (June 1987) or any
equivalent agency regulation or contract clause. Use,
duplication or disclosure of Software is subject to
@Znh^\]i Technologies’ standard commercial license
terms, and non-DOD Departments and Agencies ofthe
U.S. Government will receive no greater thanRestricted
Rights as defined in FAR 52.227-19(c)(1-2)(June 1987).
U.S. Government users will receive nogreater than
Limited Rights as defined in FAR 52.227-14(June 1987)
or DFAR 252.227-7015 (b)(2) (November1995), as
applicable in any technical data.
]iie/$$lll#`Znh^\]i#Xdb$[^cY$Vhh^hi
Services and Support
Any adjustment, maintenance, or repair of this
product must be performed by qualified personnel.
Contact your customer engineer through your local
@Znh^\]i Technologies Service Center. You can find
a list of local service representatives on the Web at: Do Not Remove the Instrument Cover
Operating personnel must not remove instrument
covers. Component replacement and internal
adjustments must be made only by qualified
personnel.
Instruments that appear damaged or defective
should be made inoperative and secured against
unintended operation until they can be repaired by
qualified service personnel.
General Safety Precautions
The following general safety precautions must be
observed during all phases of operation of this
instrument. Failure to comply with these precautions
or with specific warnings elsewhere in this manual
violates safety standards of design, manufacture,
and intended use of the instrument.
@Znh^\]i Technologies Inc. assumes no liability
forthe customer's failure to comply with these
requirements.
Before operation, review the instrument and manual
for safety markings and instructions. You must
follow these to ensure safe operation and to
maintain the instrument in safe condition.
General
This product is a Safety Class 1 instrument
(provided with a protective earth terminal).The
protective features of this product may be
impaired if it is used in a manner not specified in
the operation instructions.
All Light Emitting Diodes (LEDs) used in this
product are Class 1 LEDs as per IEC 60825-1.
This instrument is intended for indoor use in an
installation category II, pollution degree
2 environment. It is designed to operate at a
maximum relative humidity of 95% and at altitudes
of up to 2000 meters.
Refer to the specifications tables for the ac mains
voltage requirements and ambient operating
temperature range.
Environmental Conditions
Before Applying Power
Verify that all safety precautions are taken.
The power cable inlet of the instrument
serves as a device to disconnect fromthe
mains in case of hazard.
The instrument must be positioned so that
the operator can easily access the power
cable inlet. When the instrument is rack-
mounted the rack must be provided with
an easily accessible mains switch.
General operation advises the mains supply
voltage fluctuations are not to exceed 10%
of nominal supply voltage
To minimize shock hazard, the instrument chassis
and cover must be connected to an electrical
protective earth ground. The instrument must be
connected to the ac power mains through a
grounded power cable, with the ground wire firmly
connected to an electrical ground (safety ground)
at the power outlet. Any interruption of the
protective (grounding) conductor or disconnection
of the protective earth terminal will cause a
potential shock hazard that could result in
personal injury.
Ground the Instrument
Do Not Operate in an Explosive Atmosphere
Do not operate the instrument in the presence of
flammable gases or fumes.

Installing the @Znh^\]i 81133A and 81134A
Check if the @Znh^\]i 81133A or 81134A shipping
containercontains the following standard deliverables:
If the contents are incomplete, if there is mechanical damage, or if the
instrument does not work within its specifications, notify the nearest
@Znh^\]i office. The @Znh^\]i office will arrange for repair or
replacementwithout awaiting settlement.
Once you have plugged in the instrument, you can start using it.
Make sure you keep the ventilation holes free wherever you install
the instrument.
The USB interface will be supported starting spring 2003.
Please visit our Web page for a free update of the firmware.
Please refer to the User Guide delivered on the
Product CD if you need more information about
working with the instrument.
`Znh^\]i
e Genarator
The @Znh^\]i Pulse Generator
81133A or 81134A
This Getting Started Brochure
power cable
The Product CDs
3
USB cable

Getting Started with the @Znh^\]i 81133A and 81134A
Now that you have unpacked the instrument and plugged it in,
let´s take a look at the main elements of the front panel.
Switch on the instrument. You can immediately start playing with the settings.
Start by pressing the tab keys. You see that only the lower part of the panel page
changes. You can switch between five panel pages, which allow you to set
parameters for different instrument settings.
The parameters at the upper part of the panel page are valid for the whole instrument.
4
Main Page
Channel Page
Data Page Aux Page
Navigate through the pages with the Tab Keys
Tab Keys to navigate
between the pages
Navigation knob
Softkeys Numeric Keys
Channel-specific
inputs and outputs
Global inputs
andoutputs
Config Page

Changing Parameters
The navigation knob makes it easy to move through
and set the parameters.
Rotate the navigation knob
to move from one parameter
to the next.
Let’s select a parameter
from a selection list.
Press the navigation knob
to open the selection list
(like clicking
with the mouse).
Rotate the navigation knob
to scroll through the list.
Select an item by pressing
the navigation knob.
You have three options for using the navigation knob.
rotate press and rotatepress 5

Changing Parameters
Now let´s change a number field
Press the navigation knob
once to focus at the
number field.
Turn the navigation knob
to set the number
Release the navigation knob.
Now when you rotate it,
the number changes.
Press the navigation knob
once when you are done.
You can also:
6
When you rotate the navigation knob
the value changes. You can do this in run time.
It let’s you immediately see the changes on a scope.
Press the navigation knob
once when you are done.
Press and rotate the
navigation knob to
select the digit.You can also press the
arrows next to the navigation knob.
Use the arrows next the
navigation knob
to select a digit.
Enter a value
with the key pad.
Or, to change one digit

Setting Up a Data Pattern
Imagine, you have designed a new digital circuit with ECL logic and
3.3 GHz clock, and you want to check its correct behavior.
To test it, you decide to simulate a 32-bit pattern signal with NRZ
data output format:
7
11110011100110010010100100000000
Now let’s set the instrument parameters
Whenever you change a parameter, the generated signal immediately changes.
To protect your DUT, make sure you disconnect the channel outputs first.
Do this by pressing the softkey next the following function:
Protect the DUT
The open contactor shows you
that your DUT is now disconnected
First, disconnect the outputs
to protect the DUT
Select the Unit
Choose the Pulse/Pattern Mode
for the Signal
These define the signal that will be generated.
Enter the Frequency value
using the keypad
3
2
1
4

Setting Up a Data Pattern
8
You can now set the channel mode, timing and
level parameters for the channel
Switch to the Channel Page
Select Pulse Mode Data
Select Pulse Type NRZ
Select the ECL level format
Indicates that the Parameters
are set for Channel 1
You can switch
between the two channels
by pressing this softkey
1
2
3
4
The LEDs show the status
of the outputs
gray = disabled, green = enabled,
crossed out = all outputs disconnected
Enable the Channel 1 normal Output
by pressing the respective softkey
5
5
Now let’s set the data
Switch to the Data Page
Switch to the Numeric Edit Mode
Enter a data pattern
length of 32 bits
Enter your data pattern
1
4