Keystone SOLARFLEX 600i-L Manuale utente

BEFORE STARTING:
• Verify proper system set up from SF 600i-L Quick Start Guide at www.keystonerv.com
• Is the 12 Volt Battery Disconnect for the unit turned on? Found near entry door on interior wall or in
exterior front storage compartments.
• Is the solar panel, clean, in direct sunlight, free from obstructions/debris?
»Clean with water and a cloth/sponge
THE VICTRON APP DOES NOT RESPOND ON MY SMART DEVICE:
• Bluetooth is off
»Turn on Bluetooth, close and restart app
• Outside Bluetooth range of the solar controller
»Move within a few feet of the solar controller
I AM UNABLE TO SELECT THE CONTROLLER OR THE
SHUNT FROM THE DEVICE LIST ON MY SMART DEVICE
(NOT ACTIVE OR HIGHLIGHTED):
Another device is already connected to the APP and only one device can
be connected at a time
APP INDICATES AN UPDATE TO FIRMWARE IS NEEDED:
• Allow the update
SMART SOLAR WATTS, VOLTAGE AND CURRENT ALL
READ “0” ON THE VICTRON CONNECT APP:
• No power to Charge controller (found in front compartment or pass through)
»Verify the 10 gauge (+) and (–) wires from the solar panel are tight and properly connected to the
(+) and (–) connections labeled “PV”
• Solar Panel not connected to the roof port
»Connect the Solar Panel to the roof port
In partnership with
SOLARFLEX 600i-L BASIC
TROUBLESHOOTING GUIDE
VICTRON COECT APP
USER MANUAL
IF BATTERY VOLTAGE READS
“0” VOLTS, CHECK FOR POOR
COECTION TO BATTERY.

PASSWORD DOES NOT ALLOW ACCESS TO VICTRON APP:
• Log in with factory Default pin code 000000 to set new password.
• If the pin code is unknown or forgotten for the Smart Controller or the Smart Shunt the pin can be reset.
To be able to reset the PIN code you will need the enter the unique PUK code for the device to be reset.
The PUK code is printed on the product information sticker on the Smart Controller or Smart Shunt.
For further diagnostics refer to charge controller manual section 9 for detailed troubleshooting or consult dealer for
further assistance.
MY INVERTED OUTLETS ARE NOT POWERED WITH SHORE CORD
DISCONNECTED
• Make sure the inverter disconnect is switched to ON.
• The Victron inverter power switch has 3 settings On, Off, and
Charger Only. Ensure the Victron inverter is switched to ON and
not Charger Only or Off.
• Check to see if any of the branch circuit breakers in the
distribution center are tripped, if so reset.
• Check phone app to verify battery(s) are fully charged at 13.6
for lithium. If batteries are low, charge until full by shore cord, generator, or solar.
For additional troubleshooting refer to inverter troubleshooting guide. Or consult dealer for further assistance.
In partnership with
SOLARFLEX 600i-L BASIC
TROUBLESHOOTING GUIDE
USER MANUAL
VICTRON
• If these conditions are met and the problem remains, consult your dealer for further assistance.
• Ensure inverter disconnect is on.
• Check to see if any of the branch circuit breakers
in distribution center are tripped, if so reset.
MY ROOF AC IS NOT WORKING ON SOLAR OR MY INVERTED OUTLETS ARE
NOT WORKING:
• Ensure the solar panels are clean, in direct sunlight and free from obstruction/debris
• Ensure the batteries are fully charged, 13.6 for lithium
• Ensure the 12V unit battery disconnect black switch is on, located on interior wall near entrance door or in
front storage compartment.

In partnership with
SOLARFLEX 600i-L BASIC
TROUBLESHOOTING GUIDE
I LOST ALL 12V POWER
• The 12V unit battery disconnect is equipped with a Battery Guard Auto that is designed to disconnect the
12V battery system if the battery’s state of charge voltage drops below 11.5 volts for 2 minutes or more.
»Check the battery voltage on the Victron app, if 11.5 V or below, recharge the battery(s). When at least
13.3 Volts charge are applied, after 20 seconds the battery guard will reconnect automatically.
• The factory installed lithium batteries have built in protection and will turn themselves off to prevent
damage due to low voltage. If you find the batteries have dropped to 1-2 Volts you will need to wake
up your batteries.
1) Unplug the shore cord.
2) Turn off the Inverter Disconnect
3) Turn off your battery disconnect (by the red battery heat switch).
4) Check the Cerbo GX, if the lights are off unplug the blue cat6 Ethernet cable on top left of the Cerbo GX
• Now you can plug your shore power back in, turn on your inverter disconnect, the battery disconnect,
and start charging your batteries. Once the inverter starts charging the batteries go ahead and plug in
the blue cat 6 Ethernet cable to the Cerbo GX. Make sure to adjust your charge rate and shore power
setting appropriately.
If these conditions are met and a problem remains, consult your dealer for further assistance.
CERBO GX TROUBLESHOOTING
• For all issues concerning the Cerbo GX unit, refer to troubleshooting section of the Cerbo GX manual
section 13.7
• Ensure the 12V unit battery disconnect black switch is on, located on interior
wall near entrance door or in front storage compartment.
USER MANUAL