Kitchen Kamin KE 90 P Guida rapida

EN Installation, use and maintenance page 2
KE 90 P
PELLET BURNING COOKER

2
ENGLISH
CONTENTS
Introduction 3
Safety information 4
Dimensions 5
Technical data 6
Unpacking 7
Orientation of the fume discharge 8
Installation 10
Instructions for use 15
First ignition procedures 15
Description 16
Interface 17
OFF mode 18
COOKING mode 21
HEATING mode 26
Maintenance 36
In the event of any problems 41
The undersigned company with registered office in Via
Vincenzo Monti 47 - 20123 Milan (Italy) - Tax ID code and VAT
number 00192220192
Hereby declares, under its sole responsibility, that:
the product mentioned below complies with EU Regulation
305/2011 and the harmonised EU standard EN 14785:2006
PELLET BURNING COOKER, trade name KITCHEN KAMIN,
model KE 90 P
SERIAL NO.: Rating plate reference
KE 90 P Performance declaration (DoP EK no. 159):
Rating plate reference
Moreover, the company hereby declares that:
KE 90 P complies with the requirements in the following
European Directives:
2014/35/EC - Low Voltage Directive
2014/30/EC - Electromagnetic Compatibility Directive
The liability of the Manufacturer is limited to supply of the
individual product
USER/INSTALLER
Edition translated from the original version in Italian

3
ENGLISH
Dear Sir/Madam
We thank you for and congratulate you on choosing our
product. Before using it, we ask you to read this manual
carefully, in order for you to be able to make the most of all
its functions in total safety.
This manual is an integral part of the product. We ask you
to keep it for the entire lifetime of the product. If you lose it,
you can request a copy from your dealer or download it from
www.kitchenkamin.com
Readers of this manual
This manual is addressed to:
• those who will use the product at home (“USER”);
• the technician who will install the product (“INSTALLER”)
The target person of each page is indicated in a band at the
bottom of the page (USER or INSTALLER).
General information
After unpacking the product, check the condition and
completeness of the contents.
In the event of error, immediately contact the retailer where
the purchase was made, providing them with a copy of the
warranty booklet and the sales receipt.
The appliance must be installed and operated in compliance
with local and national law and European regulations. For the
installation, and for anything not specifically indicated in the
manual, observe local regulations.
The diagrams provided in this manual are for illustration
purposes only: they do not always strictly refer to your
specific model, and are not binding in any way.
MEANING OF SYMBOLS
In some parts of the manual the following symbols are
used:
INFORMATION:
failure to comply with these requirements
will compromise product use.
PLEASE NOTE:
carefully read and understand the
message in question, since failure to
follow the instructions in it could cause
serious damage to the product and put
the safety of those using it at risk.
OPERATING SEQUENCE:
follow the instructions for the operations
described.
Identication of the product and warranty.
The product is uniquely identified by a number, the
“counterfoil”, which is indicated on the warranty certificate.
Please keep:
• the warranty certificate accompanying the product
• the purchase receipt given to you by the retailer
• the declaration of conformity given to you by the installer.
The warranty conditions are given in the warranty certificate
accompanying the product.
First ignition (commissioning), in Italy, by an
authorised technician is required by UNI 10683, and is
recommended in all countries to ensure best results from
the product.
This consists of:
• checking the installation documents (declaration of
conformity) and the quality of the installation itself
• calibrating the product to suit its actual application
• providing explanations to the end user and issuing
the complementary documentation (first ignition -
commissioning certificate)
Having the appliance commissioned properly ensures that it
will operate to best effect and in complete safety.
Proper commissioning is required for activation of the
manufacturer's warranty. The warranty is only valid in the
country where the product was bought.
If the appliance is not commissioned by an authorised
technician, the manufacturer will not provide warranty service.
See the warranty booklet for details. The above terms do not
affect the dealer's legal responsibility for the legal warranty.
The warranty, however, covers only demonstrable
manufacturing defects and not, for instance, problems
resulting from improper installation or calibration.
USER/INSTALLER

4
ENGLISH
SAFETY INFORMATION
• The product is not designed for use by
people, including children, with limited
physical, sensory and mental abilities.
• The appliance is designed to burn UNI
EN ISO 17225-2 category A1 wood
pellets, in the amounts and manner
described in this manual.
• The appliance is designed for indoor
use and in areas with normal humidity
conditions.
• Keep the product in a dry place out of
the weather.
• For the legal and company warranties,
refer to the warranty certificate inside
the product: specifically, neither the
manufacturer nor the dealer are liable
for damage resulting from incorrect
installation or maintenance.
Safety risks may be caused by:
• installation in non-suitable settings,
in particular those that are subject
to fire risks. DO NOT INSTALL THE
PRODUCT IN AREAS SUBJECT TO
THE RISK OF FIRE.
• Contact with fire and hot parts (e.g.
glass panel and pipes). DO NOT
TOUCH HOT PARTS and, when the
cooker is switched off and still hot,
always wear the gloves supplied.
• Contact with live electrical equipment
(internal). DO NOT ACCESS THE
INTERNAL ELECTRICAL EQUIPMENT
WHILE THE APPLIANCE IS POWERED
ON. Electrocution hazard.
• Use of improper ignition aids (e.g.
alcohol). DO NOT IGNITE OR BOOST
THE FLAME WITH FLUID SPRAYS
OR A FLAME TORCH. Serious risk of
burns, damage and injury.
• Use of fuel other than wood pellets. DO
NOT BURN WASTE MATTER, PLASTIC
OR OTHER MATERIALS THAN WOOD
PELLETS IN THE COMBUSTION
CHAMBER. The product may become
soiled, the flue may catch fire, and
environmental damage may ensue.
• Cleaning the combustion chamber
when hot. DO NOT CLEAN THE
COMBUSTION CHAMBER WITH A
VACUUM CLEANER WHILE IT IS HOT.
You could damage the vacuum-cleaner
and risk the emission of smoke in the
room.
• Cleaning the fumes duct with
cleaning products. DO NOT CLEAN
THE PRODUCT WITH FLAMMABLE
PRODUCTS. Risk of fire or blowback.
• Cleaning the glass pane while hot or
with unsuitable cleaning products.
DO NOT CLEAN HOT GLASS WITH
WATER. ONLY USE RECOMMENDED
GLASS CLEANING PRODUCTS. Risk
of cracking and permanent, irreparable
damage to the glass.
• The storage of flammable materials
at a distance which is less than the
safe distances listed in this manual.
DO NOT PLACE LAUNDRY ON
THE APPLIANCE. DO NOT PLACE
DRYING RACKS WITHIN THE SAFETY
CLEARANCE. Keep flammable fluids
away from the appliance. Fire hazard.
• Blocking the aeration vents and air
intakes in the room. DO NOT BLOCK
THE AERATION VENTS OR FLUE. Risk
of smoke returning into the room with
consequent damage and injury.
• Use of the product as a support or
ladder. DO NOT CLIMB ONTO THE
PRODUCT OR USE IT AS A SUPPORT.
Risk of damage and injury.
• Use of the cooker with the combustion
chamber open. DO NOT USE THE
PRODUCT WITH ITS DOOR OPEN.
• Incandescent material projected
from the open door. DO NOT throw
incandescent material outside the
appliance. Fire hazard.
• Use of water in case of fire. CALL THE
AUTHORITIES if a fire breaks out.
If you have doubts, please do not take
any action, but contact the retailer or the
installer.
For reasons of safety, read the user
instructions included in this manual.
USER/INSTALLER

5
ENGLISH
DIMENSIONS
KE 90 P - DIMENSIONS in cm
- oven size: cm 31 x 41 x 29.5 h; oven capacity 37 litres
- food warmer dimensions: 31 x 20 x 10 h
- cast iron cooktop with 25 cm removable rings: 80 x 48 cm
- glass cooktop: 80 x 48 cm (fume discharge only on the rear)
2
58
60
72.5
34
11.5
90
45
45
45
45
16
Ø 8
Ø 5
External air
connection
4
5
72
86
10
Ø 8 fume
discharge
USER/INSTALLER

6
ENGLISH
The manufacturer reserves the right to modify the product at its own discretion and
without notication.
TECHNICAL DATA EN 14785
Nominal
power
Reduced
power
KE 90 P
Available power 8,6 2,5 kW
Efficiency 86,2 88,0 %
CO emissions at 13% O20,008 0,058 %
Fumes temperature 132 74 °C
Recommended Draught 10 5 Pa
Fuel consumption 2,1 0,6 kg/h
Tank capacity 20 kg
Autonomy 10 33
Heatable volume * 225 m3
Fumes outlet diameter (male) 80 mm
Air intake diameter (male) 40 mm
Weight including packaging 220 kg
TECHNICAL DATA
* The heatable volume is calculated with a heating demand of 33 Kcal/m³ hour and not considering cooking require-
ments
USER/INSTALLER
TECHNICAL DATA FOR RATING THE FLUE which must in any case satisfy the requirements of this sheet
and the installation instructions for the product
Nominal
power
Reduced
power
Fumes temperature at smoke outlet 158 89 °C
Minimum draw 0,01 Pa
Fumes flow rate 11,2 6,7 g/s
ELECTRICAL SPECIFICATIONS
Power 230 Vac +/- 10% 50 Hz
Power absorption during ignition 495 W
Power absorption in “heating” function
(Nominale/reduced power) 180/135 W
Power absorption (nominal power) with
Oven Heating , light, fan ON 1730 W
Protection Fusibile 10 AT, 250 Vac 5x20

7
ENGLISH
UNPACKING
PREPARATION AND UNPACKING
The stove is delivered in a single package containing
the assembled stove and finish options.
• the front and side panels
• the glass or cast iron cooktop
• the profile members
• the stainless steel front handrail (if present)
The packaging materials are neither toxic nor noxious
and do not require special disposal.
The user is responsible for storing, disposing of and
recycling them in a regulatory fashion.
Always move the stove in an upright
position with suitable equipment and in
observance of safety regulations.
Do not turn the package over, and handle
all parts requiring installation with care.
On receiving the delivery, check
In the event of error, immediately contact
the retailer where the purchase was made,
providing him with a copy of the warranty
booklet and the sales receipt.
To remove the cooker from the pallet (see figure below ):
• undo the screws (no. 2) on the rear securing the cooker to the pallet.
The drawings are for guidance only, useful for
the installation or use, but they may not refer
to the specific model.
USER/INSTALLER

8
ENGLISH
ORIENTATION OF THE FUME DISCHARGE
TOP DISCHARGE (1) (not possible with glass cooktop)
The top outlet is a standard installation; no action needed.
REAR DISCHARGE (2) (standard installation and the only one possible with glass cooktop)
To change the fume discharge orientation from top to rear, proceed as follows
Remove the back of the cooker by undoing the 4 screws
Remove the rings and the decorative profile on the discharge. They are not fixed
rings decorative profile
screws
screws
INSTALLER
Undo the 4 screws on the cover which will be placed on top
screws

9
ENGLISH
Unscrew the profile on the discharge
Lift the profile on the discharge (unscrewed in point 3), the gasket and the cast iron cooktop
ORIENTATION OF THE FUME DISCHARGE
Undo the screws on the fume connector and position it towards the back
screws on the fume connector
screws on the fume connector
screws
INSTALLER
Place and screw the cover removed from the rear and position the cast iron cover to close the hole

10
ENGLISH
INSTALLATION
POSITIONING ON THE FLOOR
The stoves are equipped with adjustable feet for
compensating any unevenness in the floor.
Make sure you position the appliance on a level
surface.
Protection from heat and safety clearances
The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
The product must be installed in observance of the
safety conditions shown in the figure, which indicates
the clearances in mm.
If the floor is made of flammable or combustible
material, and not suited to bear the weight of the
appliance, we recommend installing a plate to
distribute the load and to protect the area in front of
the cooker against embers when cleaning it.
CD
min.750
min. 200 min. 200
40
1000
45°
0
55
* Thickness of the insulating material if the
back wall is inflammable (high-temperature
insulating panel with thermal conductivity
below 0.028 W/mK)
*
45°
33
INSTALLER
Indice
Altri manuali Kitchen Kamin Fornello