5 REPAIR
mCAUTION – 75% of all controls
returned for analysis check out OK. Most
control issues are due to loose connections.
5.1 Disassembly / Reassembly
5.1.1 Fascia (control) panel
Carefully pry off four screw cover, remove four T-20 Torx screws and
lift up panel.
5.1.2 Control module
Remove control module from fascia panel progressively from left to
right, carefully releasing inside and outside plastic latches (1-8 below)
so latches don’t break. Gently pry up left side of control so latches
don’t re-close. Module will release from fascia panel and knob.
Don’t cut cable mounts – cut cable ties holding cables to mounts.
When reassembling, use new cable ties.
5.1.3 Top panel (worktop)
Remove two T-20 Torx screws (with washers) from rear of dryer, slide
panel toward rear of dryer (~ ½ cm) and lift up panel. When
reassembling, place panel over two plastic mounting tabs, slide panel
forward and replace two screws.
20
5.1.4 Rear panel
Remove top panel (5.1.3). Remove two T-10 Torx screws holding
rear panel to rear exhaust vent. Remove T-20 Torx screws holding
rear panel to frame and to mains connection sheet. Lift panel out.
Pry moduleLocate module tabs
1
2
3
4
5
6
7
8
Cord terminals
outside dr
e
Mains
connection
sheet RFI filter and
cord terminals