Kleenmaid BSC4530 Guida all'installazione

kitchen collection
Instructions for use and warranty details
Beverage Serving Cabinet
Model No.: BSC4530

Dear Customer,
Thank you and congratulations for choosing
Kleenmaid.
Your new appliance has been designed
and meticulously tested to ensure that it
meets all your culinary requirements, and
has been carefully manufactured using top
quality materials to give you years of reliable
performance.
For best results, carefully read the instructions
on how your new appliance is to be installed.
Correct installation will avoid delays and
unnecessary service call costs.
Once installation is complete, please read this
instruction manual carefully and get to know
the controls and the features of your new
Kleenmaid appliance. These simple instructions
will enable you to achieve excellent results from
the very first time you use it.
Again, congratulations and thank you for
choosing The Best You Can Own.
KLEENMAID

2
CONTENTS
Wine / Beverage Preservation Technology Warnings . . . . . . . . . . . . . . . . . . . 3
Installation of Beverage Serving Cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
General Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Instructions For Left Hinged Door Installation . . . . . . . . . . . . . . . . . . . . . . . . 11
Adjustable Timber Shelving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Switching On Your Beverage Serving Cabinet .. . . . . . . . . . . . . . . . . . . . . . . 14
Temperature Settings.. . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .16
Control Panel Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Auto Lighting Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .17
Wine Serving Temperature Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Defrosting/Condensation/Hygrometry/Ventilation . . . . . . . . . . . . . . . . . . . . . 20
Care and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . 21
Replacing the Carbon Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . 21
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . 22
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . 24
Kleenmaid Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Replacing the LED Light Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Trouble Shooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . 22

Wine / Beverage Preservation Technology
Before using this beverage serving cabinet, please read and follow all safety rules and
operating instructions.
WARNING
Warranty applies to the Beverage Serving Cabinet only and not to the content of the
Beverage Serving Cabinet. The appliance is not covered by the warranty if it is being used
for any purpose other than that for which it was specifically designed. We cannot be held
responsible for any error in this manual, nor be responsible or liable for any spoilage or
damage to wines or any other contents incidental or consequential to possible defects of
the Beverage Serving Cabinet.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Cleaning and user maintenance should not be made by
children without supervision. Children should be supervised to ensure that they do not play
with the appliance.
This appliance has been designed exclusively for storing wine in a domestic setting. Every
other use is considered inappropriate. It should not be used in a commercial environment.
Only wine should be stored inside the appliance. Do not store food or other perishable
items inside this beverage serving cabinet.
Please don't put acidic items, flammable and explosive goods or similar into the
beverage serving cabinet.
This appliance is intended to be used in household and similar applications such as
–staff kitchen areas in shops, offices and other working environments
–farm houses and by clients in hotels, motels and other residential type environments
–bed and breakfast type residential environments
DANGER: Risk of child entrapment. Before you discard your old beverage
serving cabinet:
- Take off the doors
- Leave the shelves in place so that children may not easily climb inside
-When disposing of the appliance, do so only at an authorized waste disposal centre.
3

R600a Refrigerant WARNINGS:
For your safety observe the following recommendations.
This appliance contains a small quantity of R600a refrigerant which is
environmentally friendly, but flammable. It does not damage the ozone layer, nor
does it increase the greenhouse effect.
During transportation and installation, ensure that the tubing of the refrigerant
circuit is not damaged.
Avoid using or manipulating sharp objects near the appliance.
Leaking refrigerant can ignite and may damage the eyes.
In the event any damage does occur, avoid exposure to open fires and any device
which creates a spark. Disconnect the appliance from the mains power.
Thoroughly ventilate the room in which the appliance is located for several
minutes.
Notify Customer Service for necessary action and advice.
The area for installing the appliance must be at least 1 cubic metre per 8 grams of
refrigerant. The refrigerant quantity contained in this appliance is listed in the
Specifications table at the end of this document. It is also noted on the Rating Plate
of the appliance.
It is hazardous for anyone other than an Authorised Service Person to carry out
servicing or repairs to this appliance. In Queensland - the authorised Service Person
MUST hold a Gas Work Authorisation for hydrocarbon refrigerants to carry out
servicing or repairs where the gas system is being opened or charged.
WARNING: This appliance is only suitable for Domestic use and should not be used in a
commercial environment.
WARNING: Keep ventilation openings in the appliance enclosure or in the built-in
structure clear of obstruction.
WARNING: Do not use mechanical devices or other means to accelerate the defrosting
process. Only use methods recommended by the manufacturer.
WARNING: Do not damage the refrigerant circuit.
WARNING: If the machine is not to be used for a lengthy period, please unplug the power
plug from the socket or switch off the power supply.
WARNING: This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the appliance by
a person responsible for their safety;
WARNING: Children should be supervised to ensure that they do not play with the
appliance.
WARNING: Do not use extension cords or ungrounded (two prong) adapters.
WARNING:If the supply cord is damaged, it must be replaced by the manufacturer,
it’s service agent or similarly qualified person in order to avoid hazard.
WARNING: Do not use electrical appliances inside the storage compartments of the
appliance, unless they are of the type recommended by the manufacturer.
WARNING: To avoid a hazard due to instability of the appliance, it must be fixed in
accordance with the instructions.
4

BEFORE LOADING & PLUGGING IN THE BEVERAGE SERVING CABINET
Allow 24 hours before switching on the beverage serving cabinet. During this time
we recommend that you leave the door open to clear any residual odours.
Important: BSC4530 is for integrated or built in use only.
Recommendations:
The location you have selected for your Beverage Serving Cabinet should:
- be unencumbered and well ventilated;
- be well away from any heat source and direct sunlight;
- not be too damp (laundry, bathroom etc.);
- have a standard and reliable electricity supply (standard AUearthed socket). Use of
apower board or extension lead is not recommended.
- have a surge protector fitted to the electrical outlet.
The Beverage Serving Cabinet should be placed where the ambient temperature is within
the range stated in the Specifications table at the end of this manual. If the temperature is
above or below this range, it will affect the performance of the cabinet. Placing the cabinet
in very cold or hot temperature conditions may cause the cabinet’s temperature to
fluctuate, and not maintain the ideal temperature.
Grounding instructions:
The Beverage Serving Cabinet must be earthed in order for RCD safety switch to operate
correctly and is required by law. Earthing reduces the risk of electrical shock. The
Beverage Serving Cabinet is equipped with a power cord having an earthing wire and
plug. The Beverage Serving Cabinet plug must be plugged into a properly affixed and
earthed electrical outlet.
Note: In locations where there are frequent lightning storms, it is advisable to use surge
protectors.
Improper use of the earthed plug can result in the risk of electric shock. Consult a qualified
electrician or service person if the earthing instructions are not completely understood.
If the supply cord is damaged, it must be replaced by a qualified person in order to avoid
electrical hazard.
5

INSTALLING YOUR BEVERAGE SERVING CABINET
Unpack and remove all of the protection and adhesive strips from the packaging around
and inside the Beverage Serving Cabinet.
The Beverage Serving Cabinet must be positioned so that the plug is accessible.
Release the power cord. Move your Beverage Serving Cabinet to its final location. The
Beverage Serving Cabinet should be installed in a suitable place where the compressor
will not be subject to physical contact.
Leveling your Beverage Serving Cabinet: The base of the cabinet in which the Beverage
Serving Cabinet is installed must be level so the BSC4530 is level BEFORE loading wine.
GENERAL INSTRUCTIONS
1.Built in Beverage Serving Cabinets are front venting but are not designed to be fully
integrated behind a joinery door.
2.Please follow the installation diagram when installing built-in Beverage Serving Cabinets.
Observe the minimum installation dimensions, or it will affect the venting of cooler.
3.Built-in Beverage Serving Cabinets draw air from right of the ventilation frame and expel
through left of the ventilation frame.
4.Built in Beverage Serving Cabinets have a power switch located on the control panel.
5.The Beverage Serving Cabinet requires a standard 230 volt/10 amp power point.
6.The power cord is 2.0m in length and is fixed on the right side at the back when looking
from front of the cabinet.
7.As with many appliances of today, the Beverage Serving Cabinet has sensitive electronic
components which are susceptible to damage through lightning and electricity supply faults.
It is therefore advisable to use a power surge protector to avoid problems of this nature.
8.When a wood door is installed an air vent must be provided on the door for built-in
Beverage Serving Cabinets
In hot climate zones, an air vent or grid, with a minimum ventilation size of 200mm x 40mm
MUST be cut out at the rear top of the back partitioning or at the top of either side of the
partitioning, allowing cool fresh air full access to flow into the 30mm gap located at the rear
of the cabinet.
This air vent or grid must not be opened on the same side as other appliances such as ovens
or an area that is sealed and without access to fresh cool air. Failing to comply with the
above specifications could result in voiding the Warranty.
6

INSTALLATION DRAWINGS
Note: The appliance must be positioned so that the plug is accessible after installation.
DIMENSIONAL DRAWINGS:
As BSC4530 is a built-in model inside a cabinet, the cabinet should have good ventilation
space and no back panel, otherwise it will affect the functioning of the cabinet. (Installation
drawing as below)
The ventilation distance should
be at least 50 mm.
mm
7

INSTALLATION DRAWINGS
8

OPENING ANGLE
9
Indice

















