Specifications
Ambient Temperature Max 104°F (40°C)
Maximum Relative Humidity 90% non-condensing
Electrical Service 120 VAC, 50/60 Hz, 1.3 A Max
Power Cable Length 36″(914 mm)
Data Cable Length 6’ (1.83 m)
Output Power 90 Watts total
Frequency Response 20 Hz - 18 kHz +/- 3dB
Signal/Noise Ratio >75 dB
Total Harmonic Distortion <0.1% at 1 Watt, <1% at full output
power
Tools and Materials
Before you Begin
WARNING: Risk of electric shock. Disconnect power before
servicing.
CAUTION: Risk of product damage. The amplifier is rated to
operate in temperatures up to 104°F (40°C). Do not install near heat
sources (such as radiators or heat registers) or in any location where
the temperature may exceed 104°F (40°C).
CAUTION: Risk of product damage. A network cable is provided
with this product. For all bath installations with combined user
experiences, you must use the supplied cable in place of the cable
shipped with the bath. Failure to do so may cause irreparable
damage to the amplifier.
• Wire Cutter/Stripper
Plus:
1298482-2-C 2 Kohler Co.

Before you Begin (cont.)
NOTICE: This product is not water-resistant. Do not install in a
location where excessive moisture, high humidity levels, or
condensation are present.
NOTICE: Follow all electrical and building codes.
NOTICE: Provide unrestricted service access to the amplifier.
NOTICE: Provide a minimum of 6″(152 mm) of space around the
amplifier for proper air flow.
Determine amplifier and speaker locations before beginning
installation. Test the BLUETOOTH
®
range between the amplifier
and your wireless device when determining amplifier location.
Under normal conditions, the maximum range is 30’ (9.14 m).
The amplifier can be mounted in any orientation. Use the
supplied brackets or rubber feet to accommodate your mounting
configuration.
Locate the amplifier within close proximity to a 15 A 120 V
electrical outlet. Install a GFCI or RCD electrical outlet within the
stud framing and within 24″(610 mm) of the amplifier.
A qualified electrician should install an electrical outlet.
Install the electrical outlet prior to installing the amplifier.
This amplifier complies with CE, FCC, IC, and RoHS.
Kohler Co. 3 1298482-2-C

1. Preparation
NOTE: To play your personal music files, a wireless BLUETOOTH
device or a device with a 3.5 mm stereo cable connection is required.
Plan the location of the amplifier to allow access to the front and
back ports.
Allow adequate reach for wires between the bath and the
amplifier.
Make sure the status LED will be visible after installation.
NOTICE: The circular auxiliary-in port is not an Ethernet
communication port. Do not connect an Ethernet network to the
auxiliary-in port. Use the auxiliary-in port only for a standard
accessory.
Status LED
AC Power Supply
User Interface
Amplifier
Auxiliary-In Cable
Chromatherapy Cable In
Transducers
1298482-2-C 4 Kohler Co.

2. Installation
CAUTION: Risk of product damage. The amplifier is rated to
operate in temperatures up to 104°F (40°C). Do not install near heat
sources (such as radiators or heat registers) or in any location where
the temperature may exceed 104°F (40°C).
NOTICE: Mount the amplifier in a dry location, and provide a
minimum of 6″(152 mm) of space for proper air flow.
NOTE: Choose the mounting location to best suit the location of the
incoming transducer wires and other cables.
NOTE: Make sure the status LED will be visible after installation.
Mounting Options
Wall-mount: Secure the amplifier in an upright position using the
mounting brackets, anchors, and short screws provided.
Cabinet-mount: Secure the amplifier in an upright position using
the mounting brackets and short screws provided.
Cabinet-Mount
Under-MountSurface-Mount
Wall-Mount
Kohler Co. 5 1298482-2-C

Installation (cont.)
Surface-mount: Attach the four rubber feet to the underside of
the amplifier to protect against scratching your shelf or
countertop surface.
Under-mount: Secure the amplifier in position using the
mounting brackets and short screws provided.
Bracket Installation
Position the amplifier with attached brackets in the desired
location.
Mark the bracket hole locations with a pencil.
Drill pilot holes or insert anchors as needed at the marked
locations.
Secure the brackets using the four screws provided.
1298482-2-C 6 Kohler Co.

3. Amplifier Connection
CAUTION: Risk of product damage. Use the network cable
provided with the amplifier for installation with baths having more
than one user experience (whirlpool, vibracoustic, air bath, etc.). For
these installations, remove and discard the network cable assembled
to the bath, and replace it with the new network cable. Failure to
replace the network cable may cause irreparable damage to the
amplifier.
IMPORTANT! A network cable is provided with this product.
Depending upon the type of bath product being installed, use this
cable to connect the amplifier and user interface, or to connect the
bath and user interface. Refer to the bath Homeowners Guide or the
bath product page on kohler.com to determine the bath type being
installed.
NOTE: The transducer terminals and wires are numbered to
identify the correct connections. When required, the amplifier can be
removed to aid in the wire connection process.
NOTICE: The circular auxiliary-in port is not an Ethernet
communication port. Do not connect an Ethernet network to the
auxiliary-in port. Use the auxiliary-in port only for a standard
accessory.
Disconnect the power from the amplifier.
If equipped, connect the chromatherapy connector from the bath
to the chromatherapy connection on the amplifier.
Power
Cable
Transducer
Terminals
User Interface
Connection
BACKFRONT
Auxiliary-In
Port
Chromatherapy
Connection
Status LED
Kohler Co. 7 1298482-2-C

Amplifier Connection (cont.)
Connect the transducer wires to the transducer terminals on the
amplifier. The white wires with black stripes are connected to the
positive (+) terminals, and the solid white wires are connected to
the negative (-) terminals.
Connect the clear connector of the user interface cable to the
amplifier user interface connection.
If used, connect the auxiliary-in cable to the auxiliary-in port on
the amplifier.
Reconnect the power to the amplifier.
Verify that the status LED turns on.
1298482-2-C 8 Kohler Co.

4. Operation
When using the auxiliary-in, set your music device to midrange
volume after connecting to the amplifier, but before sending an
audio signal from the device.
To listen to a BLUETOOTH source, go to the AUX screen of the
user interface. Activate by pressing the AUX icon.
A wireless BLUETOOTH source will override an auxiliary-in
source.
When listening to an auxiliary-in source, a tone will be heard
when a BLUETOOTH device is paired with the amplifier. The
tone indicates that the auxiliary-in source is no longer active.
To listen to an auxiliary-in source, the BLUETOOTH source must
be un-paired from the amplifier.
When listening to a BLUETOOTH device which is paired with the
amplifier, a tone will be heard when the BLUETOOTH device has
unpaired from the amplifier and is no longer active.
Status LED Light
Yellow blink = Amplifier error: Contact the Customer Care
Center.
Blue blink = Stand-by mode: Normal operation - No
BLUETOOTH connection.
Blue solid = Normal operation: BLUETOOTH receiver is paired
with a device.
Green blink = User interface error - For example, loose or
disconnected cable.
Power
Cable
Transducer
Terminals
User Interface
Connection
BACKFRONT
Auxiliary-In
Port
Chromatherapy
Connection
Status LED
Kohler Co. 9 1298482-2-C

Operation (cont.)
3.5 mm Stereo Input
A wired audio device can be connected to the auxiliary-in port on
the amplifier.
Audio input may be slightly delayed when a device is initially
connected.
Wireless Input
Once a BLUETOOTH device is paired, the LED will be solid blue
and the audio input will fade-in.
On the BLUETOOTH user device, the amplifier will display as
″VibrAcoustic.″
If a BLUETOOTH pin number is required, use ″0000.″
NOTE: For more information on system operation, refer to the
Homeowners Guide.
Troubleshooting
IMPORTANT! Turn off the power supply before performing any
maintenance.
NOTE: For service parts information, visit your product page at
kohler.com/serviceparts.
This troubleshooting guide is for general aid only. For service and
installation issues or concerns, call 1-800-4KOHLER.
Troubleshooting Table
Symptoms Probable Cause Recommended Action
1. One or more
transducers do
not produce
sound.
A. Transducer wire is
not connected
properly.
A. Make sure the wires
are properly
connected to the
amplifier. Each
transducer has a
white with black
wire which is the
positive (+) lead, and
a solid white wire
which is the negative
(-) lead.
1298482-2-C 10 Kohler Co.