Labconco 3980200 Manuale utente

Purifier®HEPA Filtered Enclosures
& Purifier®Class I Filtered
Enclosures
User’s Manual
Labconco’s Mascot,
Labby the LABster
Register your product online at
www.labconco.com/productreg.html
or return the attached card and
receive FREE LabbyWear™!
Models
3980200, 3980201, 3980202, 3980203, 3980220,
3980221, 3980222, 3980223, 3980300, 3980301,
3980302, 3980303, 3980320, 3980321, 3980322,
3980323, 3980400, 3980401, 3980402, 3980403,
3980420, 3980421, 3980422, 3980423


Labconco HEPA Filtered Enclosure Manual
Warranty
Labconco provides a warranty on all parts and factory workmanship. The warranty includes areas of
defective material and workmanship, provided such defect results from normal and proper use of the
equipment.
The warranty for all Labconco products will expire one year from date of installation or two years from
date of shipment from Labconco, whichever is sooner, except the following:
• Purifier® Delta® Series Biological Safety Cabinets and PuriCare® Animal Laboratory Research
Enclosures carry a three-year warranty from date of installation or four years from date of
shipment from Labconco, whichever is sooner.
• Carts carry a lifetime warranty.
• Glassware is not warranted from breakage when dropped or mishandled.
This limited warranty covers parts and labor, but not transportation and insurance charges. In the event of a
warranty claim, contact Labconco Corporation or the dealer who sold you the product. If the cause is
determined to be a manufacturing fault, the dealer or Labconco Corporation will repair or replace all
defective parts to restore the unit to operation. Under no circumstances shall Labconco Corporation be
liable for indirect, consequential, or special damages of any kind. This statement may be altered by a
specific published amendment. No individual has authorization to alter the provisions of this warranty
policy or its amendments. Lamps and filters are not covered by this warranty. Damage due to corrosion or
accidental breakage is also not covered.
Limitation of Liability
The disposal and/or emission of substances used in connection with this equipment may be governed by
various federal, state, or local regulations. All users of this equipment are required to become familiar with
any regulations that apply in the user’s area concerning the dumping of waste materials in or upon water,
land, or air and to comply with such regulations. Labconco Corporation is held harmless with respect to
user’s compliance with such regulations.
.
Part #3905500, Rev. A
ECO C415

T
TA
AB
BL
LE
E
O
OF
F
C
CO
ON
NT
TE
EN
NT
TS
S
CHAPTER 1: INTRODUCTION 1
About This Manual 2
Typographical Conventions 3
CHAPTER 2: PREREQUISITES 5
Support, Vibration & Movement Requirements 6
Location and Air Current Requirements 6
Exhaust & Blower Requirements 6
ElectricalRequirements 7
Space Requirements 7
CHAPTER 3: GETTING STARTED 9
Unpacking Your Enclosure 10
Installing the Filtered Enclosure on a Supporting
Structure and Work Surface 10
Connecting to the Exhaust System (Optional) 13
Installation of HEPA Filters and Accessory Odor-
Control Carbon Filters 15
Connect the Electrical Supply Source to Filtered Enclosure 16
Set the Face Velocity with Speed Control Adjustment 17
Validating the Vented Enclosure 17
Sealing the Filtered Enclosure to the Work Surface 18
CHAPTER 4: HIGH PERFORMANCE FEATURES AND
SAFETY PRECAUTIONS 19
Components 20
Safety Precautions 27
CHAPTER 5: APPROPRIATE APPLICATIONS FOR YOUR
FILTERED ENCLOSURE 31
Routine Daily Work Procedures 31
SuitableApplications 33
HEPA Filter Applications, Suitability & Guidelines 33
Odor Control Carbon Filter Applications 34
DefinitionofTerms 35
Appropriate Chemicals for Odor Control Carbon Filters 36
Hazardous Misapplications for Odor Control Carbon
Filters with Volatile Chemicals 37
Chemical Carcinogen Use with Odor Control
Carbon Filters 37

ProhibitedAcidUse 38
CHAPTER 6 MAINTAINING YOUR FILTERED ENCLOSURE 39
Routine Maintenance Schedule 40
Decontamination 41
Determination of when to Replace HEPA Filters 41
How to Install a New HEPA Filter 42
HEPA Filter Leak Test 44
Setting the Inflow Face Velocity with the Speed Control
Adjustment 46
Calibrate and Operate the Airflow Monitor 46
Determination of When to Replace Odor control
Carbon Filters and How to Replace 50
Calculating Odor control Carbon Filter Life 52
Initial Certification 53
Re-Certification 53
Fluorescent Light Replacement 54
UV Light Replacement 54
Motorized Impeller Replacement 54
Speed Control Replacement 56
CHAPTER 7 ACCESSORIZING & MODIFYING YOUR
FILTERED ENCLOSURE 57
CHAPTER 8 TROUBLESHOOTING & SERVICER
OPERATINGLOG 63
APPENDIX A: FILTERED ENCLOSURE COMPONENTS
AND REPLACEMENT PARTS 67
APPENDIX B: DIMENSIONS AND EXHAUST OPTIONS 72
APPENDIX C: FILTERED ENCLOSURE SPECIFICATIONS 75
APPENDIX D: QUICK CHART FOR THE FILTERED
ENCLOSURES 81
APPENDIX E: REFERENCES ON VENTILAITON, SAFETY,
OCCUPATIONAL HAZARDS, BIOSAFETY
AND DECONTAMINATION 82
DECLARATION OF CONFORMITY 87

1
C
CH
HA
AP
PT
TE
ER
R
1
1
I
IN
NT
TR
RO
OD
DU
UC
CT
TI
IO
ON
N
Congratulations on your purchase of a Labconco Purifier® HEPA
Filtered Enclosure or Purifier® Class I Filtered Enclosure. Your
enclosure provides personnel protection through superior
containment. It is the result of Labconco’s more than 50 years
experience in manufacturing fume hoods and more than 30 years
experience in manufacturing filtered enclosures.
These enclosures will effectively contain toxic, noxious, or
biohazardous particulates when properly installed and operated.
Each enclosure uses a single HEPA filter, which is rated at least
99.99% efficient for 0.3-micron particles. Additionally, an
accessory Odor Control carbon filter may be added to adsorb
nuisance odors from organic vapors, formaldehyde or ammonia
and amines. The Purifier enclosures offer many unique features to
enhance safety, performance, and energy savings. To take full
advantage of them, please acquaint yourself with this manual and
keep it handy for future reference. If you are unfamiliar with how
high performance HEPA filtered enclosures operate, please review
Chapter 4: High Performance Features and Safety Precautions
before you begin working in the enclosure. Even if you are an
experienced user, please review Chapter 5: Using Your HEPA
Filtered Enclosure, which describes the Purifier features so that
you can use the filtered enclosure efficiently. For hazardous
biological applications requiring user protection but not product
protection, Labconco recommends the purchase of a Class I
enclosure, which includes a UV light for general surface
decontamination. For general hazardous biological applications,

2
Chapter 1: Introduction
particulates, and nuisance powders, Labconco recommends the use
of the Purifier HEPA Filtered Enclosure. See chart below and
contact Labconco for additional ordering information.
No. Application Product Filters
Bag-in/Bag-out
HEPA
UV
Light
1. Nuisance Powders,
Biohazardous
Materials
Purifier HEPA
Filtered
Enclosure
HEPA NO
Decontamination
Required
NO
2. Nuisance Powders,
Biohazardous &
Volatile Chemicals
Purifier HEPA
Filtered
Enclosure
HEPA
and
Carbon*
NO
Decontamination
Required
NO
3. Biohazardous
Materials & Nuisance
Powders
Purifier Class I
Enclosure
HEPA NO
Decontamination
Required
Included for
Surface
Decontamination
4. Biohazardous
Materials, Nuisance
Powders & Volatile
Chemicals
Purifier Class I
Enclosure
HEPA
and
Carbon*
NO
Decontamination
Required
Included for
Surface
Decontamination
* It is recommended that a Labconco product specialist review the
chemical application to determine if it is suitable. Consult Chapter
5 and Chapter 6.
About This Manual
This manual is designed to help you learn how to install, use, and
maintain your filtered enclosure. Instructions for installing
optional equipment or accessory carbon filters on your filtered
enclosure are also included.
Chapter 1: Introduction provides a brief overview of the filtered
enclosure, explains the organization of the manual, and defines the
typographical conventions used in the manual.
Chapter 2: Prerequisites explains what you need to do to prepare
your site before you install the filtered enclosure. Electrical and
service requirements are discussed.
Chapter 3: Getting Started contains the information you need to
properly unpack, inspect, install, and certify the filtered enclosure.
Chapter 4: High Performance Features and Safety Precautions
explains how the Purifier filtered enclosure operates and the
appropriate precautions you should take when using it.

3
Chapter 1: Introduction
Chapter 5: Using Your Filtered Enclosure discusses the basic
operation of how to prepare, use and shut down your filtered
enclosure.
Chapter 6: Maintaining Your Filtered Enclosure explains how to
perform routine maintenance on the filtered enclosure.
Chapter 7: Accessorizing Your Filtered Enclosure explains
acceptable modifications to the filtered enclosure or how to add
accessories.
Chapter 8: Troubleshooting contains a table of problems you may
encounter while using the filtered enclosure including the probable
causes of the problems and suggested corrective actions.
Appendix A: Components and Replacement Parts contains labeled
diagrams of all of the components of the filtered enclosures.
Appendix B: Dimensions and Exhaust Options contains
comprehensive diagrams showing all of the dimensions for the
filtered enclosures.
Appendix C: Filtered Enclosure Specifications contains the
electrical requirements for filtered enclosures. Wiring diagrams
are also included.
Appendix D: Quick Chart provides a table of airflow and test data
for the filtered enclosures.
Appendix E: References lists the various resources available that
address laboratory ventilation and biosafety.
Typographical Conventions
Recognizing the following typographical conventions will help
you understand and use this manual:
• Book, chapter, and section titles are shown in italic type (e.g.,
Chapter 3: Getting Started).
• Steps required to perform a task are presented in a numbered
format.
• Comments located in the margins provide suggestions,
reminders, and references.
• Critical information is presented in boldface type in paragraphs
that are preceded by the exclamation icon. Failure to comply !

4
Chapter 1: Introduction
• with the information following an exclamation icon may result
in injury to the user or permanent damage to the enclosure.
• Critical information is presented in boldface type in paragraphs
that are preceded by the wrench icon. A trained certifier or
contractor should only perform these operations. Failure to
comply with the information following a wrench icon may
result in injury to the user or permanent damage to your hood.
• Important information is presented in capitalized type in
paragraphs that are preceded by the pointer icon. It is
imperative that the information contained in these paragraphs
be thoroughly read and understood by the user.
• A number icon precedes information that is specific to a
particular model of enclosure. The 2' icon indicates the text is
specific to the 2-foot wide model. The 3' icon indicates the text
is specific to the 3-foot model, etc.
☞
2' 3' 4'

5
C
CH
HA
AP
PT
TE
ER
R
2
2
P
PR
RE
ER
RE
EQ
QU
UI
IS
SI
IT
TE
ES
S
Before you install the filtered enclosure, you need to prepare your
site for installation. You must be certain that the area is level and
of solid construction. In addition, a dedicated source of electrical
power should be located near the installation site to power the
filtered enclosure, and other apparatus. Additionally, the enclosure
should be strategically placed in the lab to provide efficient
workflow.
Carefully read this chapter to learn the requirements for your
installation site:
• The support, vibration and movement requirements.
• The location and air current requirements.
• The exhaust and blower requirements.
• The electrical power requirements.
• The space requirements.
Refer to Appendix B: Purifier Dimensions for complete enclosure
dimensions.
Refer to Appendix C: Purifier Specifications for complete filtered
enclosure electrical and environmental conditions, specifications
and requirements.
Questo manuale è adatto per i seguenti modelli
23
Indice
Altri manuali Labconco Allegato