TABLE OF CONTENTS
GENERAL SAFETY WARNINGS 4
GENERAL SAFETY OBLIGATIONS 4
1) DESCRIPTION OF THE MODELS 5
2) TECHNICAL SPECIFICATIONS 5
MECHANICAL SECTION
3) NEPTIS PLUS AUTOMATION COMPONENTS 6
4) PRELIMINARY CHECKS 7
5) TECHNICAL DRAWINGS 8
5.1) ASSEMBLY OF THE AUTOMATION ON THE TRANSOM FROM THE HINGE SIDE 8
5.2) ASSEMBLY OF THE AUTOMATION ON THE TRANSOM FROM THE HINGE SIDE 9
5.3) ASSEMBLY OF THE AUTOMATION ON THE TRANSOM FROM THE HINGE SIDE 10
5.4) ASSEMBLY OF THEAUTOMATION ON THE TRANSOM FROM THE SIDE OPPOSITE TO THE HINGE 11
5.5) ASSEMBLY OF THE AUTOMATION ON THE LEAF FROM THE HINGE SIDE 12
5.6) ASSEMBLY OF THE AUTOMATION ON THE TRANSOM FROM THE HINGE SIDE 13
6) MOVEMENT TRANSMISSION ARMS 14
6.1) SLIDE PULLARM BDT2 14
6.3) SHORT SLIDE PULLARM BDT2R55 15
6.4) SLIDING GUIDE FOR PULL ARM 15
6.5) BSS2 ARTICULATED PUSH ARM 15
6.6) EXTB-Z TAPERED PIN 16
6.7) EXTENSION FOR EXTB-Z TAPERED PIN 16
7) PREPARATION AND INSTALLATION OF THE AUTOMATION 17
7.1) TOOLS REQUIRED: 17
7.2) AUTOMATION CHECK 17
7.3) AUTOMATION INSTALLATION 18
7.4) CHOICE OF THE SPRING LOAD (FOR NEPTIS PLUS NB-LET, NB-LETB, NB-SLT, NB-SLTB AUTOMATIONS ONLY) 18
7.5) INSERTION OF THE ARM TAPERED PIN 18
7.6) SPRING RELEASE (FOR NEPTIS PLUS NB-LET, NB-LETB, NB-SLT, NB-SLTB AUTOMATIONS ONLY) 18
8) ARM REMOVAL 19
9) NEPTIS PLUS AUTOMATIONS WITH BATTERY (SLTB, LETB, SMTB MODELS) 20
10) SPRING PRE-LOAD RESETTING PROCEDURE (FOR SLT, SLTB, LET, LETB MODELS ONLY) 21
ELECTRONICS
11) ELECTRIC ARRANGEMENTS 22
12) ELECTRIC CONNECTIONS 23
13) PWB ELECTRICAL WIRING AND POWER SUPPLY MODULE 24
13.1) LOGIC CARD LCB 26
14) DIGITAL SELECTOR ET-DSEL – PURPOSE AND CONNECTIONS 26
15) SAFETY SENSORS 27
15.1) SAFETY SENSOR OA-EDGE T 27
15.2) FLAT SCAN SAFETY SENSOR 27
16) COMMISSIONING OF THE AUTOMATION (INITIAL SETUP) 28
16.1) FIRST START OF THE DIGITAL SELECTOR ET-DSEL 28
16.2) SERIAL COMMUNICATION SETTINGS 28
16.3) INITIAL SETUP 29
16.4) FUNCTIONAL TESTING 31
16.5) INPUT DIAGNOSTICS 31

17) PROGRAM SELECTORS 32
17.1) MANUAL PROGRAM SELECTORS 32
17.2) MECHANICAL KEY SELECTOR EV-MSEL 32
17.3) DIGITAL SELECTOR ET-DSEL– USED AS PROGRAM SELECTOR 33
18) GENERAL PROGRAMMING MENU 35
19) FUNCTIONS AND SETTINGS 36
19.1) FUNCTIONS SETTING 36
19.2) - POTENTIOMETER ADJUSTMENT 36
20) LANGUAGE 44
21) PASSWORD MANAGEMENT 44
21.1) HOW TO CHANGE THE TECHNICAL PASSWORD 45
21.2) HOW TO CHANGE THE PRIMARY PASSWORD 45
21.3) HOW TO CHANGE THE SERVICE PASSWORD 46
21.4) ENABLING USER PASSWORD USAGE (PRIMARY AND SERVICE) 47
21.5) DISABLING USER PASSWORD USAGE 47
22) SELECTOR OPTIONS 48
23) INFORMATION AND EVENT MEMORY 49
24) MAINTENANCE 52
24.1) PLUG AND PLAY 52
25)APPLICATIONS WITH ELECTRIC LOCK 53
25.1) ELECTRIC LOCK / ELECTRIC STRIKE 53
25.2) ELECTROMAGNET 53
26) DUAL LEAF DOOR 54
26.1) DUAL LEAF ELECTRIC SETUP 54
26.2) DUAL LEAF DOOR COMMISSIONING 54
26.3) FUNCTIONAL TESTING 57
26.4) PARTIAL OPENING 57
26.5) CONSIDERATIONS ABOUT THE USE OF THE SELECTOR ET-DSEL OF THE TWO-LEAF DOOR 58
26.6) MASTER / SLAVE INPUTS DIAGNOSTICS 58
27) EN-RF1 RADIO RECEIVER 59
28) COURTESY MODE FOR DISABLED 60
29) NB-BAT BATTERY MODULE 61
30) INTERLOCK SYSTEM 62
30.1) ELECTRICAL CONNECTION FOR INTERLOCK 62
30.2) OPERATION OF THE INTERLOCK SYSTEM 62
30.3) INTERLOCK APPLICATION WITH A SINGLE INTERNAL DETECTOR 63
30.4) INTERLOCK APPLICATION WITH ELECTRIC LOCKS DISABLED WITH CLOSED DOORS 63
31) PRIVACY FUNCTION 64
31.1) ELECTRIC CONNECTIONS 64
31.2) OPERATION OF THE PRIVACY SYSTEM 65
31.3) SETTINGS 65
32) MEANING OF BUZZER AUDIBLE SIGNALS 66
33) MAINTENANCE PROGRAM 66
DECLARATION OF INCORPORATION OF PARTLY ASSEMBLED MACHINERY 67

4
GENERAL SAFETY WARNINGS
Carefully read this instruction manual for the safe installation and operation of the automatic door.
Improper installation and incorrect use of the product could cause serious injury.
Keep the instruction manual for future reference.
The installer must provide all the information about operation and provide the system user with the user manual delivered with the
product.
MEANING OF THE SYMBOLS USED IN THESE INSTRUCTIONS
DANGER:
Notication of dangerous situations that could cause material damage and personal injury.
WARNING:
Identies the procedures that must be understood and followed mandatorily in order to avoid damage to the product or
malfunctions.
NOTE:
Highlights important information.
GENERAL SAFETY OBLIGATIONS
The mechanical and electric installation must be performed by specialised personnel in accordance with the applicable
directives and regulations.
The installer must make sure that the structure to be automated is stable and sturdy and, if necessary, make structural
modications to make it so.
Keep product and packaging materials out of children's reach, as they might be a source of danger.
Do not let children stay or play within the operating range of the door.
This product is designed and built exclusively for the purpose described in this documentation. Any other use that is not specically
indicated could adversely impact the condition of the product and the safety of people.
Label accepts no responsibility for incorrect product installation and usage, as well as for any damage caused by changes made without
its prior consent.
Label is not responsible for the construction of the frames to be motorised.
The IP32 protection class requires that the automation is installed only on the inner side of buildings.
This product cannot be installed in explosive environments or atmospheres, or in the presence of ammable gases or fumes.
Make sure that the characteristics of the electric distribution network are compatible with the technical data indicated in this manual and
that upstream of the system there is an omnipolar switch with an opening distance of the contacts of at least 3mm and a residual current
device.
The automatic door must be checked, started up, and tested by personnel skilled and trained about the product.
A technical dossier must be compiled for every automation, as established in the Machinery Directive.
Disconnect the power supply before working on the automation and before opening the cover.
Maintenance is of fundamental importance for the proper operation and safety of the automation. Check the eciency of all parts every
six months.
Use only original spare parts for maintenance and when replacing product components.
Cleaning operations must be performed with the power supply disconnected, using a damp cloth. Do not deposit or let water or other
liquids penetrate into the automation or the accessories that are part of the system.
It is recommended to subscribe a maintenance contract.
The automatic swing doors must be designed and installed so as to protect users against the risk and danger of crushing,
impact, and shearing between the leaf and adjacent parts near the door outline.
The person responsible for starting-up the automation must perform a risk assessment based on the place of installation
and the type of users that could use the automatic door.
The automation Neptis Plus, as provided for by the standard EN16005, must be equipped with the safety devices (sensors)
compliant with the standard EN12978.
A = Main closing edge
B = Secondary closing edge
C = Opposite closing edge
The crushing and shearing dangers on the secondary closing edge must be protected structurally or
by means of additional safety provisions (e.g., rubber covers).
Any residual risks must be properly highlighted.

5
1) DESCRIPTION OF THE MODELS
The automation Neptis Plus consists of an electro-mechanical motor to open pedestrian swing doors.
According to the type of automation, the door may be re-closed by a spring or by a motor.
The electronic control equipment is located inside the automation.
A list of the automation models for Neptis Plus swinging doors produced by Label is provided below:
• NB-SLT
with re-closure spring, for leaves weighing no more than 250Kg.
• NB-SLTB
with built-in emergency battery, re-closure spring, for leaves weighing no more than 250Kg.
• NB-LET
with re-closure spring, for leaves weighing no more than 120Kg.
• NB-LETB
with built-in emergency battery, re-closure spring, for leaves weighing no more than 120Kg.
• NB-SMT
motor-driven closing only, for leaves weighing no more than 250Kg.
• NB-SMTB
with built-in emergency battery, motor-only closure, for leaves weighing no more than 250Kg.
All Neptis Plus automation models can be used with slide pull arm, or with articulated push arm.
The choice of the model depends on the weight and length of the door leaf, on the desired re-closure type (spring-driven or motor-driven
only) and on whether the emergency battery is required.
The automation must be installed in indoor environments.
All models are reversible, so in case of power failure it is possible to open the door manually.
Before starting installation, refer to the technical drawings in paragraph 5; for each type of arm they include the application design with
installation dimensions and the chart that, depending on the automation model, provides the weight limits based on the length of the door
leaf.
The technical data provided in the drawings refers to a typical installation, but may be inuenced by variables inherent to each closing,
such as friction, environmental conditions, alignment of the leaf hinges, etc....
2) TECHNICAL SPECIFICATIONS
POWER SUPPLY 115/230V~, 50-60Hz
POWER 100W
POWER SUPPLY OF EXTERNAL ACCESSORIES 24Vdc, 1A
BRUSHLESS MOTOR 24Vdc
AUTOMATION SIZE (LxHxD) 550 x 110 x 120 mm
DIMENSIONS OF AUTOMATION with BATTERY (LxHxD) 730 x 110 x 120 mm
WEIGHT OF MOD. NB-SLT, NB-LET, NB-SMT 9.5 Kg
WEIGHT OF MOD. NB-SLTB, NB-LETB, NB-SMTB 11 Kg
PROTECTION CLASS IP31
AMBIENT TEMPERATURE -15°C +50°C
FREQUENCY OF USE continuous
LIMIT SWITCH AND ANTICRUSH SAFETY controlled by encoder
REACTION TO OBSTACLES reversal of direction
OPENING TIME FOR 95° 3 - 12 seconds adjustable
CLOSING TIME FOR 95° 4 - 15 seconds adjustable
TORQUE < 40 Nm
STAND-BY CONSUMPTION 6W
SOUND PRESSURE EMISSION LpA < 70dB (A)

6
3) NEPTIS PLUS AUTOMATION COMPONENTS
LEGEND: 1 LOGIC CARD LCB
2 PWB ELECTRICAL WIRING AND POWER SUPPLY CARD
3 RE-CLOSURE SPRING (MODELS NB-SLT, NB-LET)
4 SPRING PRELOAD REFERENCE LINE
5 BRUSHLESS GEARMOTOR
6 MOTION TRANSMISSION SHAFT OUTLET
7 INTERNAL WIRING BETWEEN LCB AND PWB CARDS
8 SPRING PRELOAD LOCKING SCREW
9 PLASTIC PLATE
10 SWITCHING POWER SUPPLY
11 NB-BAT MODULE, BATTERY CHARGER CARD
12 WIRING BETWEEN NB-BAT MODULE AND PWB CARD
13 NB-BAT MODULE, BATTERIES
14 BATTERY CABLE CONNECTION
STANDARD AUTOMATION:
AUTOMATION WITH BATTERY:

7
4) PRELIMINARY CHECKS
Before installing the automation, verify the following requirements:
• The support structure of the automation should be rm, with no signicant deformation.
• The structure of the leaf must be rigid and strong.
• The leaf hinges must be adequate and in good condition.
• The length and weight of the leaf must be within the operating limits of the automation.
• The movement of the leaf must be smooth and free of friction throughout the run.
• The door requires mechanical stops, consisting of a mechanical stop in open position and a nal stop in closed position.
The mechanical opening stop is not supplied with the automation.
In case the wall on which the automation is to be installed were not strong and reliable enough, you can purchase a pre-drilled
metal plate to which you can fasten the Neptis Plus automation.
There are two models of xing plates, FIXPLATE for the Neptis Plus automation without battery and FIXPLATE-P for the
Neptis Plus automation with built-in battery.
Soluzione/Solution
Braccio a slitta a tirare/Slide pull arm
Base Operator Neptis
FIXPLATE-P

8
730
(standard)
546
A = STANDARD TAPERED PIN
Should it be necessary to increase the distance between the automation and the arm (dimension X), replace the standard tapered pin
with the following optional extensions:
B = EXTB-Z TAPERED PIN (optional) for mm. 24 shaft extension
C = EXTC-Z EXTENSION (optional) for TAPERED PIN for mm. 48 shaft extension
ONLY FOR SPRING MODELS NB-LET / LETB / SLT / SLTB
For this application, please consider that the gearmotor must be on the hinged
side of the door for a correct opening movement direction.
5.1) ASSEMBLY OF THE AUTOMATION ON THE TRANSOM FROM THE HINGE SIDE
SLIDE PULL ARM BDT2
For doors opening inward (as seen from the automation side)
Automation with battery module
Standard Automation CABLE
PASSAGE SLOT CABLE
PASSAGE SLOT
5) TECHNICAL DRAWINGS
OPENING
DIRECTION
NB-SLT/SLTB/SMT/SMTB CHART NB-LET/LETB CHART
Usable leaf length and weight
Usable leaf length and weight with dierent
fastening dimensions
Installation drawings available upon request
Unusable leaf length and weight

9
730
546
5.2) ASSEMBLY OF THE AUTOMATION ON THE TRANSOM FROM THE HINGE SIDE
SLIDE PULL ARM BDT2R55
For doors opening inward (as seen from the automation side)
ONLY FOR SPRING MODELS NB-LET / LETB / SLT / SLTB
For this application, please consider that the gearmotor must be on the hinged
side of the door for a correct opening movement direction.
Usable leaf length and weight
Usable leaf length and weight with dierent
fastening dimensions
Installation drawings available upon request
Unusable leaf length and weight
Automation with battery module
Standard Automation CABLE
PASSAGE
SLOT CABLE
PASSAGE
SLOT
OPENING
DIRECTION
NB-SLT/SLTB/SMT/SMTB CHART NB-LET/LETB CHART

10
730
546
4
(standard)
A
X=51.5 mm
B
X=75.5 mm
A+C
X=99.5 mm
B+C
X=123.5 mm
A = STANDARD TAPERED PIN
Should it be necessary to increase the distance between the automation and the arm (dimension X), replace the standard tapered
pin with the following optional extensions:
5.3) ASSEMBLY OF THE AUTOMATION ON THE TRANSOM FROM THE HINGE SIDE
ELBOW ARM BSG 150/250
For doors opening inward (as seen from the automation side)
ONLY FOR SPRING MODELS
NB-LET / LETB / SLT / SLTB
For this application, please consider that the gearmotor
must be on the hinged side of the door for a correct
opening movement direction.
Automation with battery module
Standard Automation CABLE
PASSAGE
SLOT CABLE
PASSAGE
SLOT
OPENING
DIRECTION
B = EXTB-Z TAPERED PIN (optional) for mm. 24 shaft extension
C = EXTC-Z EXTENSION (optional) for TAPERED PIN for mm. 48 shaft
extension
NB-SLT/SLTB/SMT/SMTB CHART NB-LET/LETB CHART
Usable leaf length and weight
Usable leaf length and weight with dierent
fastening dimensions
Installation drawings available upon request
Unusable leaf length and weight
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali Label Sistema di apertura della porta

Label
Label ETERNA 90 EASY Manuale utente

Label
Label Neptis SLT-B Manuale utente

Label
Label NEXT 75 Manuale utente

Label
Label NEXT 120s Manuale utente

Label
Label NEPTIS/LE Manuale utente

Label
Label EVOLUS Manuale

Label
Label Neptis SMP Manuale utente

Label
Label T-NFC Manuale utente

Label
Label ETERNA 70 Manuale utente

Label
Label Neptis SMP Manuale utente