Lacanche Classic Manuale utente

Unit 3 Albion Close, Newtown Business Park, Poole Dorset.
BH12 3LL Tel: 01202 733 011 Fax: 01202733499
Email [email protected] Web www.fdef.co.uk
For Lacanche Classic & Modern Cluny
IMPORTANT INFORMATION FOR CUSTOMERS TO READ
Please read before delivery/installation of your cooker
Thank you for purchasing a Lacanche Cooker. To ensure that delivery/installation of your
cooker runs smoothly it is essential that you read the following carefully and adhere to all
specifications.
Please feel free to contact us regarding any aspect of the purchase of your Lacanche cooker.
The sales office telephone number is 01202 733011.
Type of Gas
Please check that the gas supply required (Natural/LPG) is correctly stated on our Order
Acknowledgement.
In the UK
In the UK the cooker must be installed by a Gas Safe registered engineer.
A suitable diameter copper pipe is required to supply the appliance with a constant 20
millibars of natural or 37 millibars of propane gas. The last metre of the copper pipe should
step to a 15mm diameter. The gas pipe should terminate with a plug-in female bayonet
pointing downwards. Although a 900mm hose can be used, a 1250mm hose will allow slightly
more flexibility in the positioning of the bayonet and make moving the cooker easier. The
hose should be fitted so that both inlet and outlet connections are vertical, so that the hose
hangs downwards in a ‘U’ shape.
For Natural Gas the flexible hose must be in accordance with B.S.669.
For LP Gas it should be capable of 50mbar pressure, 70C temperature rise and carry a red
stripe, band or label. If in doubt contact your supplier.
Safety Requirements and Regulations
This cooker must be installed in accordance with the relevant instructions in the Lacanche
Manual, with the relevant national and local regulations, and with the local gas and electricity
supply companies’ requirements.
Before installation, make sure that the cooker is suitable for your gas type and supply voltage.
See the data badge on range
The appliance must be installed in accordance with the regulations in force and only in a well-
ventilated space.
Read the instructions before installing or using this appliance.
In your own interest and that of safety, it is law that all gas appliances be installed by
competent persons.
Failure to install the appliance correctly could invalidate any warranty or liability claims and
lead to prosecution.
In the UK the cooker must be installed in accordance with:
• All relevant British Standards / Codes of Practice, in particular BS 5440 Part 2.
• For Natural Gas – BS 6172 and BS 6891.
• For LP Gas – BS 5482-1 (when the installation is in a permanent dwelling), BS 5482-2 (when
the installation is in a caravan or other non- permanent dwelling), or BS 5482-3 (when the
installation is in a boat).
• The Gas Safety (Installation and Use) regulations.
• The relevant Building / IEE regulations.

Unit 3 Albion Close, Newtown Business Park, Poole Dorset.
BH12 3LL Tel: 01202 733 011 Fax: 01202733499
Email [email protected] Web www.fdef.co.uk
Ventilation Requirements
The room containing the cooker should have an air supply in accordance with BS 5440 Part
2: 2000. All rooms require an openable window or equivalent, while some rooms
require a permanent vent in addition to the openable window. The cooker should not be
installed in a bedsitting room with volume less than 20m3. If it is installed in a room of
volume less than 5m3 an air vent of effective area 100cm2 is required; if it is installed in
a room of volume between 5m3 and 10m3, an air vent of effective area 50cm2 is required;
while if the volume exceeds 11m3, no air vent is required. If there are other fuels burning
appliances in the same room, BS 5440 Part 2: 2000 should be consulted to determine
the requisite air vent requirements.
Electrical Connections
This appliance must be installed by a qualified electrician to comply with the relevant
regulations and the local electricity supply company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED
Electrical Connections
The electrical connection point must be within 1 metre of the appliance. The root of the wire
connection must be such that the cable is not subjected to extremes of temperature or
mechanical damage. There must be a double pole isolation switch, which must be easily
accessible for the user and not placed behind the appliance. The correct rate of fuse must be
fitted at the consumer unit.
The electrical connections required are ticked below:
Cluny
Model
Total
Electrical
Load kW
13 amp
dedicated
electric
supply,
cable
size
2.5mm
20 amp
dedicated
electric
supply,
cable
size 6mm
32 amp
dedicated
electric
supply,
cable size
6mm
50 amp
dedicated
electric
supply,
cable
size
10mm
2 x twin
30 amp
dedicated
supply,
cable
size 6mm
per
supply
LG1052GE
2.2
✓
LG1052E
4.2
✓
LG1052GCT
2.65
✓
LG1052ECT
4.85
✓
LG1052CT
5.3
✓
LCF1052GE
2.2
✓
LCF1052E
4.2
✓
LCF1052GCT
2.65
✓
LCF1052ECT
4.85
✓
LVI1052EE
15.5
✓
LVI1052ECT
15.95
✓
LVI1052CT
16.4
✓

Unit 3 Albion Close, Newtown Business Park, Poole Dorset.
BH12 3LL Tel: 01202 733 011 Fax: 01202733499
Email [email protected] Web www.fdef.co.uk
Building in Instructions
A. The stainless-steel hob of the appliance should not be lower than the adjoining
worktops. The worktops can butt up to the hob.
B. Above the level of hob top surface of the appliance, there must be a minimum
lateral clearance of 75mm between the edge of the appliance and any adjacent
surface. This minimum clearance may be reduced to 50mm when the surfaces
are made of a fireproof material (ceramics, glass, stone, metal).
C. There must be a minimum vertical clearance of 800 mm between the top
surface of the appliance and any horizontal surface above.
D. When the appliance is being built into a run of units, inglenook or a chimney
a gap of 5mm must be maintained either side of the appliance.
E. Lacanche range cookers are designed to sit proud of the adjacent units. Units
adjacent to the cooker should not sit flush or proud of the cooker doors (including
oven, simmer oven and cupboard doors), but should sit flush with the main body of the
cooker, for side opening cupboard or simmer oven doors to open wide enough to insert
or remove shelves.
F. If the furniture next to the range is deeper than 595mm, the cooker will need to be
moved forward. The gap at the rear of the cooker can be filled by using the Lacanche
island spacer which is 70mm deep.
G. The above dimensions must be adhered to. Fourneaux de France Ltd is not responsible
for degradation of paintwork or material adjoining the cooker.

Unit 3 Albion Close, Newtown Business Park, Poole Dorset.
BH12 3LL Tel: 01202 733 011 Fax: 01202733499
Email [email protected] Web www.fdef.co.uk
Important Delivery Details
Please inspect your cooker at the time of delivery. If the appliance is received damaged,
please sign the delivery docket as damaged and report to Fourneaux de France Ltd within 24
hours of the day of delivery. Fourneaux de France Ltd will accept no claims for damage unless
the above procedure is followed.
Do not lift the cooker by the hand rail as this will result in damage to the control
panel which will not be covered by the manufactures warranty
Old appliances and packaging will not be removed.
Deliveries are on an anytime during the day basis from 8.00am to 8.00pm.
Door widths must be a minimum of 750mm. Please advise us if there are any obstructions or
hindrances, e.g. steps to basements, narrow passages or if the delivery is not to a ground
floor.
Warranty
Your Lacanche cooker has a 3-year electro mechanical parts and labour warranty. This
warranty is subject to the following provision. The warranty does not cover: accidental
damage, misuse, neglect, incorrect installation, enamelled inner or outer panels, pan stands,
oven cavity parts, brass burners, burner bodies, door seals, brass/chrome or other trims.
The product must be correctly installed, commissioned and operated in accordance with the
instructions in the User’s Manual. It must be used solely for domestic purposes, and within the
boundaries of the United Kingdom. The warranty will be rendered invalid if the product is
resold or has been damaged by inexpert repair. Repairs due to the appliance being incorrectly
commissioned will not be covered by the warranty. We must point out at this stage that,
should you experience any problems that are directly attributable to faulty connection or poor
commissioning carried out by an engineer other than our own, they will not be covered by the
warranty and a call out charge will be made to rectify the problem.
Should you have any queries at all concerning this information or require any
further assistance, please do not hesitate to contact us or your local stockist

Unit 3 Albion Close, Newtown Business Park, Poole Dorset.
BH12 3LL Tel: 01202 733 011 Fax: 01202733499
Email [email protected] Web www.fdef.co.uk
Cluny with Gas Top
Cluny Classic Top Cluny Traditional Top

Unit 3 Albion Close, Newtown Business Park, Poole Dorset.
BH12 3LL Tel: 01202 733 011 Fax: 01202733499
Email [email protected] Web www.fdef.co.uk
Cluny Induction Range
Questo manuale è adatto per i seguenti modelli
13
Indice
Altri manuali Lacanche Fornello

Lacanche
Lacanche RULLY Guida utente

Lacanche
Lacanche Cluny 1000 Guida utente

Lacanche
Lacanche LAE 010 CKG Guida utente

Lacanche
Lacanche MACON Guida alla configurazione

Lacanche
Lacanche SULLY CHALONNAIS LG 1432 GE Guida utente

Lacanche
Lacanche LAE 020 I Manuale utente

Lacanche
Lacanche CLUNY Manuale utente

Lacanche
Lacanche CLUNY INDUCTION Manuale utente

Lacanche
Lacanche CITEAUX INDUCTIONLVI 1532 E / CT Manuale utente

Lacanche
Lacanche CORMATIN LG 731 G Manuale utente