BDA M610 TA03 / 2019-09 (GB)
2
GENERAL SYSTEM DESCRIPTION
The M610 TA03 (keypad) locking system is a locker lock with a motor-driven locking bolt intended for use in the
home and oce. This manual gives you informaon in order to install and operate the locking system correctly. Keep
the operang instrucons in an easily accessible place. Using the locking system in applicaons for which it is not
intended may result in irreparable damage to it and render any claims null and void.
Wording and graphics have been prepared for you with care. However, no liability will be assumed for any mistakes
that may have occurred. The scope of items included by the manufacturer in the system as well as technical speci-
caons are subject to change without noce.
These instrucons must not be reproduced in any way (print, photocopy, etc.) either in whole or in part without
wrien consent from LEHMANN Vertriebsgesellscha mbH & Co. KG.
IMPORTANT: Only install the locking system when it is unlocked. For the correct mechanical connecon
of the locking system to your locker, please refer to the installaon instrucons of your locker
manufacturer. Perform all programming operaons and funconal checks when the locker
door is open. In the event of a malfuncon, you thus have access to all system components.
OPERATING DESCRIPTION
The M610 TA03 electronic locking system provides you with a convenient means of locking and unlocking your locker
electronically. The system has two operang modes.
Operang mode 1: Free Code
The user selects his own individual code (3 to 10 digits) for opening and closing the lock. In this mode, the code
memory is deleted again as soon as the user opens his locker. This means that the next user can select his new
individual code.
Operang mode 2: Fixed Code
The user can only open and close the lock with a xed preset code (3 to 10 digits).