Lenz DIGITAL plus LZ100 Manuale tecnico

1
Info Version 3.6
for LZ/LZV100 and LH100
04 08

2 Update LZ100 / LZV100 and LH100 to Version 3.6
1 New and changed features in version 3.6
Here is an overview of the new or changed features:
•Fast change between up to 12 freely selectable locomotive
addresses with the 'Esc' key.
•Functions F0 to F28 can now be switched.
•Functions F1 to F28 can be set to temporary or continuous
operation. This setting can be made individually for each
locomotive address. Ex-works, functions are set to continuous
operation.
•You can set which function information is to be stored in the
command station even when it is turned off. Ex-works,
functions F0 to F8 are stored.
•Function information stored in the command station is
transmitted cyclically via the track.
•The storage and cyclic transmission of information for
functions F5 to F28 can be activated and deactivated (only
LH100).
•Programming on the programming track from CV1 to CV1024.
•Programming in operational mode (PoM) from CV1 to
CV1024.
•Simple increasing and decreasing of CV values during
programming: Ideal, for example, for setting the maximum
speed of a locomotive (only LH100).
•Simple change to the next or previous CV during
programming (only LH100).
•Reading of CVs via PoM with the RailCom address display
LRC120.

Changes to the LH100 3
2 Changes to the LH100
Due to the new functions we have made some changes to the display
and operation of the LH100. These changes are described below.
2.1 Display when controlling a locomotive
12345678
Figure 9 indicates whether function 9 o
f
the newly selected function group is
activated or not.
The lamp symbol indicates whethe
r
function 0 of the newly selected function
group is activated or not.
The arrow indicates the direction of motion:
A
rrow upward: forward
A
rrow downward: backward
Lines indicate the function groups:
1 vertical line:
Function group 1 (F0 to F9)
2 vertical lines:
Function group 2 (F10 to 19)
3 vertical lines:
Function group 3 (F20 to F28)
This field indicates the address o
f
- a single locomotive (L),
- a locomotive in multiple traction operation (m),
- a double traction (D),
- a multiple traction (M) o
r
- the speed step (V)
Figures 1 to 8 indicate whethe
r
functions 1 to 8 of the newly selected
function group are activated or not.

4 Update LZ100 / LZV100 and LH100 to Version 3.6
2.1.1 Examples for the most important displays:
13 8
The single locomotive (L) with address
0003 is controlled.
The display of function group 1 is
selected; functions 0, 1, 3 and 8 are
activated.
34 8
The locomotive with address 1234 is in
multiple-traction operation (m).
The display of function group 2 is
selected; functions 10, 19, 13, 14 and 18
are activated.
The multiple traction with address 0033 is
controlled.
When the multiple-traction address is
displayed, no functions are displayed.
2.2 The expanded stack
Up to version 3 it was possible to change between two locomotive
addresses with the 'Esc' key of the LH100. With version 3.6 it is now
possible to scroll through a stack of up to 12 locomotive addresses
with the 'Esc' key. This is comparable to an index card box with 12
index cards. You can place any locomotive address in any stack slot.
Ex-works, locomotive addresses 1 to 12 are placed in this stack.
2.2.1 Scrolling through the stack
Each time the LH100 is turned on,
stack slot 1 is displayed. Ex-works,
this slot is occupied by locomotive
address 1.
Press 'Esc' to display the next stack
slot.

Changes to the LH100 5
Release 'Esc' to display the
locomotive address placed in this
slot.
Press 'Esc' again to change to the
next stack slot …
... and to display the locomotive
address placed in this slot.
. . .
Continue until the last stack slot is
displayed.
After the last stack slot, the first slot
will be displayed again …
... with the locomotive address placed
therein.
You can scroll through the stack only in forward direction.
2.2.2 Setting the stack size
Ex-works, the stack has 12 slots. The size can be set from 1 to 12.
To change the number of stack slots,
go to the 'SYS' menu:
The menu that was selected last is
displayed.

6 Update LZ100 / LZV100 and LH100 to Version 3.6
Select 'SYS'.
Select 'Setup'.
The current stack size is displayed.
Decrease the stack size with '-'.
Decrease the stack size with '-'.
Increase the stack size with '+'.
Confirm your selection.
Return to the 'SYS' menu.
Return to displaying the locomotive
address.
Locomotive addresses are set as with the last version.
2.3 Switching locomotive functions
As in previous versions of the LH100, locomotive decoder functions
can be activated and deactivated with keys 0 to 9 while controlling the
locomotive.
Depending on the selected function group (1 to 3), the following
functions are switched:

Changes to the LH100 7
Key:
Function group 1: 0 1 2 3 4 5 6 7 8 9
Function group 2: 10 11 12 13 14 15 16 17 18 19
Function group 3 20 21 22 23 24 25 26 27 28
The bottom line of the display shows the function status: If the function
number is visible, the function is activated; if the number is not visible,
the function is deactivated.
2.4 Changing function groups
Up to three vertical lines to the left of the display of the locomotive
address indicate the selected function group.
Press this key to change to the next function group.
Press this key to change to the previous function group.
Exception: A multiple-traction address (M) or the address of a
locomotive in multiple-traction operation (m) is displayed. In this case,
use the '-' key to scroll through the addresses of the locomotives in
multiple-traction operation.
13 8
Function group 1 is displayed;
functions 0, 1, 3 and 8 are activated.
257
3
Function group 2 is displayed;
functions 12, 13, 15, 17 and 19 are
activated.
2
18
Function group 3 is displayed;
functions 20, 21, 22 and 28 are
activated.
13 8
Displays function group 1 again.

8 Update LZ100 / LZV100 and LH100 to Version 3.6
2.5 Configuring locomotive decoder functions
Functions F1 to F12 of the locomotive decoder can be set to
continuous or temporary operation.
Continuous operation Temporary operation
Press the key to activate the
function; press the key again to
deactivate it.
Press the key to activate the
function; release the key to
deactivate it.
This information is stored in the command station LZ100/LZV100.
When calling the locomotive, the manual control queries the setting
from the LZ100/LZV100. This setting can be made individually for
each function and each locomotive address.
Proceed as follows:
13 8
Select the address of the locomotive
whose function setting you want to
display or change.
The menu that was selected
last is displayed.
23 78
The configuration of function group 1
(functions 0 to 9) is displayed first.
The figures in the bottom line show the function settings:
Visible functions: Functions are set to continuous
operation (here 9, 2, 3, 7 and 8).
Invisible functions: Functions are set to temporary
operation (here 1, 4, 5 and 6).
To change the setting, simply press the number key corresponding to
the function.
14 8
Press '+' to change to the next
function group (group 2, F10 to F19).
The setting is made analogously to
group 1.
12 45 78
Press '+' again to change to function
group 3 (F20 to F28).
The setting is made analogously to
group 1.

Changes to the LH100 9
13 8
Press 'Enter' to complete the entering
process and store the new setting in
the command station. Press 'Esc' to
return to controlling the locomotive
without storing the setting.
2.6 'Refreshing' functions
By 'refreshing' functions we mean the following: In defined regular
intervals the command station sends function information via the track
to all decoders located on the track. This ensures that a decoder does
not 'forget' all settings, even if the connection between command
station and decoder is interrupted intentionally (due to 'dead frogs') or
unintentionally (due to dirt on the track or power interruptions).
For very large layouts with very many locomotives or decoders it may
make sense to deactivate the cyclic transmission of individual
functions to decrease the time delay resulting from the total time
required for each transmission (typically 8 mS).
This way, you can decide which function information is transmitted
cyclically and which not. Ex-works, the information of functions 0 to 8
is transmitted cyclically. 'Refreshing' affects all locomotive addresses.
To 'refresh' functions, proceed as follows:
13 8
Start with 'controlling the locomotive'.
It does not matter which locomotive
address you select.
The menu that was selected
last is displayed.
Functions F0 to F8 are transmitted
cyclically.
Use '+' to scroll through the options:
Functions F0 to F12 are transmitted
cyclically.

10 Update LZ100 / LZV100 and LH100 to Version 3.6
Functions F0 to F20 are transmitted
cyclically.
Functions F0 to F28 are transmitted
cyclically.
Functions F0 to F4 are transmitted
cyclically.
13 8
Press 'Enter' to confirm your
selection.
2.7 Displaying and changing the speed-step mode
To display or change the speed-step mode, proceed as follows:
13 8
Select the address of the locomotive
whose speed-step mode you want to
display or change. Make sure that the
locomotive is set to speed step 0 (if
not, press the hexagonal key).
The menu that was selected
last is displayed.
Press '+' to display the speed-step
mode currently set.
Press '+' again to display the speed
steps available:
Altri manuali per DIGITAL plus LZ100
1
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Lenz Controllori

Lenz
Lenz Digital Plus LH100 Manuale

Lenz
Lenz DIGITAL plus LZ100 Manuale del proprietario

Lenz
Lenz Digital plux LH101-R Manuale utente

Lenz
Lenz Digital plus LH101 Manuale utente

Lenz
Lenz PositionServo 940 Manuale utente

Lenz
Lenz digital plus lh01 Manuale

Lenz
Lenz Digital plus Set-01 Manuale utente

Lenz
Lenz Digital plus LH101 Manuale utente

Lenz
Lenz Digital plus LH101 Manuale utente