LG V-net PQNUD1S00 Guida rapida

ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH CHINESE
LG
Power Distribution
Indicator
LG
IMPORTANT
• Please read this user's manual completely
before installing the product.
• Installation work must be performed in
accordance with the national wiring standards
by authorized personnel only.
• Please retain this user's manual for future
reference after reading it thoroughly.
Models: PQNUD1S00
OWNER'S & INSTALLATION MANUAL
Visit us at : http://www.lgservice.com

2Electricity Distribution Indicator
Power Distribution Indicator Owner's & Installation Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
■Staple your receipt to this page in the event you need
to prove date of purchase or to issue warranty.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your Power Distribution Indicator properly.
Just a little preventive care on your part can save you a
great deal of time and money over the life of your
Power Distribution Indicator.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
•Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
• Installation work must be performed in accordance with
the National Electric Code by qualified and authorized
personnel only.
Cautions for safety ......................3
Overview ......................................6
Available Watt-hour meter ..........7
Wiring Diagram ..........................10
Installation ..................................11
How to set interface unit ...........17
How to set each Indoor Unit
for Multi V ...................................18
Installation Guide.......................20
Usage .........................................21

Cautions for safety
User’s Manual 3
ENGLISH
You should always request
product installation to our
Service Center or to
installation expert agency.
Use specified parts.
When reinstalling an existing
installed product, request it to
our Service Center or to
installation expert agency.
• Otherwise it may cause
fire hazard, electric shock,
explosion, injury or
damage.
• Or else it may cause fire
hazard, electric shock,
explosion, injury, damage
and trouble failure.
• Otherwise it may cause fire
hazard, electric shock,
explosion, injury or damage.
Don’t keep or use ignitable gas or any other
flammable material in vicinity of the product.
Don’t disassemble, repair and modify the
product at your will.
• Otherwise it may cause fire hazard and
product trouble failure.
• Or else it may cause fire hazard and electric
shock.
Cautions for safety
To prevent injury to the user or other people and property damage, the following instructions must be
followed.
■Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
■Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
■WHEN INSTALLING
SPECIFIED
PA R T S
Benzene
Ether Thinner

Cautions for safety
4Electricity Distribution Indicator
Don’t install it where rain falls on. Don’t install it in humid place.
• Otherwise it may cause product failure. • Otherwise it may cause product failure.
Don’t change or extend
electric supply wire at your
will.
Don’t let there exist fire heat
near the product.
Don’t use heat equipment
near the electricity supply
line.
• Or else it may cause fire
hazard and electric shock.
• Otherwise it may cause fire
hazard.
• Or else it may cause fire
hazard and electric shock.
Don’t spill water into interior
of the product.
Don’t put heavy material upon
electricity supply chord.
Don’t put heavy material
upon the product.
• Otherwise it may cause
electric shock and product
failure.
• Or else it may cause fire
hazard and electric shock.
• Or else it may cause
product trouble failure.
Always request to our Service
Center or installation expert agency
in such case as the product has
been submerged under water.
Child or the old and the weak
shall use it under custody of
patron.
Don’t give impact to the
product.
• Or else it may cause fire
hazard and electric shock.
• Otherwise it may cause
safety accident or product
failure.
• If the product is impacted,
it may cause product
trouble failure.
■WHEN USING

Cautions for safety
User’s Manual 5
ENGLISH
Don’t clean the product with
strong detergent of solvents
but only use soft cloth.
If water has been smeared
on electric charge part, use
it after removing water.
Don’t let metallic products
of necklace, coin, key, watch
etc. touch the battery
terminal.
• Or else it may cause fire
hazard and product
deformation.
• Or else it may cause
product failure.
• Or else it may cause product
failure and injury.
■WHEN USING
Wax
Thinner

Overview
Overview
6Electricity Distribution Indicator
■Functions
• Accumulation of total power consumption
• Indication of current power in use
• Indication of accumulated power for period
• Indication of standby power (option setting)
■Specification
• Power Supply: 220~240V AC 50/60HZ 1Ø
• Dimension: 200mm (W) X 120mm (H) X 55mm (D)
• Connectable Units: 1 Outdoor Unit per Electric Power Distribution Indicator.
■Count Method for Electric Power Distribution
• Power Consumption of each Indoor Unit = Power Consumption of Outdoor Unit x [Weighting Power of each
Indoor Unit / Weighting Power of total Indoor Units]
• Weighting Power of each Indoor Unit = Operation (On/Off) x [ Capacity of Indoor Unit X LEV open rate X Fan
step of Indoor Unit ]

Overview
User’s Manual 7
ENGLISH
1. Indicator LCD Display
2. Name Plate of each room
3. Menu Button
4. Up and Down Button
5. Right Shift Button
6. SHIFT Button for LCD Screen Change
Available Watt-hour meter(Local purchase)
1
2
3
4
5
6
■Parts of a PDI
• Use the digital watt meter which send the pulse signal depending on the power consumption.
• Use watt meter of 1W/pulse, 2W/pulse, 4W/pulse, 6W/pulse, 8W/pulse or 10W/pulse
(pulse width: 40 –400 msec).

Wiring Diagram
8Electricity Distribution Indicator
Pulse type
PDI 1Ø
220VAC
Multi V Outdoor unit
Multi V Outdoor unit
Indoor unit address setup
(00) (01) (02) (03)
Watt meter
3Ø 380VAC or
1Ø 220VAC
Pulse type
PDI 1Ø
220VAC
Indoor unit address setup
(00) (01) (02) (03)
PI-485
Watt meter
3Ø 380VAC or
1Ø 220VAC
0 0 0 0 0 0 0 0 M a s t e r 1 W / p
M I C R O N I C N O - S T B P
In this case, please set the product "Unit" [00]
1 1 0 0 0 0 0 0 M a s t e r 1 W / p
M I C R O N I C N O - S T B P
In this case, please set the product "Master"[11]
■Independent operation of PDI
- Connect the product as shown in the below connection diagram
1. Multi V (1Outdoor with less than 16 Indoors)
2. Multi V (In case of setting more than 16 Indoors) or Multi
Wiring Diagram
❈NOTE : In connecting MPS product
PI-485 must be connected for PDI. (PI-485 must be purchased separately.)

Wiring Diagram
User’s Manual 9
ENGLISH
■Operation with PC Central controller
- Connect the product as shown in the below connection diagram.
PDI
PDI
Multi/ Multi V Outdoor unit
Multi/ Multi V Outdoor unit
G/W(PNF-G14B0)
Indoor unit
address setup
Indoor unit
address setup
PI-485
PI-485
Watt meter
Watt meter
3Ø380VAC or
1Ø220VAC
PC central controller
with PDI.
(00) (01) (02) (03)
(7C) (7D) (7E) (7F)
1 0 0 0 0 0 0 0 M a s t e r 1 W / p
M I C R O N I C N O - S T B P
In this case, please set the
product "Slave"[10]
1 0 0 0 0 0 0 0 M a s t e r 1 W / p
M I C R O N I C N O - S T B P
In this case, please set the
product "Slave"[10]
When CNU power off or out of order with PC central controller, the PDI can not distribute the power
consumption.
❈NOTE : PI-485 must be connected for PDI.
(PI-485 must be purchased separately.)

Internal Wiring Diagram
10 Electricity Distribution Indicator
WHMPDI
Multi / Multi V
Outdoor unit
PI-485
...
Indoor unit
PI-485 communications A/B or
MultV/MultiV PLUS A/B
[ B->B / A->A ]
CN-POWER
220~240VAC
1P, 50/60Hz Watt meter
WHITE BLACK
BA
CN-WATTMETER
CN_OUT FAN
The color and polarity of the communications line can differ
from what’s indicated on the PCB depending on the
manufacturer of watt meter. [ Black -> (+), white -> (-) ]
•Turn on the power after connecting the product.
■Install the product as per the following wiring diagram
Internal Wiring Diagram
Altri manuali per V-net PQNUD1S00
3
Indice
Lingue: