LG LSRG309ST Manuale utente

ENGLISH
INSTALLATION MANUAL
GAS RANGE
Please read this guide thoroughly before installation.
LSRG309ST
P/No.: MFL62177702www.lg.com
ENGLISH ESPAÑOL

2
INSTALLATION INSTRUCTIONS
INSTALLATION SAFETY INSTRUCTIONS
BEFORE YOU BEGIN
Remove all tape and packing materials before using the range. Dispose all plastic bags after
unpacking the range. Never allow children to play with packing materials.
IMPORTANT SAFETY INSTRUCTIONS
Read these instructions completely and carefully. Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage. Refer to this manual. or assistance or
additional information, consult a qualified installer, service agency, manufacturer (dealer) or the gas
supplier.
This symbol will alert you to hazards or unsafe practices which could
cause serious bodily harm or death.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or
hurt you and others. All safety messages will follow the safety alert symbol and either the
word “WARNING” or “CAUTION”.
This symbol will alert you to hazards or unsafe practices which could
cause bodily injury or property damage.
WARNING
CAUTION
READ ALL INSTRUCTIONS BEFORE INSTALLATION
WHAT TO DO IF YOU SMELL GAS
•
DO NOT
try to light any appliance.
•
DO NOT
touch any electrical switch.
•
DO NOT
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. ollow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
– DO NOT store or use combustible materials,
gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier
WARNING:
If the information in
this manual is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.

ENGLISH
3
INSTALLATION INSTRUCTIONS
• NEVER reuse old flexible connectors. The use of
old flexible connectors can cause gas leaks and
personal injury. Always use NEW flexible
connectors when installing a gas appliance.
• Your range must be installed by a qualified
installer.
• Your range should be electrically grounded in
accordance with local codes or, in the absence of
local codes, in accordance with the National
Electrical Code (ANSI/N PA 70, latest edition). In
Canada, electrical grounding must comply with
the current CSA C22.1 Canadian Electrical Code
Part 1 and/or local codes. See “ELECTRICAL
CONNECTIONS” in this manual.
• Before installing your range on linoleum or any
other synthetic floor covering, make sure the floor
covering can resist 180° (82°C) without shrinking,
warping or discoloring. Do not install the range
over carpeting unless a sheet of 1/4” thick
plywood or similar insulator is placed between the
range and carpeting.
• Make sure the wall coverings around the range
can resist heat generated by the range up to
180° (93°C).
• Leak testing of the appliance shall be conducted
according to the manufacturer’s instructions.
• Avoid placing cabinets above the range. To
minimize the hazard caused by reaching over the
open flames of operating burners, install a
ventilation hood over the range that projects
forward at least 5” beyond the front of the
cabinets.
• The ventilation hood must be constructed of sheet
metal not less than 0.0122” thick. Install above
the cooktop with a clearance of not less than 1/4”
between the hood and the underside of the
combustible material or metal cabinet.
The hood must be at least as wide as the
appliance and centered over the appliance.
Clearance between the cooking surface and
the ventilation hood surface MUST NEVER BE
LESS THAN 24 INCHES.
EXCEPTION: Installation of a listed microwave
oven or cooking appliance over the cooktop shall
conform to the installation instructions packed with
that appliance.
• If cabinets are placed above the range, allow a
minimum clearance of 30
”
between the cooking
surface and the bottom of unprotected cabinets.
INSTALLATION SAFETY INSTRUCTIONS (continued)
READ ALL INSTRUCTIONS BEFORE INSTALLATION
WARNING
• DO NOT step or sit on the door. Install the
Anti-Tip Bracket packed with range.
- The range could be tipped and injury might result
from spilled hot liquid, food, or the range itself.
- If the range is pulled away from the wall for
cleaning, service, or any other reason, ensure that
the Anti-Tip Device is properly reengaged when
the range is pushed back against the wall.
All ranges can tip and injury could result. To prevent
accidental tipping of the range, attach an approved
Anti-Tip device to the wall. (See “INSTALLING THE
ANTI-TIP DEVICE” in this manual.) To check if the
device is installed and engaged properly, carefully
tip the range forward. The Anti-Tip device should
engage and prevent the range from tipping over.
If you pull the range out from the wall for any
reason, make sure the Anti-Tip device is engaged
when you push the range back against the wall.
WARNING!
• ALL RANGES CAN TIP
• INJURY TO PERSONS
COULD RESULT
• INSTALL ANTI-TIP DEVICES
PACKED WITH RANGE
• SEE INSTALLATION

INSTALLATION INSTRUCTIONS
44
READ ALL INSTRUCTIONS BEFORE INSTALLATION
PREPARING FOR INSTALLATION
TOOLS YOU WILL NEED MATERIALS YOU MAY NEED
• Gas line shut-off valve
• Pipe joint sealant that resists action of natural and
LP gases.
• lexible metal appliance connector (3/4” or 1/2” NPT
x 1/2” I.D.)
Never use an old connector when installing a new
range.
• lare union adapter for connection to gas supply line
(3/4” or 1/2” NPT x 1/2” I.D.)
• lare union adapter for connection to pressure
regulator on range (1/2” NPT x 1/2” I.D.)
• Liquid leak detector or soapy water.
• Lag bolt or 1/2” O.D. sleeve anchor (for concrete
floors only).
IN THE COMMONWEALTH OF MASSACHUSETTS
• This product must be installed by a licensed
plumber or gas fitter.
• When using ball type gas shut-off valves, they shall
be the T-handle type.
• When using a flexible gas connector, it must not
exceed 3 feet in length.
Phillips screwdriver
Flat-blade screwdriver
Pencil and ruler Pipe wrench(2)
(one for support)
Open-end or
adjustable wrench
Level
INSTALLATION SAFETY INSTRUCTIONS (continued)
• Items of interest to children should not be stored in
cabinets above a range or on the backsplash of a
range—children climbing on the range to reach
items could be seriously injured.
• DO NOT attempt to operate the oven of this range
during a power failure.
CAUTION
WARNING
• If a 30” clearance between cooking surface and
overhead combustible material or metal cabinets
cannot be maintained, protect the underside of the
cabinets above the cooktop with not less than 1/4”
insulating millboard covered with sheet metal not
less than 0.0122” thick. Clearance between the
cooking surface and protected cabinets MUST
NEVER BE LESS THAN 24 INCHES.
• The vertical distance from the plane of the cooking
surface to the bottom of adjacent overhead
cabinets extending closer than 1” to the plane of
the range sides must not be less than 18”. (See
the Dimensions and Clearances illustration in this
manual.)

5
INSTALLATION INSTRUCTIONS
ENGLISH
DIMENSIONS AND CLEARANCES
Provide proper clearances between the range and
adjacent combustible surfaces. These dimensions
must be met for safe use of your range. The location
of the electrical outlet and pipe opening (see “GAS
PIPE AND ELECTRICAL OUTLET LOCATIONS”)
may be adjusted to meet specific requirements.
The range may be placed with 0” clearance (flush) at
the back wall.
INSTALLATION
CLEARANCES
Minimum to
cabinets on
either side of
the range
18”
5”
30”
30”
5”
36” 1/4”
13”
0”
DIMENSIONS
Height
Depth with door open.
Depth with door closed (includes door handle)
Minimum
clearance
to left wall
Minimum clearance to
right wall
Front edge of
the range side
panel forward
from cabinet
To cabinets
below cooktop
and at the range
back
Maximum depth
for cabinets
above
coutertops
Minimum
30”
283/4”
477/16”
471/4”
36” ±1/4”

6
INSTALLATION INSTRUCTIONS
LOCATION
Do not locate your range where it may be subject
to strong drafts. Any openings in the floor or wall
behind the range should be sealed. Make sure the
openings around the base of the range that
supply fresh air for combustion and ventilation
are not blocked by carpeting or woodwork.
Your range, like many other household units, is heavy
and can be installed on soft floor coverings such as
cushioned vinyl or carpeting. Use care when moving
the range on this type of flooring.
It is recommended that the following simple and
inexpensive instructions be followed to protect your
floor.
When the floor covering ends at the front of the range
the area that the range will be installed on should be
built up with plywood to the same level or higher than
the floor covering. This will allow the range to be
moved for cleaning and servicing, as well as proper
air flow to the range.
Also, make sure the wall covering can resist 180°
(82°C). See the "INSTALLATION SA ETY
INSTRUCTIONS" (included in this manual).
Make sure the wall coverings around your range can
resist the heat generated (up to 200° /93°C) by the
range. See the "INSTALLATION SA ETY
INSTRUCTIONS" (included in this manual).

7
INSTALLATION INSTRUCTIONS
ENGLISH
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
1. PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure of
5” of water column on natural gas or 10” of water
column on LP.
Make sure you are supplying your range with the type
of gas for which it is configured.
This range is convertible for use on natural or LP gas.
When using this range on LP gas, conversion must be
made by a qualified LP installer before attempting to
operate the range.
or proper operation, the pressure of natural gas
supplied to the regulator must be between 5” and 13”
of water column.
or LP gas, the pressure supplied to the regulator
must be between 10” and 13” of water column.
When checking for correct operation of the regulator,
the inlet pressure must be at least 1” more than the
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the
range must remain in the supply line regardless of
which type of gas is being used.
A flexible metal appliance connector used to connect
the range to the gas supply line should have an I.D. of
5/8” and a max of 5ft. In Canada, flexible connectors
must be single wall metal connectors less than 6 feet
in length.
Recommended area for 120V
outlet on rear wall and area for
through-the wall connection of
pipe stub and shut-off valve.
Recommended area for
through-the floor connection
of pipe stub and shut-off valve.
15”
30”
2”
3”
181/3”
161/2”

8
INSTALLATION INSTRUCTIONS
FLEXIBLE CONNECTOR HOOKUP
Pressure regulator
Installer: Inform the
consumer of the
location of the gas
shut-off valve.
Adapter
Adapter
Gas shut-off valve
1/2” or 3/4”
Gas pipe
Flex connector
(6 ft. max.)
Gas Flow into Range
2. CONNECT THE RANGE TO GAS
Shut off the range gas supply valve before
removing the old range and leave it off until the
new hook-up has been completed.
Because hard piping restricts movement of the range,
the use of a CSA International-certified flexible metal
appliance connector should be used unless local
codes require a hard-piped connection.
NEVER reuse an old connector when installing a new
range.
To protect against gas leaks, use a qualified pipe joint
sealant on all external threads.
Install male 1/2” or 3/4” flare union adapter to the
NPT internal thread of the manual shut-off valve,
taking care to back-up the shut-off valve to keep it
from turning.
Install male 1/2” flare union adapter to the 1/2”
NPT internal thread at inlet of presure regulator.
Use a backup wrench on the presure regulator
fitting to prevent damage.
Connect flexible metal appliance connector to the
adapter on the range. Position range to permit
connection at the shut-off valve.
When all connections have been made, be sure
all range controls are in the off position and turn
on the main gas supply valve. Check for gas leaks
by using a liquid leak detector at all joints and
connections.
A
C
B
D
DO NOT USE A FLAME TO CHECK FOR GAS
LEAKS.
WARNING!
WARNING!
Isolate the range from the gas supply system by
closing its individual shut-off valve during any
pressure testing of the gas supply system at test
pressures equal to or less than 1/2” psig(3.5kPa).

9
INSTALLATION INSTRUCTIONS
ENGLISH
ELECTRICAL REQUIREMENTS
120 Volt, 60 Hertz, properly grounded dedicated circuit protected by a 15 or 20 Amp circuit breaker, or slow
blow fuse.
GROUNDING
IMPORTANT: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
3. ELECTRICAL CONNECTIONS
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the
possibility of electric shock hazard from this
appliance.
The customer should have the wall receptacle and
circuit checked by a qualified electrician to make sure
the receptacle is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG ROM
THE POWER CORD.
A word about G CI’s – G CI’s are not required or
recommended for gas range receptacles.
Ground ault Circuit Interrupters (G CI’s) are devices
that sense leakage of current in a circuit and
automatically switch off power when a threshold
leakage level is detected. These devices must be
manually reset by the consumer. The National
Electrical Code requires the use of G CI’s in kitchen
receptacles installed to serve countertop surfaces.
Performance of the range will not be affected if
operated on a G CI-protected circuit but occasional
nuisance can occur.
DO NOT use an adapter plug because disconnecting
of the power cord places undue strain on the adapter
and leads to eventual failure of the adapter ground
terminal.
The installation of appliances designed for mobile
home installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24
C R, Part 3280 (formerly the ederal Standard for
Mobile Home Construction and Safety, Title 24, HUD,
Part 280) or, when such standard is not applicable,
the Standard for Manufactured Home Installations,
latest edition (Manufactured Home Sites,
Communities and Set-Ups), ANSI A225.1, latest
edition, or with local codes. In Canada, mobile home
installation must be in accordance with the current
CAN/CSA Z240/MH Mobile Home Installation Code.
Ensure proper ground
exists before use
PREFERRED
METHOD
4. SEAL THE OPENINGS
Seal any openings in the wall and floor after electrical and gas supplies are completed.
CAUTION:
The customer should have the circuit checked by a
qualified electrician to make sure the receptacle is
properly grounded.

10
INSTALLATION INSTRUCTIONS
5. ASSEMBLE THE SURFACE BURNERS
CAUTION
Place the burner caps and heads on the cooktop.
Make sure that the caps and heads are placed in the
correct locations. There is one small, one medium,
one large and one extra large burner head and cap.
Make sure the hole in the burner head is positioned
over the electrode.
6. CHECK IGNITION OF SURFACE BURNERS
ELECTRIC IGNITION
Select a top burner knob and simultaneously push in
and turn to the “LITE” position. You will hear a clicking
sound indicating proper operation of the spark
module.
Once the air has been purged from the supply lines,
burner should ignite within 4 seconds.
After burner ignites, rotate knob out of the “LITE”
position. Try each burner in succession until all
burners have been checked.
QUALITY OF FLAMES
The combustion quality of burner flames needs to be
confirmed visually.
A Yellow flames—Call for service
B Yellow tips on outer cones—
It is normal for LP gas
C Soft blue flames—
It is normal for natural gas
With LP gas, some yellow tipping on outer cones is
normal.
Oval (Center) Burner
Head/Cap Assembly
Medium burner
head and cap
Large burner
head and cap Front of range
Small burner
head and cap
Extra large burner
head and cap
Hole
Electrode
DO NOT operate the burners without all parts in
place.
Altri manuali per LSRG309ST
7
Indice
Altri manuali LG Allineare

LG
LG LRE6383SB Manuale utente

LG
LG UPSG3014ST Manuale utente

LG
LG LRE30453ST Manuale per l'uso e la cura

LG
LG LSIS3018SS Manuale utente

LG
LG LSC5683WS Manuale utente

LG
LG LDG4315ST Manuale utente

LG
LG LSES6338F.BRSLSTD Manuale utente

LG
LG LRG4111ST Manuale utente

LG
LG LDG3011ST Manuale di istruzioni

LG
LG UPSE3024ST Manuale utente

LG
LG LRE30451ST Manuale per l'uso e la cura

LG
LG LRE4213ST Manuale utente

LG
LG LDG4315BD Manuale utente

LG
LG LDE4413ST Manuale utente

LG
LG LSEL6333 Series Manuale utente

LG
LG LDE3019ST Manuale utente

LG
LG LRFVS3006S Manuale utente

LG
LG LRE3193BD Manuale utente

LG
LG LTEL7337 Series Manuale utente

LG
LG LRG30855ST Manuale utente