Table of contents
1 - Intended Use1 - Intended Use
2 - Precautions2 - Precautions
3 - Contra Indication3 - Contra Indication
4 - Definition of parts4 - Definition of parts
5 - Validity5 - Validity
6 - Install your treadmill6 - Install your treadmill
7 - Maintenance7 - Maintenance
7.1 - Emergency stop installation
8 - Troubleshooting8 - Troubleshooting
8.1 - Belt alignment
9 - Cleaning9 - Cleaning
10 - Control with an External Device10 - Control with an External Device
11 - Control with the Lode Ergometry Manager (LEM)11 - Control with the Lode Ergometry Manager (LEM)
12 - List of symbols used12 - List of symbols used
13 - Electromagnetic Compatibility (EMC)13 - Electromagnetic Compatibility (EMC)
14 - Specification remarks14 - Specification remarks
15 - Accessories15 - Accessories
16 - Specifications16 - Specifications

1 - Intended Use
This device is intended to be used as a stress test device in a medical environment. The main goal of
the use of the devices is to create reproducible stress tests. With cycling ergometers typically workload
(watt) is imposed. With treadmills typically speed (km/h) and inclination (% grade) are imposed. This
product is designed both for manual operation and for control by external ECG-, pulmonary
equipment. Most likely this device will be used in conjunction with another medical device to obtain
other important physiological data, allowing a physician to evaluate a test subjects physical status.
The product may also be used for rehabilitation or active aging therapy.
As such the intended use of the device solely cannot be defined specifically.
The device has to be operated under the supervision of well-trained medical specialists in the field of
use.
The ultimate judgment whether a test subject should undertake a stress test with the device must be
made by the responsible medical specialist, based on the limitations of each individual, the medical
history and all other applicable circumstances. Neither the manufacturer nor its distributors assume
any responsibility for the final use of its equipment.
2 - Precautions
Read this manual before using the device and follow it
carefully.
The operator should instruct the test subject prior to
performing an exercise protocol. If, at any time during
exercise, the test subject feels faint, dizzy, or experiences
pain, stop the test and he or she should be consulted by the
physician.
Care should be taken in mounting or dismounting the
ergometer. Be aware of feet when replacing the ergometer.
The operator should not touch accessible parts and the
patient simultaneously.
3/21M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25

The test subject should always wear the belt of the lanyard
safety belt.
Replacement of the power supply cord should be installed by
authorised service personnel, instructions for correct
connection and anchoring must be ensured, securing that
the requirements of clause 8.11.3 of IEC 60601 1:2005 are
met.
Set up and operate the device on a solid level surface.
The test subject should not wear loose or dangling clothing
while using the device.
Service of this device is restricted to factory trained
personnel only.
Do not jump onto the rotating belt. Do not jump off the
rotating belt (not even to the front). Do not stop moving on
the running belt. Do not turn around on the running belt. Do
not move sideways or backwards. Do not make movement
that could get you out of balance.
The test subject shall wear clothes when using the harness or
the lanyard belt to prevent skin irritation.
Replacement of parts can only be done by the manufacturer
or designated service personnel.
4/21M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25

Read all warnings posted on the device.
Inspect the device for worn or loose components prior to
use. Tighten / replace any loose or worn components prior to
use.
Do not place any loose parts or objects on the device before
and during use.
The equipment has a safety earth (ground) connection and
must be connected to a (grounded) wall socket with
protective earth to avoid the risk of electric shock. The
functional earth connection is for potential equalisation only.
The operator must keep away from the footrail while
lowering.
The test subject should wear proper sports or running shoes
(no spikes).
If this equipment is modified, appropriate inspection and
testing must be conducted to ensure continued safe use of
the equipment.
Cleaning and user maintenance shall not be made by
children without supervision.
5/21M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25

Children being supervised are not to play with the appliance.
Children shall not play with the appliance.
Heart rate monitoring systems may be inaccurate. Over
exercise may result in serious injury or death. If the test
person feels faint stop exercising immediately.
Keep away from the rollers.
No modification of this equipment is allowed.
Not suitable for use in the presence of flammable
anaesthetics.
The appliance is not to be used by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge.
The test subject should wear proper sports clothing. The
operator should check possible entrapment of clothing,
fingers or feet, before the start of an exercise test.
6/21M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25

This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved.
This device should only be sold by, or under the supervision
of authorized persons.
Your device may be executed with heart rate measurement,
blood pressure measurement, and / or SpO2 (blood
saturation) measurement. These measurements may be
inaccurate, depending on use circumstances. These
measurements are indicative and cannot be used for
diagnostic purposes.
3 - Contra Indication
The device is to be operated by classified personnel only. As stated in the intended use, the device is
intended to be used in a medical environment. During the intended use the test subject will deliver
energy. Application of the wrong dosis of energy could lead to permanent damage of the test subject
health. Only use this device under supervision of a medical physician.
4 - Definition of parts
7/21M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25

1. Service Connector
2. Communication Interface
Module (CIM)
3. On/Off switch
4. Equipotential bonding plug
5. Safety symbols tag
6. Serial number tag
7. Motor compartment for
height adjustment and drive
8. Height adjustment (optional)
9. Walking surface (APPLIED
PART)
10. Front bar
11. Connector for external
emergency stop
12. Magnetic contact for safety
belt
5 - Validity
This manual covers all VaIiant 2 Pediatric versions starting with the following serial number:
938904 Valiant Pediatric: S/N 20140001
Date of issue: June 14
6 - Install your treadmill
1. While unpacking the Lode treadmill ergometer, leave the transport straps on both ends in place.
2. Place the treadmill in the location where it will be used.
3. Remove Both transport straps and remaining packaging materials.
4. The power supply cord should be installed by authorised service personnel and instructions for
correct connection and anchoring must be ensured, securing that the requirements of clause 8.11.3 of
IEC 60601-1:2005 are met.
5. Remove all objects from the walking surface.
6. Switch on the unit with the on/off button and wait until the self-test is carried out. The product is
ready for use after you have heard a series of “beeps”.
8/21M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25

7 - Maintenance
7.1 - Emergency stop installation
When your treadmill is delivered with an emergency stop, please note
the following:
The plug of the emergency stop button needs to be placed in the back
connector of the console on the front handrail.
Some emergency stop buttons have a connector for another emergency
stop. You can place the spare dummy there in case you have one
button.
Also make sure that the magnet of the emergency lanyard is connected to the console.Otherwise the
treadmill will not operate.
Maintenance should be carried out on a regular and planned basis. We recommend to check the unit
annually. This may be done by your local dealer. It is also recommended that a record of the service
history is kept for all activities relating to service and maintenance.
Maintenance and all repairs should only be carried out by an authorized agency. The manufacturer will
not be held responsible for the results of maintenance or repairs by unauthorized persons.
The check up and/or technical maintenance must be carried out conform the procedure described in
the service manual of the unit.
Opening of the equipment by unauthorized agencies is not allowed and will terminate any claim to
warranty.
Lode will make available on request circuit diagrams, component part lists, descriptions, calibration
instructions, or other information that will assist authorized service personnel to repair those parts of
the ergometer that are designated by Lode as repairable by authorized service personnel.
8 - Troubleshooting
For a complete overview of possible error message and the solutions belonging to these messages,
please consult the service manual of the ergometer.
9/21M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25

8.1 - Belt alignment
Place the allen key on the left
bolt while standing behind the
treadmill as shown on the
picture.
Adjusting the belt tension is
very easy with the key on the
left side. Turning the key
clockwise will make the belt
move to the right side of the
treadmill. Turning the key
counterclockwise will make the
belt go left.
The red marked area shows where you can check the belt alignment. The goal is to align the belt edge
exactly in the center of the hole.
10/21M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Lode Tapis roulant

Lode
Lode Valiant 2 cpet Manuale utente

Lode
Lode Katana Manuale utente

Lode
Lode ERGOMETERS Manuale utente

Lode
Lode Valiant Manuale utente

Lode
Lode Schiller AT-10 Manuale dell'operatore

Lode
Lode Valiant Ultra Manuale utente

Lode
Lode OEM Manuale utente

Lode
Lode Edan ST-1212 Stress Manuale utente

Lode
Lode CORIVAL CPET Manuale dell'operatore

Lode
Lode Valiant 2 Rehab Manuale utente