●Do not install the chiller in closets, cabinets, or other small unventilated places.
●Make sure there is 100cm clear space around the chiller vents when in use.
●Never cover the intakes or exhaust openings with clothes, towels, or other objects.
●Never turn, or store the chiller upside down.
●Do not climb, sit, or stand on the chiller, or place objects on top of it.
●Use extreme caution when operating near children, the elderly or inrm.
●Never insert ngers of foreign objects into the ventilation grilles or other parts of the chiller.
●Do not place heavy objects on the power cord or run the cord under carpets or rugs.
●Do not touch, or use the chiller with wet hands.
●The operators of the chiller must be at least 18 years old.
CAUTION

Electricity is very dangerous, in order to prevent accidents or death please pay
attention to safety and ensure you fully read this instruction manual before use.
1. During and after transportation, the Thermo CT2 Unit must stay upright on a stable
surface at all times.
2. After transportation, and before use, the chiller must be left for 24hrs for the
refrigeration gas to settle.
3. Make sure there are no water leaks from the Thermo CT2 Unit, or inlet and outlet pipes
when connected to the Recovery PRO.
4. Make sure the Thermo CT2 Unit is plugged into an AC socket or extension cable that is
suitable for use, properly grounded, has a built in surge protector and preferably is IP65
rated.
5. Ensure the Thermo CT2 Unit is kept dry at all times, do not immerse, splash or spray the
unit with water. If the unit does get wet, unplug it immediately and do not use.
6. Never leave the Thermo CT2 Unit switched on when using the Recovery PRO, always
ensure the unit is switched off during your cold water therapy session.
7. If the Thermo CT2 Unit stops working or doesn't work when switched on, unplug it
immediately and do not use.
8. We accept no responsibility for misuse or failure to use this equipment safely as
instructed.
2
WARNING

At present, Tuya Smart can only support 2.4G WiFi signal. Therefore, before connecting the
phone to the chiller, please conrm that the WiFi used by your phone is in the 2.4G frequency
band. It will not be able to connect to the chiller if it is in the 5G band.
3
Smart LifeTuya Smart
You can use the Tuya Smart or Smart Life mobile app to control your Thermo CT2 Unit
via WiFi. Download the app from the respective app store for your device. Use the QR
Code below to start now.
Please note: As these are both 3rd party apps, we accept no responsibility for
incompatibility or issues when using this with your LUMI Thermo CT2 unit.
USING THE WIFI CONNECTED MOBILE APP

CUSTOMER SUPPORT
If you have any questions about setting up or using your LUMI product, please visit
our website for further information, faqs, troubleshooting and customer support.
Follow this QR Code for our
product guides and videos
YOUR JOURNEY BEGINS!
1. 1 x LUMI Thermo CT2™ External Chiller / Heater Unit
2. 3 x Washable high-density particle water lters
3. 1 x Washable hair lter
4. 2 x Water Pipes
5. 1 x Power cable
6. 1 x Fittings and Accessories Pack
UNPACKING YOUR LUMI THERMO CT2 CHILLER
1. First nd a suitable ventilated area and at solid surface to unpack and set up.
2. Complete the steps in the QUICK START GUIDE to assemble your LUMI Thermo CT2™.
3. Read carefully through this user manual before using the LUMI Thermo CT2™.
TAKE A MOMENT TO FIND OUT WHAT’S IN THE BOX
4

We always end up
right where we are
supposed to be,
right when we are
meant to be there.
Sometimes we just
need a little time
to recover.
TRUST THE PROCESS
#lumitherapy

1. Ensure you have assembled your LUMI Recovery PRO™ ice bath rst before continuing.
2. Place the Thermo CT2™ chiller on a stable surface near to the LUMI Recovery PRO™ ice bath.
3. Connect both the Inlet and Outlet water pipes, and ensure the valves are 'hand tight'.
4. Next, ensure the hair lter is installed and lter is fully secured using the supplied wrench.
5. Insert the blue particle water lter into the bottle, and ensure the bottle is 'hand tight'.
1. Plug in and switch on the Thermo CT2™ unit, the unit will self-prime until its ready to use.
2. Once the chiller has nished its priming cycle it will start to chill and lter the water within a
few minutes.
3. It can take up to 3-4hrs to chill the water from 18°C down to a frosty 3°C.
4. Once the desired temperature is reached, switch off the Thermo CT2™ unit before starting
your cold water therapy session.
6
SETTING UP THE THERMO CT2
SWITCHING ON THE THERMO CT2
QUICK START GUIDE
●Your LUMI Recovery PRO™ can be lled with cold or hot water, up to a maximum temperature
of 50°C. Always start lling with room temperature water rst, adjusting to your desired
temperature as the LUMI Recovery Pod™ gets closer to full.
●Never ll your LUMI Recovery Pod™ to more than ⅔ full so to compensate for your body mass
and displacement of water when you enter. It's always best to start ½ full and then adjust
afterwards.
WHEN FILLING WITH WATER

7
BUILT TO LAST
The LUMI Thermo CT2
housing is built with a strong
lightweight steel frame and
nished in a easy to clean
black powder coated nish.
WATER FILTERS
The LUMI Thermo CT2 not only
chills but helps keep your ice
bath water clean with a
washable high-density
particle water and hair lter.
WATER FILTER BAY
This is where you install the
high-density particle water
and hair lter.
PLUG & PLAY
Quality built hoses easily connect between the
LUMI Thermo CT2 and the LUMI Recovery PRO
ice bath, circulating fresh, clean, cold water.
TOUCH SCREEN & WIFI ENABLED
Your can control your LUMI Thermo
CT2 unit either via the built in touch
screen or WIFI enabled mobile app
for ease of use.

8
QUALITY BUILD
The Lumi Thermo CT2 unit is
the industry's best chiller/
heater and lter combination,
low maintenance, made to
last, with insulated housing and
quality built components.
SUPER COOLING & HEATING
The LUMI Thermo CT2 unit keeps
the water as cool as 3°C (37°F),
and can warm the water up to
42°C (107.6°F).
PORTABLE
Unlike some ice bath chillers on
the market, the LUMI Thermo
CT2 unit sits on heavy duty
lockable castors for easy
positioning.

Indice
Altri manuali Lumi Refrigeratore