Luminaire led ARV13 Manuale utente

INSTALLATION GUIDE FOR
ARV13/YRV13 LED with SHCAB
RETAIN THESE INSTRUCTION FOR FUTURE USE
One Lithonia Way, Conyers GA 30012 | 1.800.705.SERV (7378) | www.luminaireled.net | © 2020 Acuity Brands Lighting, Inc. All rights reserved.
Page 1of 4
SAFETY PRECAUTIONS
WARNING - Risk of fire or electric shock. Basic safety precautions should always be
followed when using electrical equipment.
WARNING - This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and operation of the
product and the hazards involved.
WARNING - Disconnect power to all circuits before wiring fixture.
WARNING - Install inaccordance with allnational, state, and local codes.
WARNING - The main (white LED) circuit and the auxiliary circuit (Nightlight) are to
be wired to separate circuits that can’t be powered on simultaneously.
WARNING - Do not connect to an ungrounded supply.
WARNING - Read all fixture markings and labels to ensure correct installation of
fixture.

INSTALLATION GUIDE FOR
ARV13/YRV13 LED with SHCAB
RETAIN THESE INSTRUCTION FOR FUTURE USE
One Lithonia Way, Conyers GA 30012 | 1.800.705.SERV (7378) | www.luminaireled.net | © 2020 Acuity Brands Lighting, Inc. All rights reserved.
Page 2of 4
CAN ICES-005 (A) / NMB-005 (A)
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
ISED CANADA STATEMENT / DECLARATION POUR ISDE CANADA
This class A lighting equipment complies with Innovation, Science and Economic
Development (ISED) Canada Standard for radio interference-causing equipment ICES-
005, 5th edition.
Ce matériel d’éclairage de classe A est conforme avec la norme sur le matériel
brouilleur radio NMB-005, 5ième édition, publié par innovation, science et
développement économique (ISDE) Canada.

INSTALLATION GUIDE FOR
ARV13/YRV13 LED with SHCAB
RETAIN THESE INSTRUCTION FOR FUTURE USE
One Lithonia Way, Conyers GA 30012 | 1.800.705.SERV (7378) | www.luminaireled.net | © 2020 Acuity Brands Lighting, Inc. All rights reserved.
Page 3of 4
INSTALLATION PROCEDURE
1. Remove Luminaire from carton and check for damage
2. Unscrew outer ring/eyelid by turning counter-clockwise.
3. Set aside lens and ring/eyelid for later use.
4. Dis-connect Driver wires to LED Board Assembly. Set wire nuts aside for later use.
5. Remove LED Board Assembly by loosening (2) 8-32 hex nuts located closest to the center
of reflector. Set aside for later use.
6. Remove ¼”–20 screws (4) that attached the Base Plate to the SHCAB.
7. Apply gasket to back plate.
8. Mount SHCAB to surface using (4) ¼ bolts (not included). While the fixture may be
mounted directly to junction box using keyhole slots provided, we recommend using the
¼” bolts for maximum vandal resistance. Recommended mounting hole locations can be
located on the back surface of the SHCAB – see Figure on page 3. (For wall mounting, the
SHCAB should be mounted with the arrow pointing upward – see step 11.)
9. Connect all supply wires in accordance with national and local electrical codes.
10. Wires should be pushed through center hole in SHCAB and should be contained in
recessed junction box.
11. Locate set screw. The fixture must be mounted so this screw is aligned with the three
o’clock position.
Ring / Eyelid
Set Screw
Lock
Unlock
Set Screw
Ring/ Eyelid
Set Screw
Ring / Eyelid
Unlock
Lock
WARNING - The main (white LED) circuit and the auxiliary circuit (Nightlight) are to be wired to
separate circuits that can’t be powered on simultaneously.

INSTALLATION GUIDE FOR
ARV13/YRV13 LED with SHCAB
RETAIN THESE INSTRUCTION FOR FUTURE USE
One Lithonia Way, Conyers GA 30012 | 1.800.705.SERV (7378) | www.luminaireled.net | © 2020 Acuity Brands Lighting, Inc. All rights reserved.
Page 4of 4
12. It is recommended to align the screw receiver slots to the 3 O’clock position for wall
mounting.
13. Pull the wire harness through the Base Plate.
14. Re-attached the Base Plate using the ¼” – 20 screws.
15. Re-install LED Board Assembly using (2) 8-32 nuts. Do not over tighten.
16. Connect Driver wires to LED Board Assembly using supplied wire nuts from Step 4.
Connect black to blue and red to red.
17. Place lens on fixture.
18. Align outer ring/eyelid so that the screw access hole is in the two o’clock position and
engage with back plate.
19. Firmly turn ring /eyelid in the clockwise direction to engage with base plate.
20. Using tamperproof tool, unscrew the set screw until first resistance is felt. It is not
necessary or desirable to turn screw past point of first resistance.
21. Energize and test.
22. When removing ring/eyelid, the set screw must be rotated to the fully retracted position.
Base Plate
4 Screws
SHCAB
Drill
Points
UP Arrow
Set Screw
Location
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Luminaire led Lanterna