Lynx LHPM Guida

CARE & USE/INSTALLATION
MAKE THE MOST OF YOUR
LYNX POST MOUNTED HEATER (LHPM)

2
|LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION
WARNINGS
READ THIS MANUAL CAREFULLY and completely before using your grill to reduce the risk of:
1. Fire
2. Burn hazard, personal injury or property damage
3. Unapproved installation or servicing.
THIS PRODUCT IS DESIGNED FOR OUTDOOR RESIDENTAL USE ONLY.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read
the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Read this manual thoroughly before installation, use, or servicing of this product.
1. The burning of gas cooking fuel generates some by-products which are on the list of substances which are
known by the State of California to cause cancer or reproductive harm.
2. California law requires businesses to warn customers of potential exposure to such substances. To minimize
exposure to the substances, always operate this unit according to the use and care instructions found in this
manual. Be certain to provide adequate ventilation.
IF YOU SMELL GAS:
1. Shut off all gas supply lines to the heater.
2. Extinguish any open flames.
3. If odor continues, keep everyone away from the
grill accessory and immediately call your gas
supplier or your fire department.
1. DO NOT store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
S’IL Y A UNE ODEUR DE GAZ:
1. Coupez l’admission de gaz du chauffage.
2. Éteindre toute flamme nue.
3. Si l’odeur persiste, éloignez-vous de
l’appareil de chauffage et appelez
immédiatement le fournisseur de gaz ou le
service d’incendie.
1. Ne pas entreposer ni utiliser de l’essence ni
d’autres vapeurs ou liquides inflammables dans le
voisinage de l’appareil, ni de tout autre appareil.
WARNING
DANGER
WARNING
DANGER
AVERTISSMENT
WARNING! CALIFORNIA PROPOSITION 65

LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION |3
The installer must leave these instructions with the owner. Only those who are certified to do so should
perform service on these heaters.
• At all times maintain clearance to combustible materials
as further specified in this manual. Failure to do so can
result in serious fire hazazrd.
• Never operate heaters in atmosphere containing flamable
vapours or combustible dusts.
• This heater is equipped with an electronic and automatic
ignition device. Do not attempt to light the burner by
hand. Failure to comply can result in a serious fire and
personal injury hazard.
• Certain materials, when stored under this heater, are
subjected to radiant heat that can soften, distort or
otherwise be damaged, special care should be taken of
plastic materials
• Appliance surfaces, other than the obvious flame
and emitter surfaces, attain elevated temperatures
during operation. Do not touch the heater head during
operation. Everyone should be alerted to this hazard to
avoid burning.
• Children should be strictly supervised when in the area
of this heating appliance. Playing or running around the
structure should be strictly forbidden.
• Clothing or other flammable materials should not be
hung on or near this heater.
CAUTION AND GENERAL SAFETY
IMPORTANT

4
|LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION
PRE-INSTALLATION OVERVIEW
WHAT YOU WILL RECEIVE:
TOP REFLECTOR
POLE ASSEMBLY
HARDWARE
ELECTRIC SWITCH KIT
HEATER HEAD ASSEMBLY
Assembly delivers in 4 boxes

LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION |5
A MESSAGE TO OUR CUSTOMERS
Lynx manufactures many accessory cooking appliances to compliment your
Lynx grill and your desire for truly superior cooking results.
Your appliance has been designed and built with meticulous attention to
detail and it offers some unique and powerful features. You can achieve
maximum performance and enjoyment of these features only by carefully
reading this manual.
This manual includes important safety tips. You should keep it handy for
easy reference.
Also, at Lynx, we enjoy hearing from our customers. We like to hear about
your successes but also about any difficulties you are having. Please
feel free to contact us with any questions or problems, or just to share a
new recipe. Please include the model number of your appliance in your
correspondence.
With the proper use and care this product will provide years of trouble-free
service.
Should your Lynx appliance change ownership, please make sure that the
new owner receives this manual.
Thanks again for your purchase. Enjoy!

6
|LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION
PRE-INSTALLATION OVERVIEW
MOUNTING PLATE HOLE PATTERN
(FULL SIZE)

LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION |7
LIGHTING INSTRUCTIONS
Read the ‘User Manual/Installation Instructions carefully and completely before using your heater to reduce
the risk of fire, burn hazard or other injury.
WARNING
LIGHTING
1. Open manual gas supply valve (ensure gas supply lines have been purged).
2. Turn on switch to energize electric supply.
3. The electronic control module will begin the ignition period in 3 seconds.
4. The gas valve will open and ignition spark will commence and continue for 20 sec.
5. If flame starts and “is detected”, flame will continue until turned off.
6. If no flame is detected, the gas valve will close after 20 sec. A “wait’ period commences and lasts approximately
5 sec. and a second trial for combustion commences. The electronic control will attempt three trials for ignition
before locking out for approximately 5 minutes at which time it will automatically try again. Electronic control of
heater can be re-set by de-energizing and re-energizing electric power.
SHUT DOWN
1. Turn off power to electronic control.
2. For longer periods of shut down, also close manual gas supply valve.
SUPPLIES NEEDED
1. Heater post anchoring hardware.
2. Materials necessary to construct a concrete base for floor mounting.
3. Gas supply line that is installed to the Gas and Electric Supply according to the: National Fuel Gas Code, ANSI
Z.223.1 (NFPA 54) in the US and CAN/CGA B149.1 and B149.2 Installation Codes in Canada. 4. Electrical supply
rated at 24 Vac with two stage control

8
|LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION
LOCATION PLANNING
LOCATION REQUIREMENTS
Wind protection has an important influence on the human body’s ability to retain radiant heat.
Use natural or newly built wind barriers where possible, such as existing buildings, shrubbery or tree lines and
fences.
One Lynx Patio heater, at high fire and in windless conditions has a comfort radius of about twelve feet.
A series of heaters providing area heat should be placed about 14 feet apart.
WARNING
This heater is NOT approved for any indoor Residential application. If in doubt of your application
consult with your local fire marshal or gas authority having jurisdiction. Indoor spaces include but are
not limited to attached garages, solariums, living quarters etc.
A patio that has been almost entirely closed in with a roof and windbreak walls or a tent may be considered an
indoor location by some code authorities. Venting of the flue gases is accomplished by means of an interlocked
fan. Refer to the National Fuel Gas Code, ANSI Z.223.1 (NFPA 54) in the US and CAN/CGA B149.1 and B149.2
Instalation Codes in Canada.
1. Never locate the heater directly below electrical lines, gas lines or sprinkler systems.
2. Do not locate heater too close to vinyl or plastic wall coverings. These materials may discolour or soften
well before they reach combustible limits.
3. Always allow room for removal of the top reflector and heater head for maintenance purposes.
4. The heater aspirates air for combustion. Do not locate heater where there are severe draft conditions or
airflow restrictions to the heater head base.

LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION |9
CLEARANCE TO COMBUSTIBLE MATERIALS
NOTE: Some materials deteriorate or soften at sustained
temperatures below 160°F.
Consult material manufacturer for recommendations
The following clearance data is based on a maximum
limit of 90°F plus ambient temperature. Note with an
ambient temperature of 70°F the surface temperatures
at the clearance distances listed below could reach
160°F. Care should be taken with placement of plastic
or vinyl in the proximity of the heater as they tend to
distort and soften at these temperatures.
18”
22”
33”
High fire rate: 53,000 btuh
Low fire rate: 46,000 btuh
Gas supply pressure: Minimum Maximum
Natural Gas: Minimum 6.5 ” W.C. at orifice
14” W.C. at inlet.
Electric Supply: 24 VAC, 0.8A
Installation or repair should only be done
by personnel qualified for the installation
of powered gas appliances.
Unit is for Natural Gas only.
POWER/GAS SPECIFICATIONS
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ psig (3.5 KPa).

10
|LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION
INSTALLATION INSTRUCTIONS
EQUIPMENT DIMENSIONS
Installation must comply with local building codes and/or, for the USA/National Fuel Gas Code, ANZI Z 223.1 (NFPA
54) and for Canada, CAN/CGA B149.1 and B149.2, National Gas and Propane Installation Code (latest editions).
Appliance must be electrically grounded in accordance with local codes or, in their absence; the National Electrical
Code, ANSI/NFPA 70 in the USA, CSA CZ21.1 Canadian Electrical Code in Canada.
Altri manuali per LHPM
1
Indice
Altri manuali Lynx Riscaldatore da esterno