M-system 20VS10D Manuale utente

20VS1D
P. 1 / 2EM-4431
ISOLATION AMPLIFIER
(top adjustment, for current output, output isolation) MODEL 20VS1D
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Amplifier ....................................................................... (1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
•Locatethepowerinputratingmarkedontheproductand
confirm its operational range as indicated below:
15V DC ±2%, approx. 35mA with 20mA output
•Whenthereisspikenoisesinthepower,makealterwith
an appropriate capacitor and inductor to cut it off.
■ENVIRONMENT
•Indooruse
•Whenheavydustormetalparticlesarepresentintheair,
install the unit inside proper housing with sufficient ven-
tilation.
•Donotinstalltheunitwhereitissubjectedtocontinuous
vibration.Donotsubjecttheunittophysicalimpact.
•Environmentaltemperaturemustbewithin0to60°C(32
to140°F)withrelativehumiditywithin10to95%RHin
order to ensure adequate life span and operation.
■WIRING
•Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
•Mounting multiple isolator modules on single printed
wiring board could cause beat. In such case, use the way
shown as below to make the power supply oscillation fre-
quency of each module to a same one for prevention.
22kΩ 22kΩ
17
18
20VS1D
17
18
20VS1D
17
18
20VS1D
■INSTALLING THE MODULE
Whenitisinstalledontheprintedwiringboard,landdiam-
eterø1.5andthrough-holeø0.9arerecommended.
■AND ....
•Theunitisdesignedtofunctionassoonaspowerissup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
•With voltage output, do not leave the output terminals
shortcircuited for a long time. The unit is designed to en-
dure it without breakdown, however, it may shorten ap-
propriate life duration.
18 (.71) 49 (1.93)
12345678915161718
22212019
36353433
0.5 (.02)
0.3 (.01) 0.5 (.02)
14 (.55)
14 (.55)
5.5 (.22)
20.32 (.80) 13.97 (.55)
7.62 (.30)
2.54 (.10)
1.27 (.05)
19.25 (.76)
SPAN
ZERO
TERMINAL CONNECTIONS
■EXTERNAL DIMENSIONS mm (inch)
■TERMINAL ASSIGNMENTS
+
–
+
–
OUTPUT
+16V
COM (0V)
–
16V
9
8
15
16
7
1
2
3
5
20
19
+
–
EXCITATION
*
1
INPUT
POWER SUPPLY
*To be used in the printed wiring board on which the unit is mounted.

20VS1D
P. 2 / 2EM-4431
APPLICATION EXAMPLE
22
21
20
19
VREF
VOUT
R1
R2
IC1 IC2
R3
10kΩ
R4
6.08kΩ +
–
+
–
+
–
INPUT VIN
Toadjustzeroandspan,usetopadjusters.
Forinput1-5VDC,outputis4-20mADC.
Inordertoshiftthezeroatinput,supplyreferencevoltage
topin21.Thefollowingformulashowshowmuchthezero
shifts. (input signal at pin 20 = VIN; output signal at pin 1 =
VOUT; reference voltage = VREF;zeroshift=VOUTSHIFT.)
10kΩ
VOUTSHIFT = - (––––––) × VREF
R1
(10kΩ+R1)
VOUT = ––––––––– × VIN + VOUTSHIFT
R1
In order to attenuate input signal, connect a resistor to pin
22. The following formula shows the attenuated output.
R2
VOUT = (––––––––––––) × VIN
R2+6.08kΩ
External resistors and adjusters make zero and span ad-
justmentavailable.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp
■PIN ASSIGNMENT
NO. FUNCTION
1 Current Output (+)
2 Current Output (-)
3NC
4NC
5NC
6NC
7Excitation(+)
8Excitati
on (-
)
9Excitation(COM)
15 Power Supply (+)
16 Power Supply (-)
17 Synchronous Input
18 Synchronous Output
19 Input (-)
20 Input (+)
21 Input Amplification
22 Input Attenuation
33 NC
34 NC
35 NC
36 NC
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the pins.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
Formatchingthesignaltoareceivinginstrumentorincase
ofregularcalibration,adjusttheoutputasexplainedinthe
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO:Apply0%inputandadjustoutputto0%.
2) SPAN:Apply100%inputandadjustoutputto100%.
3) CheckZEROadjustmentagainwith0%input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regularcalibrationprocedureisexplainedbelow:
■CALIBRATION
Warmuptheunitforatleast10minutes.Apply0%,25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet.
Indice
Altri manuali M-system Amplificatore