Majorcom: LN-8M Manuale utente

www.majorcom.fr • commercial@majorcom.fr
Siège Social : 56, chemin de la Flambère - 31300 TOULOUSE (France) • Tel. +33 (0)5 61 31 86 87 • Fax. +33 (0)5 61 31 87 73
S.A.S Capital 288 768 € • SIRET 334 579 869 000 28 • NAF 2640Z • TVA Intracommunautaire FR 12334579869
MAJORCOM \ QUALITE \ ENREGISTREMENT DES DOCUMENTS \ ADMINISTRATIF \ ENR-12-PEM-V04
LN-8M
Digital Player 8 Messages

www.majorcom.fr • commercial@majorcom.fr
Siège Social : 56, chemin de la Flambère - 31300 TOULOUSE (France) • Tel. +33 (0)5 61 31 86 87 • Fax. +33 (0)5 61 31 87 73
S.A.S Capital 288 768 € • SIRET 334 579 869 000 28 • NAF 2640Z • TVA Intracommunautaire FR 12334579869
MAJORCOM \ QUALITE \ ENREGISTREMENT DES DOCUMENTS \ ADMINISTRATIF \ ENR-12-PEM-V04
It is important to fully understand this manual before use to ensure optimum product performance.
The installation of this equipment under unsuitable conditions such as those mentioned below may cause
malfunction or premature wear.
Caution :
Warning :
• Do not repair or alter the equipment
• Do not handle with wet hands: risk of electric shock
• Do not install the product in a damp or dusty atmosphere: risk of electric shock
• Do not spray water directly during cleaning
• Clean the exterior gently with a soft cloth
• Do not use chemicals, abrasives or detergents.
Precautions :
• Connect the power supply completely to the socket (A bad connection may cause a fire hazard)
• Do not insert metallic foreign bodies into the ventilation devices (risk of electric shock)
• Install the product in a well-ventilated room
• Do not install the product near heat sources
• Do not throw or blow the product
• If smoke or odor appears, stop operation immediately, turn off the power, unplug and contact your service
representative.
Although the unit is equipped with a circuit breaker, do not reverse the + and - polarity. (Do not short-circuit the
unit).

www.majorcom.fr • commercial@majorcom.fr
Siège Social : 56, chemin de la Flambère - 31300 TOULOUSE (France) • Tel. +33 (0)5 61 31 86 87 • Fax. +33 (0)5 61 31 87 73
S.A.S Capital 288 768 € • SIRET 334 579 869 000 28 • NAF 2640Z • TVA Intracommunautaire FR 12334579869
MAJORCOM \ QUALITE \ ENREGISTREMENT DES DOCUMENTS \ ADMINISTRATIF \ ENR-12-PEM-V04
Features :
• Up to 8 hierarchical MP3 messages can be remotely controlled via dry contacts with front panel playback.
Possibility to read messages manually.
• The SD card contains the French and English evacuation messages, AFNOR 32001and some Chimes or Rings
sounds.
• It is possible, using a simple SD card reader, to load any type of MP3 messages for up to 2 GB.
• Possibility of emergency power supply 24V DC.
MP3 Format and Sampling up to 192 Kps
Storage of 2GB microSD messages (SD adapter included)
Dry contact 8 trips on Euro block terminal block
Outputs 0 dB and dry contact on Euro block terminal block
Power Consumption (W) 15 W
24 V DC power supply and 24 V DC backup
Dimensions (WxHxD) 483 x 44 x 215 mm, 1U
Weight (kg) 1.8 Kg

www.majorcom.fr • commercial@majorcom.fr
Siège Social : 56, chemin de la Flambère - 31300 TOULOUSE (France) • Tel. +33 (0)5 61 31 86 87 • Fax. +33 (0)5 61 31 87 73
S.A.S Capital 288 768 € • SIRET 334 579 869 000 28 • NAF 2640Z • TVA Intracommunautaire FR 12334579869
MAJORCOM \ QUALITE \ ENREGISTREMENT DES DOCUMENTS \ ADMINISTRATIF \ ENR-12-PEM-V04
Front Panel :
1 – Place to Insert MICRO SD card up to 16 GB (2 GB supplied with SD adapter).
2 - Navigation Button to go from next / previous message, playback and manual pause.
3 - Message reading indication. The LED is ON when a message is playing.
4 - Power indication. The LED is ON when the unit is turned on.
Rear Panel :
5 - Power connector. This unit can operate from a supplied 24 VDC voltage.
6 - Output remote control by dry contact NO to control another device.
7 - Connector to trig messages by dry contact. Each message has its own contact on these terminals.
8 - Balanced line level output connector.
9 - Connector for emergency power supply 24V DC.

www.majorcom.fr • commercial@majorcom.fr
Siège Social : 56, chemin de la Flambère - 31300 TOULOUSE (France) • Tel. +33 (0)5 61 31 86 87 • Fax. +33 (0)5 61 31 87 73
S.A.S Capital 288 768 € • SIRET 334 579 869 000 28 • NAF 2640Z • TVA Intracommunautaire FR 12334579869
MAJORCOM \ QUALITE \ ENREGISTREMENT DES DOCUMENTS \ ADMINISTRATIF \ ENR-12-PEM-V04
Procedure to add messages:
Remove the microSD card from the unit and use the supplied microSD to SD adapter and then insert the card into
your SD port on your computer. If you do not use the supplied card please reformat your card to FAT16 or FAT32
format.
The messages must be in MP3 format with a maximum sampling of 192Kbps.
Once the messages have been chosen and copied to your card it is imperative to rename the messages as follows:
Message n ° 1: 001.mp3
Message n ° 2: 002.mp3
...
Message n ° 8: 008.mp3
The three-digit number indicates the location and order of messages.
CAUTION: When you remove the micro SD card from its slot, do not forget to restart the unit via the mains
socket (transformer 24VDC).
Connection output :
The output audio signal is 0dB balanced on eurobloc connector.
Indice
Altri manuali Majorcom: Lettore multimediale