SPECIFICATIONS
MALEKKOHEAVYINDUSTRY.COM
VOLTAGE BLOCK MANUAL V.1
FORMAT:
EURORACK
DIMENSIONS:
20HP, 20mm deep
INTERNAL AND EXTERNAL SIGNALS (3.5mm jacks):
0-5V Logic I/O
MAX CURRENT:
+12V: 120mA
-12V: 15mA
+5V: n/a
PG. 1

INSTALLATION
MALEKKOHEAVYINDUSTRY.COM
VOLTAGE BLOCK MANUAL V.1
RED STRIPE TO SOLID WHITE LINE
Remove module from packaging.
Power down your modular synthesizer and disconnect the power cable from the wall
outlet.
Attach the included power cable to the module’s power connector and connect the
other end to the power distribution bus in your EuroRack synthesizer case. Match the
red stripe of the cable to the solid white line on your Voltage Block.
Position the module on the mounting rails in your EuroRack case and screw down
mounting screws. Power up! If your case does not turn on properly then you have
installed the module incorrectly. Simply power down and make sure to follow the
diagram when reconnecting the module.
PG. 2

DESCRIPTION
8 independent 16-stage CV sequencers packed with performance features and
presets makes the Voltage Block the ultimate CV tool. Create quantized or unquan-
tized sequences for each output, record your modulation changes, tie sequences
together, mute on the fly, randomize your outputs and so much more. The Voltage
Block can be used stand-alone or pairs well with Varigate 4 and especially Varigate
8+ to share clocking and preset save/recall. All in 20hp.
FEATURES INCLUDE:
8 channels + 16 stage per channel of CV modulation
Save and recall presets
Live slider/automation recording
Scale selection per output or unquantized 0-5V
Interpolation option for each step for smooth or stepped modulation
Offset and attenuation for CV input
Clock and CV operation modes
Sequence length can be set from 1 to 16 steps
Clock can be divided by up to 16
Randomize all outputs per step
Easy control over stage length
Rest/Hold gate input
Glide per stage
Forward, Reverse, Pendulum or Random directions per channel
Mutes per channel
Mutes per sequence stage
Tie presets together for “Song Mode”
Can be linked to the Varigate 8+ to share clocking and preset save/recall (up to 100
presets)
Clock in
Busboard CV gate
MALEKKOHEAVYINDUSTRY.COM
VOLTAGE BLOCK MANUAL V.1
PG. 3

MALEKKOHEAVYINDUSTRY.COM
OVERVIEW 1
OUTPUTS 1-8: 0-5VCV output
channels with LED indicators.
CLOCK IN: External CLOCK
INPUT.
CLOCK/CV/SLAVE: Switch
between different interpolation
modes. CLOCK, CV or SLAVE
(SLAVE for Varigate 8+ connected
to the same bus).
RESET/HOLD: Gate input for
RESET while in CLOCK mode
and HOLD if Voltage Block is set
to CV interpolation mode.
SLIDERS: Control CV pitch
amount per channel and live
recording/automation. Also used
to change the SCALE of a given
channel.
STEP LED Indicators and other
functions.
STEP BUTTONS: Select to
access various parameters for
each step or the 8 available
sequencer outputs including
SHIFT + CLEAR, SMOOTH,
RANDOM, FREEZE, FORWARD,
REVERSE, PENDULUM AND
RANDOM SEQUENCE.
PG. 4
VOLTAGE BLOCK MANUAL V.1

MALEKKOHEAVYINDUSTRY.COM
OVERVIEW 2
MUTE: Mute per channel OR mute per
step.
LENGTH: Select and then adjust a step
slider to control the amount of steps per
sequence.
SHIFT: Extra feature access (for CLEAR,
SMOOTH, RANDOM, FREEZE,
FORWARD, REVERSE, PENDULUM
AND RANDOM SEQUENCE)
RECALL: Hold and select a STEP button
to recall a saved preset.
SAVE: Hold and select a STEP button to
save a preset.
SCALE: Select and adjust sliders to
change a given sequence scale.
PG. 5
OFFSET: When in CV interpolation mode, OFFSET up to 16
steps.
ATTENUATE: When in CV interpolation mode, adjust the
incoming CV signal by adjusting the ATTENUATE control knob.
DIVIDE: Divide your sequences down to 16.
VOLTAGE BLOCK MANUAL V.1

MALEKKOHEAVYINDUSTRY.COMMALEKKOHEAVYINDUSTRY.COM
CREATING YOUR FIRST SEQUENCES
Set to “CLOCK” or “SLAVE” (busboard
slave) or “CV” depending on your
setup. The Voltage Block always
requires an input or to slave in order to
play.
Patch the outputs to your other
module 1v/oct inputs for creating
melodies.
Adjust sliders for corresponding
channels - as you move the the slider,
the changes in voltage/pitch of each
step will be recorded.
NOTE: By default, there are 16 steps
per each GATE pattern/sequence.
If you’re in CLOCK or SLAVE mode
and want to adjust the voltage of
particular step, hold the corresponding
STEP button while adjusting a slider.
To clear an existing
sequence, simply
select SHIFT, select
the channel you wish
to clear and then
CLEAR (step #9).
Follow these instructions
for GATE channels 2-8.
Now you can change the SCALE of that
sequence by selecting the SCALE
button so that it’s lit and then moving
the slider for that channel. You will see
the LED’s light up for each correspond-
ing scale. See Pg.11 for all of the
available scales. IF THE SLIDER IS
SET ALL THE WAY DOWN, THE
VOLTAGES/PITCH WILL BE
UNQUANTIZED.
PG. 6
VOLTAGE BLOCK MANUAL V.1

SEQUENCE DIRECTION, SMOOTH AND RANDOMIZING
MALEKKOHEAVYINDUSTRY.COM
SEQUENCE DIRECTION can be
changed by selecting SHIFT, the
channel which you’d like to change
and then one of the corresponding
step buttons. Forward is on by default
but REVERSE, PENDULUM AND
RANDOM SEQUENCE are available.
To add SMOOTHING (glide) to a step,
select the SHIFT button, then select
SMOOTH and then a step button. To
remove smooth from a step simply
select that step button again (LED no
longer lit).
To RANDOMIZE the voltages per step,
select SHIFT, then the channel you
want to randomize and then the RND
button. You can keep selecting RND to
continue randomizing until you find
something you like. If you want to
change the randomization at all simply
exit out of this mode (select SHIFT
again) and you can manually change
the pitch by holding a step button and
adjusting the corresponding slider.
PG. 7
VOLTAGE BLOCK MANUAL V.1

SAVING AND RECALLING PRESETS
MALEKKOHEAVYINDUSTRY.COM
The STEP buttons also act as
PRESET slots. You can save 16
presets if you are using Voltage
Block stand-alone or up to 100
presets if you’re using Voltage
Block slaved to Malekko Varigate
8+.
TO SAVE in stand-alone mode:
Hold the SAVE button while you
select one of the STEP buttons to
save to that location.
TO RECALL in stand-alone mode:
Hold the RECALL button while you
select one of the STEP buttons to
save to recall that preset.
To save while slaved to Varigate 8+
simply select the Varigate 8 preset
button you wish to save to.
Follow the same procedure to recall
a saved preset.
Varigate 8+ in SONG MODE will
also recall each corresponding
saved preset on the Voltage Block.
To find out more about save, recall
and song modes on the Varigate 8+,
visit:
https://malekkoheavyindustry.com
and download that manual.
PG. 8
VOLTAGE BLOCK MANUAL V.1
Indice
Altri manuali Malekko Apparecchiature di registrazione
Manuali Apparecchiature di registrazione popolari di altre marche

Strymon
Strymon NIGHTSKY Manuale utente

Mitsubishi Electric
Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U Manuale utente

Tews Technologies
Tews Technologies TPMC465 Manuale utente

Honeywell
Honeywell Excel 50 Manuale utente

SeaLevel
SeaLevel COMM+8.LPCI Manuale utente

Arturia
Arturia AUDIOFUSE STUDIO Manuale utente