Mark MOVILED 105/4 Manuale utente

Rev. 15.06.01
MOVILED 105/4
User Manual / Instrucciones de Usuario

1. Production Introduce
Thank you for choose this MOVILED 105/4 product, this model is the newest led moving head light
which is the latest development of the smart, efficient products, beautiful shape, smooth R & D,
combined with the advanced technology of today's stage lighting products with international
advanced electronic control technology and excellent user- friendly industrial design.
MOVILED 105/4 Led light, use 7pcs
high brightness 15 w RGBW 4 IN 1 LED source, By
careful arrangement and design, make the R,G, B,W mixing evenly and colour is pure.
Through
the built-in microprocessor control, Use the high precision of constant current control mode, the
R.G.B.W. can realize independent 0-255 of brightness adjustment, rich color changes.
Through
the menu calls the built -in program, for scenario editor and setting sound, master-slave control
mode, can do rainbow, variable strobe and electric dimming effect.
MOVILED 105/4 has quick response speed, impact resistance, good heat dissipation. Long
using life (the life of the LED is over 100000 hours) no radiation, high efficiency and energy
saving, low energy consumption, the real green products. Accept international DMX512 signal
mode.
MOVILED 105/4 applications
very widely, installati on is simple and can be used for lighting
in
large
fixed stage, the background wash, large-scale theatrical performances, stadium lighting, temporary
stage shows, television stations, conference center, professional theaters, dance halls, bars, small
theatrical performances, and public environment illumination.
2. Fixture Size
Dimension:337(L)×256(W)×352(H)mm
MOVILED 105/4 User Manual/Manual de uso 1
EN

3. Parts Introduce
4. SAFETY INFORMATION
Safety Warning: This product is only suitable for professional use, and does not apply to security
for other purposes. When you got the lights, please check the package whether have any damage
caused by transportation. If there is any damage, do not use this fixture, and please contact the
dealer or manufacturer as soon as possible. This product is only suitable for indoor, IP 20
protection class. Lamps should be kept dry to avoid Moisture, overheating or dusty environment.
Prevent lamps come into contact with water or any other liquid.
Please read the instructions before use energized or installing.
Follow through the operation of security methods and pay attention to the warning signs
on the specification and equipment.
Head
Cover
Lens Component
PCB Board
Arm Shell
Handle
Touch Screen
Horizontal Cover
Die casting aluminum radiator
Base Shell
Display Shell
Control Wheel
Head Back Cover
Focus lens component
Touch Screen Battery Button
MOVILED 105/4 User Manual/Manual de uso 2
EN

4.1 ANTI -HIGH TEMPERATURE
ta =40°C
Please don’t use the equipment if the temperature above 40℃
4.2 TO PREVENT FALLING WOUNDING
When Hang the fixture, please must verify that the facilities to be able to withstand at least 10
times or more weight of fixtures.
Please make sure the Mounting hardware is strong enough no any damage, and insurance for
the safety rope as auxiliary security fixed in other facilities will need to verify before installation.
Installing or removing the equipment, to make the pulley below the work location
4.3 UA PROTECTION
Forbid straight viewpoint with exposed bulbs to avoid UV damage to the eyes;
Do not use the equipment without the lens screen and the lid;
The lens and the light head covers should be timely replaced if any damage to rupture.
4.4 PREVENTION OF ELECTIC SHOCK
The electrical connection must only be carried out with corresponding qualifications;
Before installing, make sure you use the power voltage must comply with the
identified power, voltage and have an overload or leakage protection;
Each fixture must be properly grounded, installed in accordance with the relevant standards;
Cut off the power when stall or replace the lamp and the fuse;
Forbid using the fixture in storm or wet environment.
4.5 TO PREVENT BURNING OR FIRE
1. The fixture can't be mounted directly on the surface of ordinary combustible material.
2. The equipment must be installed away from inflammable and explosive materials.
3. The highest temperature is 40 ° C when the equipment is in stable state.
4. The equipment can not have an obstacle at least in the range of 0.5 meters.
5. Do not replace the non-original parts.
5. Packing and Shipping
5.1 ATTACHMENT
Attach follow accessory.
Content Quantity
User Manual 1
DMX Cable 1
Safety Rope( charge) 1
MOVILED 105/4 User Manual/Manual de uso 3
EN

6. INSTALL STANDARD
Please ensure that make regular security checks for the lights and installation accessories.If lack
of these working conditions and professional level,
please let the relevant professional person do,
unprofessional incorrect operation can lead to life-threatening.
The equipment suitable environment temperature range is 0OC - 40OC, don’t use it in too high or
too low temperature. When the equipment is on installation, dismounting ,
removing or
repairing,please don't stay in the right below of the fixture . The operator must ensure that the
fixture is a secure connection. Please let professionals to check its electrical parameters before
installation. Make sure the related experts check
these installation once a year.
6.1 Rigging Installation
MOVILED 105/4 can put on the stage or install on the bracket in any direction, the rapid locking
system can lock it on the bracket fast and easily according to the following picture 2 direction.
6.2 EQUIPMENT FIXED
1. Before installation must verify the fast lock is keep in good state, and can withstand at least
10 times the weight of product. Verify that the building can withstand at least 10 times of
the total weight of the product and accessory equipments.
2.Use the bolt and Nuts of M12 lock the hooks and fixture.
MOVILED 105/4 User Manual/Manual de uso 4
EN

3. Fix the hang fixture into the hole, which located on the base of the light.
Seize handle of fasteners, clockwise rotate 1/4 turn and lock. Installed other one fastener in
the same method.
As the pictures show, the two square holes in the center of the base is the safety rope junction.
4. Using the safety cable which can withstand 10 times the weight of the equipment.
5. Make sure the X,Y protect locks are opened, Verify that within 0.5 meters there is no
combustibles .
6.3 EQUIPMENT CONNECT
Attention! One product only can accept one input and one output.
MOVILED 105/4 has DMX input and output 3pin and 5pin connection socket.
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin
3connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable.
MOVILED 105/4 User Manual/Manual de uso 5
EN

DMX 512 signal amplifier.
Do not use two outputs to separate the connection, if separate a continuous connection
to branch, DMX512 splitter is necessary.
Attention! vertically up to put the fixture, the shortest safe distance between the
fixtures must be≥900 mm, the installation layout diagram as shown in the picture.
To prevent the reflection and interference of receiving the control signals, we must
install a terminal plug at the end of each branch of 3pin or 5pin output socket. Terminal plug
(welding a 0.25W 120 Ω resistor between the 2 and 3 pin of 3pin or 5 pin socket.
6.4 CABLE CONNECTION
Connect the DMX data : from the controller to the near est controller equipment 3pin or 5pin
socket, and then from th is equipment output connected to the next equipment input, like this
continuous connecting, finally the output of the terminal equipment for the data cable insert a
terminal plug.
If use DMX512 distributor, the controller co nnect to the DMX512 distributor’ s input firstly,
then connect the next equipment from the output of the distributor, according to this method,
Finally match the terminal plug.
7. AC power..
7.1 VOLTAGE , FUSE SPECIFICATION
Input Voltage Fuse
200 -240V 5A 5×20(Main fuse)
100 -120V 10A 5×20(Main fuse)
MOVILED 105/4 User Manual/Manual de uso 6
EN

7.2 Power Connection
The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the device, and must have
an
overload or leakage electrical protection.
ATTENTION!
The equipment directly connected to the power supply.
Factory has equipped the standard 3 pin plug socket. Connect the power supply as below table.
Yellow and green wire could be connect to ground.
If the cable of the fixture is damaged, replacement should be operate by factory or qualified staff.
Wire Colour Plug Mark
Brown Live wire L
Blue Null N
Yellow+Green Ground wire
8. CONTROL PANEL MENU OPERATE
1: The indicating arrow in the right below is enter the menu (click the menu).
2: The touch screen display have four operation key : Exit, Upward, Downward, Enter, press it will
execute orders accordingly.
3: Can change the parameter Settings directly on the touch screen
4: Also can use the wheel on the left side of touch screen to change the parameter Settings
5: The equipment have built-in temperature sensor, the temperature will display on the bottom left
corner of touch screen. When over the rated temperature, the equipment will start the automatic
protection function.
6: When the equipment receive the DMX512 signal ,the blue ligh t on the top right lights up, the
left side show have connected the XLR Socket..
CONTROL PANEL MENU OPERATE
Address
DMX Address number set 001-512
Transfer Rate 029
Data 506
Signal quality 100%
Start Code 000
Fixed ID set 0-4096
Return
Special White Balance Off
MOVILED 105/4 User Manual/Manual de uso 7
EN

White Balance Red (0-100%)0 -255
White Balance Green (0-100%)0 -255
White Balance Blue (0-100%)0 -255
White Balance White (0-100%)0 -255
Dim Mode Fast
Slow
ChunMode
Smal
Stan
Exte
RunMode
DMX
Auto
Musc
SigClear Open
Off
Signal Reset Open
Off
Rainbow Exec
Annu
Return
InfoSee
Total Tim 00048:00
WorkHour 00000:03
Times 0000:61
ClearTim -- -- --
ClearTim -- -- -
Touch Screen_Control Vtft.01(Software version)
XY _Control (Software version )
LED _Control (Software version)
Return
Control
Channel 01 (25%) 64
Channel 02 (50%) 127
Channel 03 (100%) 255
... ... ... ... ... ...
Channel118 (25%) 64
Channel119 (50%) 127
Channel120 (100%) 255
Display
ShowReve Natu
Revl
Language Chin
Engh
BrigSett 0%-100%
Backligh Ligh
90s
MenuBack Off
MOVILED 105/4 User Manual/Manual de uso 8
EN

60s
Return
XY Setup
X Reverse Off
Open
Y Reverse Off
Open
XY Speed
Fast
NORM
Slow
X Angle 540°
360°
XY Fback Open
Off
Pan 0-255
Tilt 0-255
Focus 0-255
Return
9. Technical specification
product specification:
1: Power consumption
:150W
2: LED Quantity:7pcs 4 in 1 leds
(
RGBW)
3:
4:
2.8-inch touch screen display, Can be set up very intuitive personalization capabilities.
5:
Super quality lens
6:
Single Lens Angle: 5 degree
7:
Beam/Zoom Angle: 5 degrees, three linear motor adjust the lens angle.
8:
Control Mode:Simple mode, Standard mode, Extended mode
9:
Each led RGBW can be individual control 256 level of brightness control.
10:
With sound and master-slave mode control function
Many strobe and rainbow effect.
11:By using constant current control of each color, its brightness maintain on the same level no
matter in single fixture control or multiple fixtures control.
12:Pan scanning use 3phase motor
:540º 8Bit(16Bit scanning precision),
13:Tilt scanning use 3phase motor
:245º 8Bit(16Bit scanning precision),
14: Pan and Tilt adopt photoelectric reset system, can automatically inspect and reset,
15:DMX512 signal reception
16:Built-in temperature detection protection function.
MOVILED 105/4 User Manual/Manual de uso 9
EN
Indice
Lingue:
Altri manuali Mark Apparecchio di illuminazione
Manuali Apparecchio di illuminazione popolari di altre marche

Emos
Emos CLASSIC ZY1431T Manuale utente

Westinghouse
Westinghouse Outdoor Lighting Fixture Manuale utente

Hedler
Hedler C 12 silent Manuale utente

Blizzard Lighting
Blizzard Lighting Puck: CSI Manuale utente

Energetic Lighting
Energetic Lighting ELYSL-5004 Series Manuale utente

Lightmaxx
Lightmaxx Shaft 5R Manuale utente

Cooper Lighting
Cooper Lighting Halo L3232E Manuale utente

Stageline
Stageline ODW-2410RGBW Manuale utente

Light Sky
Light Sky Tornado Series Manuale utente

Lightolier
Lightolier Paralyte 2424 PLA2G9LS26U Manuale utente

Lightolier
Lightolier Lytespan 83ED17S Manuale utente

Lightolier
Lightolier Calculite CS8226 Manuale utente