Mark BEAM 201 Manuale utente

Rev. 13.03.01
BEAM 201
User Manual / Instrucciones de Usuario

STATEMENT
The product is good packing when ship out the factory. All users should strictly abide by the warnings and
nstructions stated in this manual, any damage and results due to misuse and the neglect of this operating
manual will be excluded from the deal responsibility this manual will not informed in additionally if have
technical changes.
DISPLAY PRODUCTION DESCRIPTION
Thank you for choose this B200 products, this model is the moving head light which is the latest
development of the smart, efficient products, beautiful shape, smooth R & D, combined with the advanced
technology of today's stage lighting products with international advanced electronic control technology and
excellent user-friendly industrial design , fully comply with CE standard, accepted international standard
DMX512 signal mode.
This moving head lights, use ceramic luminescent film reflector as a condenser system, coupled with the
high-quality optical lens components, broadband voltage, a clear pattern, sharp and uniform output light
efficiency. Intelligent LED display module, the English language selection mode, intuitive operating menu,
shortcut.
B200, have 16/20 international standard DMX512 channels optional Horizontal scan: 540 ° vertical
scanning 270 ° (16bit precision scanning) electronic correction, dot-matrix display, four touch switch LCD
+ single-Key flying shuttle can spin. The can be inverted 180 °, the color wheel is combined with white and
14 colors. Gobo wheel: 7 patterns + white effect round by eight prism and atomization function. 0-100%
mechanical dimmer, support mechanical strobe and variable strobe effect, strobe macro function. The
optical system of the lens group electric focusing, the beam angle of 0 to 4 ° with overheating protection
function.
Moving head lights are widely used in television, disco, dance halls, nightclubs, large-scale performances
and other professional venues
1. PRODUCT INTRODUCTION
Size:395(L)×287(W)×495(H)mm
Net Weight:17.5KG
2. SAFETY INFORMATION
Safety warning message
This product is only suitable for professional use, and does not apply to security for other purposes.
After you got the lights, please check the package whether have any damage caused by transportation.
If there is any damage, do not use this fixture, and please contact the dealer or
1.1 BEAM SIZE
BEAM 201 User Manual/Manual de uso Page 1
EN

Ta =40
manufacturer as soon as possible.
This product is only suitable for indoor, IP20 protection class. Lamps should be kept dry to avoid
Moisture, overheating or dusty environment. Prevent lamps come into contact with water or any
other liquid.
The use of this product should pay attention to: fire, heat, electric shock, ultraviolet radiation, the
lamp to explode or
Shedding caused serious or fatal injury.
Need to read the instructions before use energized or installing.
Follow through the operation of security methods and pay attention to the warning signs on the
specification and equipment. If you have any problem for how to safely operate the equipment.
Please contact your dealer.
Please don't use the equipment if the temperature above 40º C
The lens should be changed if had damaged or any problems. Don't change the
non-original manufacturer lens.
Len size:¢1136×60 mm
Please don't move the package by one person only.
When Hang the fixture, please must verify that the facilities to be able to withstand the weight
of the lamps at least 10 times more.
Please make sure the Mounting hardware is strong enough no any damage, and insurance
for the safety rope as auxiliary security fixed in other facilities will need to verify before
installation. Installing or removing the equipment, to make the pulley below the work location.
Prohibit straight viewpoint with exposed bulbs to avoid UV damage to the eyes;
Do not use the equipment without the lens screen and the lid;
2.1 ANTI-HIGH TEMPERATURE
2.2 BURST PREVENTION
2.3 TO PREVENT FALLING WOUNDING
2.4 UA PROTECTION AND THE BULB EXPLOSION
BEAM 201 User Manual/Manual de uso Page 2
EN

3. PACKAGE
ACCESSORY
CONTENT QUANTITY
1
1
HANG FIXTURE 2
SIGNAL CABLE 1
The lens and the light head covers should be timely replaced if any damage to rupture
The Fixture should be used with the protection screen together.
The electrical connection must only be carried out with corresponding qualifications;
Before installing, make sure you use the power voltage lamps must comply with the identified
power, voltage and have an overload or leakage protection;
Each lamp must be properly grounded, installed in accordance with the relevant standards;
Cut off the power when stall or replace the lamp and the fuse;
Prohibit the use of a lightning storm or wet environment.
1. Do not short-circuit temperature protection switch or fuse, use the specified type of fuse.
2. The equipment must be installed away from inflammable and explosive materials.
3. The equipment should be projected range of 3 meters away objects and projectiles
temperature less than 60 ° C; ---- 3.0m.
4. Fan or ventilation, at least in the range of 0.5 meters can not be an obstacle.
5. Do not place any object on the lens.
6. Handling at least allow the device to cool for 20 minutes.
7. Do not replace the non-original parts.
2.5 PREVENTION OF ELECTRIC SHOCK
2.6 TO PREVENT BURNING OR FIRE
3.1 ATTACHMENT
USER MANUAL
SAFETY ROPE
BEAM 201 User Manual/Manual de uso Page 3
EN

PACAKGE SIZE
FLY-CASE 2 IN 1 985*450*735
1. Before packed, make sure power is off, and wait for at least 20mins for cooling down.
2. Before clean the fixture, make sure X, Y axis protect lock closed.
3. After packed by plastic bag, high-lift the fixture with two handles besides the product. put
the product into the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the
fly-case.
5. Fly-case only up stacked two layers. Prohibited upside down
In order to protect the light, there is a protect lock; During the transport , the lock will closed
keeping the item in safety state.
Note: Before unpacking check the damage is whether due to the transportation or not, if
you find any such damage, please do not use this item, and contact with the dealer
or manufacturer as soon as possible.
1. Open the fly-case, and discover the inside plastic bag.
2. High-lift the product by two handles beside the bottom base and move it out.
3. Before power on, make sure you have opened the X, Y axis lock!
BEAM 201 can be placed on the stage, or mounted in an arbitrary direction of the truss. Two
fast locks system could fix the item easily
1. Before installation must verify the fast lock is keep in good state, and can withstand at least
10 times the weight of product. Verify that the truss can withstand at least 10 times of the
total weight of the product and accessory equipments.
2. Fix the hang fixture into the hole, which located on the base of the price.
Seize handle of fasteners, clockwise rotate 1/4 turn and lock. Installed other one fastener
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. INSTALL STANDARD
3.2 TRANSPORT PROTECT LOCK
3.3 ABOUT PACK STAGE
3.4 UNPACKING
4.1 INSTALL LOCK
4.2 EQUIPMENT FIXED
BEAM 201 User Manual/Manual de uso Page 4
EN

5. ALTERNATING CURRENT POWER SUPPLY
Input Voltage Total Power Frequency
110~240V 230W 50/60Hz
Fuse voltage Electronic current Specification
250V 6A 5×20
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. Make sure the X,Y protect locks are opened, Verify that within 3 meters there is no
combustibles .
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked! And only
fully clockwise rotate 90 ° can lock the hang fixture! Do remember plus a safety rope, and do
not connect the safety rope to plastic handle. It should be connect to the hole on the base!
Attention! One product only can accept one input one output.
BEAM 201 DMX cable include 3 contact pins:
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin 3
connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard
loudspeaker cable is not reliable to control the long-range data.
Attention! Do not overload the connection. One continuous connection can only connect
up to 32 devices.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to controller.
And then connected from the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with terminal insertion
4.3 FIXTURE CONNECT
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
BEAM 201 User Manual/Manual de uso Page 5
EN

The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the lamp, and must have
an overload or leakage electrical protection.
ATTENTION!
Factory has equipped the standard 3 pin plug socket. Connect the power supply as
below table.
If lamp cable is damaged, replacement should be operate by factory or qualified
staff. Any question, please contact professionals or talk to a qualified electrician.
Live wire(L) Null(N) Ground wire
RED BLUE Yellow +Green
6. LAMP
LAMP MODEL POWER OF LAMP LIFE/HOUR COLOR TEMPERATURE
Philips UHP 189 W 2200 HOURS 8000K
YODN 5R 200 W 2200 HOURS 8000K
YODN 7R 230W 2200 HOURS 8000K
WARNING! There is a safety hazard or damage if install similar bulb
To reduce the risk of damage to light ,do change the lamp before using
time over 125% of lamp life .
Attention! When replace the lamp is forbidden to touch lamp with bare hand, to
avoid the greasy dirt stains filament. filament must be kept clean
1. Disconnect the power. Before replace lamp, fixture need 20 minutes for lamp
cooling. Fasten the head with Y axis protect lock in 60 ° position.
2. Use cross screwdriver to open the light body cover, remove the fan bracket,
pull out the bulb cable
3. Open stainless steel tablet holder with one hand and the use other hand to
pull out the bulb at oblique 15 °
4. Install the lamp
6.2 LAMP REPLACE
6.1 LAMP DESCRIPTION
5.2 POWER PROTECT
BEAM 201 User Manual/Manual de uso Page 6
EN

7. CONTROL PANEL
A001
Rpan: X axis reverse
ON X axis reverse on
OFF X axis reverse off
Rtil: Y axis reverse
ON Y axis reverse on
OFF Y axis reverse off
POWER SIGNAL
LIGHT
DMX SIGNAL
LIGHT
DISPLAY SCREEN
BUTTON
DMX address: 001
Press E button to enter the DMX address set. Click "up" and
"down" button to adjust 0-255 address. Press "E" saved.
Click "up" button to enter this model, "E" button
confirm.
Click "up" & "down" button to adjust state. Press "E"
for confirm
Click "up" button to enter this model, "E" button
confirm.
Click "up" & "down" button to adjust state. Press "E"
for confirm
7.1 CONTROL PANEL INTRODUCTION
8.1. DMX ADDRESS AND X, Y AXIS CONTROL
8. BEAM 201 CONTROL
BEAM 201 User Manual/Manual de uso Page 7
EN

MODE CONTROL
DMX DMX MODE
DIS1:16CH
DIS2:20CH
DIS3: Advanced
AUTO AUTO
SOUD SOUND
DISP: DISPLAY MODE
MOD1:Display
MOD2:Dim display
MOD3:No display ( any button re-light)
Reverse display screen
LAMP:LAMP MODE
Click "up" button to enter this model, "E" button
confirm.
Click "up" & "down" button to adjust state. Press "E"
for confirm
Click "up" button to enter this model, "E" button
confirm.
Click "up" & "down" button to adjust state. Press "E"
for confirm
ON, press "E", turn on lamp by manual.
Show "OK?" and flash. Press "E", lamp
on when turn on light.
OFF, press "E", turn off lamp by manual.
Show "OK?" and flash. Press "E", lamp
off when turn on light.
8.2 MODE CONTROL
8.3 DISPLAY MODE
8.4 LAMP MODE
BEAM 201 User Manual/Manual de uso Page 8
EN

REST:RESET MODE Reset
All channel reset Press“E” , All reset
OPTO: OPTICAL COUPLE OPTICAL COUPLE ADJUST
ON Press“E” Adjust available
OFF Press“E” No adjust function
Channel DMX No Content
1CH Color 0-4 White
5-8 White+Color1
9-12 Color1
13-17 Color1+Color2
18-21 Color2
22-25 Color2+Color3
26-29 Color3
30-34 Color3+Color4
35-38 Color4
39-42 Color4+Color5
43-46 Color5
47-51 Color5+Color6
52-55 Color6
56-59 Color6+Color7
60-63 Color7
64-68 Color7+Color8
69-72 Color8
73-76 Color8+Color9
77-81 Color9
82-85 Color9+Color10
86-89 Color10
90-93 Color10+Color11
94-98 Color11
99-102 Color11+Color12
103-106 Color12
8.5 REST: RESET MODE
8.6 OPTO: OPTICAL COUPLE MODE
8.7 CHANNEL CONTROL
BEAM 201 User Manual/Manual de uso Page 9
EN
Indice
Lingue:
Altri manuali Mark Attrezzatura di illuminazione

Mark
Mark ECOLED Manuale utente

Mark
Mark Infra Mono 50-18 Guida utente

Mark
Mark SUPERPARLED ECO 18 Manuale utente

Mark
Mark MULTIPAR 575/2 Manuale utente

Mark
Mark PAR 36 ECO Manuale utente

Mark
Mark PAR-16 Manuale utente

Mark
Mark MBAR 4 72 BAT Manuale utente

Mark
Mark SUPERPARLED ECO 36 Manuale utente

Mark
Mark SIDIUS LED 368 Z Manuale utente

Mark
Mark SIDIUS ZOOM 555 Manuale utente