Mark beam 195 Manuale utente

Rev. 16.02.01
BEAM 195
User Manual / Instrucciones de Usuario


STATEMENT
The product is good packing when ship out the factory. All users should strictly abide by the warnings and
nstructions stated in this manual, any damage and results due to misuse and the neglect of this operating
manual will be excluded from the deal responsibility this manual will not informed in additionally if have
technical changes.
DISPLAY PRODUCTION DESCRIPTION
Thank you for choose this BEAM 195, this model is the moving head light which is the latest
development of the smart, efficient products, beautiful shape, smooth R & D, combined with the advanced
technology of today's stage lighting products with international advanced electronic control technology and
excellent user-friendly industrial design , fully comply with CE standard, accepted international standard
DMX512 signal mode.
This moving head lights, use ceramic luminescent film reflector as a condenser system, coupled with the
high-quality optical lens components, broadband voltage, a clear pattern, sharp and uniform output light
efficiency. Intelligent LED display module, the English language selection mode, intuitive operating menu,
shortcut.
BEAM 195, has 20 international standard DMX512 channels optional Horizontal scan: 540 ° vertical
scanning 270 ° (16bit precision scanning) electronic correction, LCD display and encoder for menu
Color wheel with 13 colors + spot, single rotation and rainbow effect.
Gobo wheel: 15 patterns + spot effect round by eight prism and atomization function. 0-100%
mechanical dimmer, support mechanical strobe and variable strobe effect, and frost function
Moving head lights are widely used in television, disco, dance halls, nightclubs, large-scale performances
and other professional venues
1. PRODUCT INTRODUCTION
Size:470(L)×330(W)×270(H)mm
Net Weight:11 Kg
2. SAFETY INFORMATION
Safety warning message
This product is only suitable for professional use, and does not apply to security for other purposes.
After you got the lights, please check the package whether have any damage caused by transportation.
If there is any damage, do not use this fixture, and please contact the dealer or
1.1 BEAM SIZE
BEAM 195 User Manual/Manual de uso Page 1
EN

Ta =40
manufacturer as soon as possible.
This product is only suitable for indoor, IP20 protection class. Lamps should be kept dry to avoid
Moisture, overheating or dusty environment. Prevent lamps come into contact with water or any
other liquid.
The use of this product should pay attention to: fire, heat, electric shock, ultraviolet radiation, the
lamp to explode or
Shedding caused serious or fatal injury.
Need to read the instructions before use energized or installing.
Follow through the operation of security methods and pay attention to the warning signs on the
specification and equipment. If you have any problem for how to safely operate the equipment.
Please contact your dealer.
Please don't use the equipment if the temperature above 40º C
The lens should be changed if had damaged or any problems. Don't change the
non-original manufacturer lens.
Len size:¢1136×60 mm
Please don't move the package by one person only.
When Hang the fixture, please must verify that the facilities to be able to withstand the weight
of the lamps at least 10 times more.
Please make sure the Mounting hardware is strong enough no any damage, and insurance
for the safety rope as auxiliary security fixed in other facilities will need to verify before
installation. Installing or removing the equipment, to make the pulley below the work location.
Prohibit straight viewpoint with exposed bulbs to avoid UV damage to the eyes;
Do not use the equipment without the lens screen and the lid;
2.1 ANTI-HIGH TEMPERATURE
2.2 BURST PREVENTION
2.3 TO PREVENT FALLING WOUNDING
2.4 UA PROTECTION AND THE BULB EXPLOSION
BEAM 195 User Manual/Manual de uso Page 2
EN

3. PACKAGE
ACCESSORY
CONTENT QUANTITY
1
1
HANG FIXTURE 2
S
SUPPLY CABLE
IGNAL CABLE 1
1
The lens and the light head covers should be timely replaced if any damage to rupture
The Fixture should be used with the protection screen together.
The electrical connection must only be carried out with corresponding qualifications;
Before installing, make sure you use the power voltage lamps must comply with the identified
power, voltage and have an overload or leakage protection;
Each lamp must be properly grounded, installed in accordance with the relevant standards;
Cut off the power when stall or replace the lamp and the fuse;
Prohibit the use of a lightning storm or wet environment.
1. Do not short-circuit temperature protection switch or fuse, use the specified type of fuse.
2. The equipment must be installed away from inflammable and explosive materials.
3. The equipment should be projected range of 3 meters away objects and projectiles
temperature less than 60 ° C; ---- 3.0m.
4. Fan or ventilation, at least in the range of 0.5 meters can not be an obstacle.
5. Do not place any object on the lens.
6. Handling at least allow the device to cool for 20 minutes.
7. Do not replace the non-original parts.
2.5 PREVENTION OF ELECTRIC SHOCK
2.6 TO PREVENT BURNING OR FIRE
3.1 ATTACHMENT
USER MANUAL
SAFETY ROPE
BEAM 195 User Manual/Manual de uso Page 3
EN

PACKAGING
Optional flightcase for 2 units
1. Before packed, make sure power is off, and wait for at least 20mins for cooling down.
2. Before clean the fixture, make sure X,Y axis protect lock closed.
3. After packed by plastic bag, high-lift the fixture with two handles besides the product. put
the product into the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the
fly-case.
5. Fly-case only up stacked two layers. Prohibited upside down
In order to protect the light, there is a protect lock; During the transport , the lock will closed
keeping the item in safety state.
Note: Before unpacking check the damage is whether due to the transportation or not, if
you find any such damage, please do not use this item, and contact with the dealer
or manufacturer as soon as possible.
1. Open the fly-case, and discover the inside plastic bag.
2. High-lift the product by two handles beside the bottom base and move it out.
3. Before power on, make sure you have opened the X, Y axis lock!
BEAM 195 can be placed on the stage, or mounted in an arbitrary direction of the truss.
Two fast locks system could fix the item easily
1. Before installation must verify the fast lock is keep in good state, and can withstand at least
10 times the weight of product. Verify that the truss can withstand at least 10 times of the
total weight of the product and accessory equipments.
2. Fix the hang fixture into the hole, which located on the base of the price.
Seize handle of fasteners, clockwise rotate 1/4 turn and lock. Installed other one fastener
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. INSTALL STANDARD
3.2 TRANSPORT PROTECT LOCK
3.3 ABOUT PACK STAGE
3.4 UNPACKING
4.1 INSTALL LOCK
4.2 EQUIPMENT FIXED
BEAM 195 User Manual/Manual de uso Page 4
EN

5. ALTERNATING CURRENT POWER SUPPLY
Input Voltage Total Power Frequency
110~240V 250W 50/60Hz
Fuse voltage Electronic current Specification
250V 6A 5×20
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. Make sure the X,Y protect locks are opened, Verify that within 3 meters there is no
combustibles .
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked! And only
fully clockwise rotate 90 ° can lock the hang fixture! Do remember plus a safety rope, and do
not connect the safety rope to plastic handle. It should be connect to the hole on the base!
Attention! One product only can accept one input one output.
BEAM 195 DMX cable include 3 contact pins:
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin 3
connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard
loudspeaker cable is not reliable to control the long-range data.
Attention! Do not overload the connection. One continuous connection can only connect
up to 32 devices.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to controller.
And then connected from the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with terminal insertion
4.3 FIXTURE CONNECT
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
BEAM 195 User Manual/Manual de uso Page 5
EN

The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the lamp, and must have
an overload or leakage electrical protection.
ATTENTION!
Factory has equipped the standard 3 pin plug socket. Connect the power supply as
below table.
If lamp cable is damaged, replacement should be operate by factory or qualified
staff. Any question, please contact professionals or talk toa qualified electrician.
Live wire(L) Null(N) Ground wire
RED BLUE Yellow +Green
6. LAMP
LAMP MODEL
5R 230W
WARNING! There is a safety hazard or damage if install similar bulb
To reduce the risk of damage to light ,do change the lamp before using
time over 125% of lamp life.
Attention! When replace the lamp is forbidden to touch lamp with bare hand, to
avoid the greasy dirt stains filament. filament must be kept clean
1. Disconnect the power. Before replace lamp, fixture need 20 minutes for lamp
cooling. Fasten the head with Y axis protect lock in 60 ° position.
2. Use cross screwdriver to open the light body cover, remove the fan bracket,
pull out the bulb cable
3. Open stainless steel tablet holder with one hand and the use other hand to
pull out the bulb at oblique 15 °
4. Install the lamp
6.2 LAMP REPLACE
6.1 LAMP DESCRIPTION
5.2 POWER PROTECT
BEAM 195 User Manual/Manual de uso Page 6
EN

7. CONTROL PANEL
7.1 CONTROL PANEL INTRODUCTION
BEAM 195 User Manual/Manual de uso Page 7
EN
01. Version:
brand, model, version, number, lamp use time
02 .Address: [001~512]
* Set DMX channel address
03. Pan reverse: [On/Off]
* On (reversed) Off (normal)
04. Tilt reverse: [On/Off]
* On (reversed) Off (normal)
0 5. Pan/Tilt speed: [ 01 -16 ]
*F rom 01 -16, to set the speed for Pan/Tilt movement
06. Pan/Tilt mode: [ 8bit /16bit ]
* 8bit, 16bit, when set as 8bit, the channels Pan fine and Tilt fine will be
disabled, the fixture has 14 channels now.
07. Lamp mode: [On/Off]
* On (lamp on); Off (lamp off)
08. Reset:
01. Lighting reset :
02. Lamp time restore: [ password ]
*Can be set password afterwards to prevent unwanted modifying)
03. Motor Zero:
[ password ]
*Restore (can be set password afterwards to prevent unwanted modifying)
04. Exit.

BEAM 195 User Manual/Manual de uso Page 8
EN
09. Channel data:
* When connected with a DMX controller, the channel value can not be
changed, only show channel DMX value. While there is no DMX controllers,
you can control the fixture by this item, select some channel, roll the
encoder wheel to adjust DMX value
09. Display:
1. Language :
* English
2. Backlight time:
*Open(always on ), 30 seconds
3. Back-brightness:
* 1 -4, from dark to bright
4. Exit:
Indice
Lingue: