MARS COMMERCE ZEUS4-VD Manuale utente

ZEUS4-VD
VOICE & SMS GSM ALARM
COMMUNICATOR
INSTALLATION MANUAL
V 2.0

ZEUS4-VD INSTALLATION MANUAL
TABLE OF CONTENTS
1FOR YOUR SAFETY................................................................................................................1
2INTRODUCTION......................................................................................................................2
3FEATURES AND APPLICATIONS .......................................................................................3
4START UP..................................................................................................................................4
5LED DISPLAY...........................................................................................................................5
6CLEAR ALL PROGRAMMED DATA FROM SIM.............................................................6
7CONNECTING DIAGRAM.....................................................................................................7
8VOICE MESSAGES –RECORD & PLAY............................................................................8
8.1 RECORDING MODE..............................................................................................................8
8.2 PLAY.......................................................................................................................................8
9PROGRAMMING MODE........................................................................................................9
9.1 PROGRAMMING TELEPHONE NUMBERS -TN...............................................................9
9.2 PROGRAMMING INPUT STATUS -IN..............................................................................10
9.1 INPUTS AND TELEPHONE NO. LINKING -LN...............................................................12
9.2 MAIN POWER LOST AND TELEPHONE NO. LINKING –LN5......................................13
9.3 LOW BATTERY AND TELEPHONE NO. LINKING –LN6..............................................13
9.4 MAIN POWER LOST FILTER PARAMETER -MAIN ......................................................14
9.5 INPUT FILTER PARAMETR –ID .......................................................................................15
9.6 DELAY BEFORE DIAL –DD ..............................................................................................16
9.7 PROGRAMMING OUTPUT STATUS -OS.........................................................................17
9.8 DIRECT ALARM OUTPUT –OD........................................................................................18
9.9 CLIP FUNCTION PARAMETER –TC ................................................................................19
9.1 AUTOMATIC INPUT BLOCK SYSTEM............................................................................20
9.2 SECURITY LEVEL -SL.......................................................................................................21
9.3 PREPAID CARD CREDIT AND VALIDITY INFORMATION..........................................22
9.4 SET-UP PARAMETERS.......................................................................................................22
9.5 SMS MESSAGES EDITOR ..................................................................................................25
10 DTMF REMOTE COMMANDS............................................................................................26
10.1 DTMF REMOTE COMMAND TABLE ...........................................................................26
11 PRINT-OUT OF THE PARAMETERS ................................................................................27
11.1 RECEIVE ALL PARAMETERS (PALL) .........................................................................27
11.2 RECEIVE TELEPHONE NUMBERS (PTN)....................................................................27
11.3 RECEIVE LINKS (PLN)...................................................................................................27
11.4 RECEIVE INPUT PARAMETERS (PIN).........................................................................27

ZEUS4-VD INSTALLATION MANUAL
11.5 RECEIVE INPUT FILTER VALUE (PID)........................................................................27
11.6 RECEIVE DELAY BEFORE DIAL VALUE (PDD)........................................................27
11.7 RECEIVE CLIP IDENTIFICATION FUNCTIONS (PTC) ..............................................27
11.8 RECEIVE ACCESS TELEPHONE NUMBERS (PSL) ....................................................28
11.9 RECEIVE OUTPUT PARAMETERS (POS)....................................................................28
11.10 RECEIVE LINK FOR LOCAL ALARM OUTPUT (POD) ..............................................28
11.11 RECEIVE ALL PROGRAMMED SMS MESSAGES (P#)...............................................28
11.12 RECEIVE THE POWER LEVEL ON THE UNIT (PPWR)..............................................28
11.13 RECEIVE SET UP PARAMETERS VALUE (PPA).........................................................28
11.14 STATE OF THE CREDIT FOR THE PREPAID CARD...................................................28
11.15 STATE OF THE OUTPUTS (PORC)................................................................................28
12 CHECKING AND CHANGING THE SYSTEM STATUS (ON/OFF)..............................29
12.1 CHECKING SYSTEM STATUS BY SMS COMMAND.................................................29
12.2 CHECKING SYSTEM STATUS BY DTMF COMMAND..............................................29
12.3 CHANGING SYSTEM STATUS TO ON (SYSTEM ON) ...............................................29
12.4 CHANGING SYSTEM STATUS TO OFF (SYSTEM OFF)............................................29
13 CHECKING THE INPUT STATUS......................................................................................30
13.1 CHECKING THE INPUT STATUS BY DTMF................................................................30
13.2 CHECKING THE INPUT STATUS BY SMS (INS).........................................................30
14 OUTPUTS REMOTE CONTROL.........................................................................................31
14.1 OUTPUTS REMOTE CONTROL BY SMS COMMAND ...............................................31
14.2 OUTPUTS REMOTE CONTROL BY DTMF COMMAND ............................................31
15 CHANGING PARAMETERS USING THE SMS COMMAND.........................................32
16 APPENDIX TO ZEUS4-VD MANUAL FOR CONTACT-ID (REV6) ..............................33
17 TECHNICAL SPECIFICATION...........................................................................................34
18 CONTACTS .............................................................................................................................35

ZEUS4-VD INSTALLATION MANUAL
1
1FOR YOUR SAFETY
Read these simple guidelines. Not following them may be dangerous or illegal. Read the complete
user guide for further information.
SWITCH ON SAFELY
Do not switch the unit on when use of wireless phone is prohibited or when it may cause
interference or danger.
INTERFERENCE
All wireless phones and units may be susceptible to interference, which could affect performance.
SWITCH OFF IN HOSPITALS
Follow any restrictions. Switch the unit off near medical equipment.
SWITCH OFF IN AIRCRAFT
Follow any restrictions. Wireless devices can cause interference in aircraft.
SWITCH OFF WHEN REFUELING
Do not use the unit at a refueling point. Do not use near fuel or chemicals.
SWITCH OFF NEAR BLASTING
Follow any restrictions. Do not use the unit where blasting is in progress.
USE SENSIBLY
Use only in the normal position as explained in the product documentation. Do not touch the
antenna unnecessarily.

ZEUS4-VD INSTALLATION MANUAL
2
2INTRODUCTION
ZEUS4-VD communicator is a new mobile voice and SMS autodialing system. It is mostly used to
provide wide range of alarm information and very useful remote controls. ZEUS4-VD can pass on
messages about intrusion alarms, technical alarms, etc. by voice call or SMS to the end-user or
directly by sending the Contact ID built-in to the Central Monitoring Station (CMS).
ZEUS4-VD can be used in connection with different applications such as:
Security alarm systems
Home care and Emergency alarm
Fire systems
Car and boat alarm transmitter
Door entry
Remote access control

ZEUS4-VD INSTALLATION MANUAL
3
3FEATURES AND APPLICATIONS
Features:
Built-in 3 or 4 band GSM module
Contact ID protocol built-in
4 alarm inputs
ON/OFF input
4 remotely controlled alarm outputs
4 prerecorded alarm messages –1 for each alarm input
15 SMS alarm and service messages
Memory stores up to 10 different telephone numbers
Listen-in function
PC programming by USB SIM card editor
Download programming by USB port
Output remotely controlled by SMS, CLIP and DTMF command
System activating and deactivating by SMS, CLIP and DTMF command
Up to 1000 event log buffer
Applications:
Security alarm systems
Home care and Emergency alarm
Fire systems
Car and boat alarm transmitter
Door entry
Remote access control
Temperature regulations
Vending Machines
Other remote controls

ZEUS4-VD INSTALLATION MANUAL
4
4START UP
Insert SIM card to be used for ZEUS4-VD in your personal mobile phone.
ERASE THE PIN CODE!
Enter telephone numbers and the required operating parameters in SIM memory –at least 1
telephone No. (TN1) and 1 link (LN1) should be programmed (see installation manual).
Insert SIM card in the GSM module applied for the ZEUS4-VD device. The unit must be
power OFF when you insert the SIM!
Connect alarm inputs and outputs to ZEUS4-VD.
Connect the antenna to antenna connector.
Connect device to source power supply voltage.
Wait until LED3 display is turned ON (green) and LED1 (blue) starts flashing. This is set in
around 1 minute.
Connect the headset to Play/REC connector and record alarm messages.
ZEUS4-VD unit is now ready to operate.
NOTE: When the back-up battery 12V/1,2Ah is connected to the unit the main power supply
must be from 13,8V to 14,5V DC!

ZEUS4-VD INSTALLATION MANUAL
5
5LED DISPLAY
Blue LED (LED1)
-Indicates the level of the GSM signal from 1 to 5 LED flashes (1 is weak signal, 5 is
excellent signal)
Red LED (LED2)
-When LED 2 is ON the unit has a problem with a GSM network connection or the GSM
part of the unit is out of order. In this case immediately call the service!
Red LED (LED2) –alarm state
-During an alarm event the red LED indicates on which input alarm has been triggered. For
example if alarm was triggered on the first input there is 1 LED flash, on second input 2
LED flashes, etc.
Green LED (LED3)
-When the alarm inputs on the unit are in active state (SYS=1) then the green LED is ON.
With alarm inputs disabled the green LED goes OFF (SYS=0).
Yellow LED (LED4)
-Short flashing indicates that the GSM module is ON, but it is not yet connected on the GSM
network. After connection, yellow led is flashing with short pulse ON and a long pulse OFF.

ZEUS4-VD INSTALLATION MANUAL
6
6CLEAR ALL PROGRAMMED DATA FROM SIM
WARNING!!! By sending this command to the ZEUS4-VD all programmed data are erased
from the SIM card!
This is highly recommended when a SIM card you are going to use for the ZEUS4-VD is not new
and it already has some data stored in the phone book memory.
By sending this SMS to ZEUS4-VD all programmed parameters and numbers are cleared:
;SDCLR;
After sending SMS you should wait at least 30 second for the command to be executed!

ZEUS4-VD INSTALLATION MANUAL
7
7CONNECTING DIAGRAM
Altri manuali per ZEUS4-VD
1
Indice
Altri manuali MARS COMMERCE Telefono cellulare



















